Fermium
Experimental chemistry • properties • laboratory science
Synthetic radioactive actinide, trivalent chemistry expected/observed in traces.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 100 |
|---|---|
| Symbol / type | Fm · Actinide • No measured bulk sample at room temperature • atomic mass: [257] (indicative nuclide mass number; no standard atomic weight) |
| Elemental form | No measured bulk sample | selected oxidation states Specialist data |
| Chemical identity | Synthetic radioactive actinide, trivalent chemistry expected/observed in traces. |
| Occurrence and production | Produced by multiple neutron captures and decay chains. |
| Useful applications | Nuclear chemistry research only. |
| Analytical characterization | Radiochemical separation and decay spectroscopy. |
| Research / quality note | No meaningful bulk thermophysical measurements. |
| Oxidation and chemical forms | Not a routinely measured bulk property; oxidation-state reports need original experimental evidence. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 1125 K (851.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | ? |
| Sublimation (solid → gas) near 1 atm | ? |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Radioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈1125 K(851.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Fm-257 | 100.5 d | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1125 K(851.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | No stable isotopes; representative radioactive form: Fm-257. Isotope, source activity and daughter products must be identified. |
|---|---|
| External radiation — near-term | External: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. |
| External radiation — longer-term | External: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae. |
| Internal exposure — near-term | Internal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. |
| Internal exposure — longer-term | Internal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution. |
| Nuclear assessment note | Radiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 19 recorded: 242, 243, 244, 245, 246, 247, 248, 249, 250, 251, 252, 253, 254, 255, 256, 257, 258, 259, 260. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Uncertain | [GREY - unclassified] Only highly specialized quantities exist; no typical touch scenario. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Uncertain | [GREY - unclassified] No routine macroscopic sample; radiation contamination is the relevant issue. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Uncertain | [GREY - unclassified] No normal laboratory aerosol exposure outside specialized nuclear research. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Uncertain | [GREY - unclassified] No evidence base for chronic human exposure; assess nuclear dose, not predicted chemical symptoms. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Uncertain | [GREY - unclassified] Fermium is known from extremely small radioactive quantities; bulk air-reaction behavior is not established. | Interpret together with storage, ignition and process conditions. |
| Water contact | Uncertain | [GREY - unclassified] No experimental bulk metal-water data suitable for a hazard table. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Eye exposure | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Skin absorption | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Fire and explosion | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Heating and fumes | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Chemical incompatibility | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Storage and pressure | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Bioaccumulation | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Reproductive/developmental effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Environmental effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Cryogenic effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Mechanical and pressure hazards | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Specialist ultratrace facility — Ordinary bulk experiments impossible or inappropriate; analysis of records only. |
|---|---|
| Research objective | Interpret fermium atom-scale nuclear data |
| Expected observation / output | Decay chain, nuclide identity. Predetermine units, calibration basis and appropriate control. |
| Available physical form | No routine visible elemental specimen; published tracer/isotope measurement or certified record. |
| Sample preparation & apparatus | Specialist isotope-separation instrument and radiometric detection; no transferable open-bench protocol. |
| Atmosphere and compatibility | Containment selected by activity, chemical form and isotope; do not infer safe air conditions from element name. |
| Production / refining context | Specialist radioactive tracer preparation. Report chemical separation factor only when supported by a licensed protocol. |
| Reaction, oxidation & corrosion | Synthetic radioactive actinide, trivalent chemistry expected/observed in traces. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Activity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended. |
| Electrical / magnetic / optical measurement | Radiochemical separation and decay spectroscopy Report tracer/atom-scale inference only; never imply bulk-sample measurement. |
| Quantification & verification | No meaningful bulk thermophysical measurements. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | No realistic macroscopic experimentation. |
| Teaching / research levels | School: spectra/photos/verified published data only. University: supervised nuclear-data analysis. Research: authorized atom-scale experiment. |
| Preservation & data archive | Research documentation and authorized nuclear inventory only; no routine storage of bulk elemental specimen. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T5 • no routine macroscopic elemental specimen; specialist isotope facility only |
|---|---|
| Practical experiment question | Interpret fermium atom-scale nuclear data. |
| Measurable evidence | Decay chain, nuclide identity. Nuclide-specific activity/decay evidence. |
| Measurement pathway (candidate) | Published specialized tracer or decay records. |
| Specimen & interpretation boundary | No realistic macroscopic experimentation. |
| Known failure/false conclusion | Decay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing. |
| Evidence required BEFORE use | IAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Mendelevium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: