ELEMENT 097 / ACTINIDE
97BkATOMIC NUMBER · SYMBOL

Berkelium

Experimental chemistry • properties • laboratory science

Bk(III)/Bk(IV) redox, short-lived synthetic element.

Atomic no. 97ActinideSolid at room conditions
Explore profile
IMAGE PLACEHOLDERBkReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number97
Symbol / typeBk · Actinide • Solid at room temperature • atomic mass: [247] (indicative nuclide mass number; no standard atomic weight)
Elemental formSolid | selected oxidation states +3,+4
Chemical identityBk(III)/Bk(IV) redox, short-lived synthetic element.
Occurrence and productionHigh-flux reactor/accelerator production in tiny amounts.
Useful applicationsActinide research and target preparation for new elements.
Analytical characterizationMicrochemical separations and radiometric detection.
Research / quality noteNo commercial elemental bulk applications; isotope production is bottleneck.
Oxidation and chemical formsSelected: +3 / +4. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)1323 K (1049.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)?
Sublimation (solid → gas) near 1 atm?
Additional solid–solid transitionsα-Bk → β-Bk: 1250 K
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationRadioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-Bk (hexagonal close-packed family)Solid (elemental baseline; named form stability can differ)≈1323 K(1049.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)?
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Lower-temperature reported metal phase. LAB: Extremely rare radiological sample.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1323 K; gas transition unknown. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-Bk (fcc)Solid (elemental baseline; named form stability can differ)≈1323 K(1049.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)?
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Higher-temperature phase; transition reported near 1250 K. LAB: No standard instructional specimen. [AL3]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1323 K; gas transition unknown. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 1250 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Bk-2471,380 ySolid (expected elemental chemical form, not isotope-specific observation)≈1323 K(1049.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)?
Full record, evidence, conditions & photographs
Decay or evidence note
alpha
Approximate solid / liquid / gas ranges
Elemental-reference fusion near ~1323 K; gas boundary not established. This is not a validated phase diagram for the isotope.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisNo stable isotopes; representative radioactive form: Bk-249. Isotope, source activity and daughter products must be identified.
External radiation — near-termExternal: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: Bk-249 is radioactive and used only in specialist research; radiation fields depend on isotope and daughters.
External radiation — longer-termExternal: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae.
Internal exposure — near-termInternal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. Potential internal dose exists from contamination, but human exposure data are sparse.
Internal exposure — longer-termInternal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution.
Nuclear assessment noteRadiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates.

Isotope mass-number inventory (reference registry; not complete ENSDF): 20 recorded: 235, 236, 237, 238, 239, 240, 241, 242, 243, 244, 245, 246, 247, 248, 249, 250, 251, 252, 253, 254. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateUncertain[GREY - unclassified] Only specialist quantities exist; no normal skin-contact toxicity dataset.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedUncertain[GREY - unclassified] No normal direct contact or repeated contact database; contamination protection mandatory.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateUncertain[GREY - unclassified] Only specialized research quantities; inhalation would cause internal radiation exposure.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedUncertain[GREY - unclassified] Not enough human data to quantify chronic effects; isotope/activity/dose must be modeled.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityUncertain[GREY - unclassified] Berkelium is produced in very small quantities; routine bulk metal-air tests are not established.Interpret together with storage, ignition and process conditions.
Water contactUncertain[GREY - unclassified] No routine experimentally established bulk metal-water reaction classification.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionUncertainFor unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade.Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist.
Eye exposureUncertainFor unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade.Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist.
Skin absorptionUncertainFor unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade.Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesUncertainHeated radioactive material may create airborne contamination plus radionuclide-dependent external dose; no generic rating.Licensed specialized containment and integrated radiological/chemical review. CONDITION: Depends on isotope, activity, form.
Chemical incompatibilityUncertainCompatibility is isotope/chemical-form specific; radiological contamination can make ordinary acid/oxidizer reactions hazardous.Only approved radiochemical procedures with compatibility analysis. CONDITION: Do not infer from elemental name alone.
Storage and pressureUncertainSealed-source certification, activity, contamination control, gas ingrowth and decay products can govern storage; no generic safe glass arrangement.Radiation safety officer, source registry, security and engineered containment. CONDITION: Isotope/activity and sealed status required.
BioaccumulationUncertainFor unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade.Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist.
Reproductive/developmental effectsUncertainFor unsealed material, chemical behavior and internal irradiation are isotope-, activity- and compound-dependent; no defensible generic health grade.Radiation protection assessment, contamination control, intake monitoring and approved nuclear laboratory procedures. CONDITION: Radioactive specimen; chemical and internal dose routes coexist.
Environmental effectsUncertainEnvironmental persistence, internal dose and hazard depend on isotope activity, chemical form, decay chain and transport pathways.Follow radiation permits, monitored effluent and radioactive-waste management. CONDITION: No safe-disposal inference from half-life.
Cryogenic effectsUncertainNo routine cryogenic elemental handling basis; if cryogenic materials are used, risks are process-specific plus radiological.Specialist hazard analysis required. CONDITION: Unknown outside engineered research systems.
Mechanical and pressure hazardsUncertainNo universal mechanical-handling grade for specialist radioactive material; engineered containment governs.Use licensed handling system and impact-resistant containment. CONDITION: Quantity/form dependent.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierLicensed radiochemistry / nuclear facility — Isotope, activity, dose and contamination must be reviewed by radiation-protection staff.
Research objectiveEvaluate berkelium nuclear-chemistry evidence from tracer studies
Expected observation / outputDecay signatures and chemical separation factors. Predetermine units, calibration basis and appropriate control.
Available physical formAuthorized isotope-defined source or sealed certified reference, not unspecified “element” material.
Sample preparation & apparatusLicensed shielding/containment, isotope assay, dose-rate and contamination monitoring, RSO authorization.
Atmosphere and compatibilityContainment selected by activity, chemical form and isotope; do not infer safe air conditions from element name.
Production / refining contextProduction and purification are license-restricted; discuss source specification and isotope certification rather than recipes.
Reaction, oxidation & corrosionBk(III)/Bk(IV) redox, short-lived synthetic element. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseActivity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended.
Electrical / magnetic / optical measurementMicrochemical separations and radiometric detection. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationNo commercial elemental bulk applications; isotope production is bottleneck. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallOnly specialist microquantities.
Teaching / research levelsSchool: non-contact educational spectra. University: published data/approved simulated datasets. Research: licensed isotope-specific procedures.
Preservation & data archiveRegistered isotope-specific licensed inventory with source integrity, contamination, shielding and expiration review.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT4 • licensed radioactive-material facility; RSO approval required
Practical experiment questionEvaluate berkelium nuclear-chemistry evidence from tracer studies.
Measurable evidenceDecay signatures and chemical separation factors. Specified radionuclide/activity or isotope ratio (not just element symbol).
Measurement pathway (candidate)Licensed radiometry; isotope-specific assay; matrix chemistry where authorized.
Specimen & interpretation boundaryOnly specialist microquantities.
Known failure/false conclusionDecay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing.
Evidence required BEFORE useIAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteCalifornium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: