Americium
Experimental chemistry • properties • laboratory science
Am(III) typical; actinide separation and fluorescence chemistry.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 95 |
|---|---|
| Symbol / type | Am · Actinide • Solid at room temperature • atomic mass: [243] (indicative nuclide mass number; no standard atomic weight) |
| Elemental form | Solid | selected oxidation states +3,+4 |
| Chemical identity | Am(III) typical; actinide separation and fluorescence chemistry. |
| Occurrence and production | Produced by reactor fuel irradiation and decay processes. |
| Useful applications | Am-241 smoke detector sealed sources and specialist analysis. |
| Analytical characterization | Alpha spectrometry, gamma spectroscopy, radiochemical separations. |
| Research / quality note | Sealed detector source is not equivalent to an open americium sample. |
| Oxidation and chemical forms | Selected: +3 / +4. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 1449 K (1175.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 2284 K (2010.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | α-Am → β-Am: 1042 K; β-Am → γ-Am: 1350 K |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Radioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| α-Am (hexagonal close-packed family) | Solid (elemental baseline; named form stability can differ) | ≈1449 K(1175.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2284 K(2010.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Other reported β/γ americium solid phases | Solid (elemental baseline; named form stability can differ) | ≈1449 K(1175.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2284 K(2010.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Am-241 | 432.2 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1449 K(1175.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2284 K(2010.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Am-243 | 7,350 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1449 K(1175.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2284 K(2010.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | No stable isotopes; representative radioactive form: Am-241. Isotope, source activity and daughter products must be identified. |
|---|---|
| External radiation — near-term | External: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: Am-241 emits alpha plus low-energy photons; glass blocks alpha but not necessarily all photons. |
| External radiation — longer-term | External: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae. |
| Internal exposure — near-term | Internal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. Internal americium can irradiate lungs, bone and liver; biokinetics depend on compound. |
| Internal exposure — longer-term | Internal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution. |
| Nuclear assessment note | Radiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 19 recorded: 231, 232, 233, 234, 235, 236, 237, 238, 239, 240, 241, 242, 243, 244, 245, 246, 247, 248, 249. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Uncertain | [GREY - unclassified] A contaminated surface may feel ordinary; alpha-emitting material and photons require a dose/contamination survey. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Uncertain | [GREY - unclassified] No reliable immediate skin symptoms; contaminating alpha-emitter particles and penetrating photons require assessment. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Critical | Inhaled americium particles can cause internal exposure without initial illness. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Chronic dose to bone/liver/lung and cancer risk depend on isotope and uptake. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Uncertain | [GREY - unclassified] Americium metal tarnishes/oxidizes in air; form and isotope determine radiological significance. | Interpret together with storage, ignition and process conditions. |
| Water contact | Uncertain | [GREY - unclassified] Metal aqueous reactivity is condition-dependent and incompletely standardized; water can mobilize compounds. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Uncertain | For unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade. | Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist. |
| Eye exposure | Uncertain | For unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade. | Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist. |
| Skin absorption | Uncertain | For unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade. | Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Uncertain | Heated radioactive material may create airborne contamination plus radionuclide-dependent external dose; no generic rating. | Licensed specialized containment and integrated radiological/chemical review. CONDITION: Depends on isotope, activity, form. |
| Chemical incompatibility | Uncertain | Compatibility is isotope/chemical-form specific; radiological contamination can make ordinary acid/oxidizer reactions hazardous. | Only approved radiochemical procedures with compatibility analysis. CONDITION: Do not infer from elemental name alone. |
| Storage and pressure | Uncertain | Sealed-source certification, activity, contamination control, gas ingrowth and decay products can govern storage; no generic safe glass arrangement. | Radiation safety officer, source registry, security and engineered containment. CONDITION: Isotope/activity and sealed status required. |
| Bioaccumulation | Uncertain | For unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade. | Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist. |
| Reproductive/developmental effects | Uncertain | For unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade. | Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist. |
| Environmental effects | Uncertain | Environmental persistence, internal dose and hazard depend on isotope activity, chemical form, decay chain and transport pathways. | Follow radiation permits, monitored effluent and radioactive-waste management. CONDITION: No safe-disposal inference from half-life. |
| Cryogenic effects | Uncertain | No routine cryogenic elemental handling basis; if cryogenic materials are used, risks are process-specific plus radiological. | Specialist hazard analysis required. CONDITION: Unknown outside engineered research systems. |
| Mechanical and pressure hazards | Uncertain | No universal mechanical-handling grade for specialist radioactive material; engineered containment governs. | Use licensed handling system and impact-resistant containment. CONDITION: Quantity/form dependent. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Licensed radiochemistry / nuclear facility — Isotope, activity, dose and contamination must be reviewed by radiation-protection staff. |
|---|---|
| Research objective | Interpret americium-241 source certificates or spectra |
| Expected observation / output | Activity, emission lines, uncertainty. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Authorized isotope-defined source or sealed certified reference, not unspecified “element” material. |
| Sample preparation & apparatus | Licensed shielding/containment, isotope assay, dose-rate and contamination monitoring, RSO authorization. |
| Atmosphere and compatibility | Containment selected by activity, chemical form and isotope; do not infer safe air conditions from element name. |
| Production / refining context | Production and purification are license-restricted; discuss source specification and isotope certification rather than recipes. |
| Reaction, oxidation & corrosion | Am(III) typical; actinide separation and fluorescence chemistry. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Activity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended. |
| Electrical / magnetic / optical measurement | Alpha spectrometry, gamma spectroscopy, radiochemical separations. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Sealed detector source is not equivalent to an open americium sample. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Am sources are engineered radioactive devices, not simple element specimens. |
| Teaching / research levels | School: non-contact educational spectra. University: published data/approved simulated datasets. Research: licensed isotope-specific procedures. |
| Preservation & data archive | Registered isotope-specific licensed inventory with source integrity, contamination, shielding and expiration review. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T4 • licensed radioactive-material facility; RSO approval required |
|---|---|
| Practical experiment question | Interpret americium-241 source certificates or spectra. |
| Measurable evidence | Activity, emission lines, uncertainty. Specified radionuclide/activity or isotope ratio (not just element symbol). |
| Measurement pathway (candidate) | Licensed radiometry; isotope-specific assay; matrix chemistry where authorized. |
| Specimen & interpretation boundary | Am sources are engineered radioactive devices, not simple element specimens. |
| Known failure/false conclusion | Decay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing. |
| Evidence required BEFORE use | IAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Curium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: