ELEMENT 087 / ALKALI METAL
87FrATOMIC NUMBER · SYMBOL

Francium

Experimental chemistry • properties • laboratory science

Extremely rare radioactive alkali metal; only very small atom populations prepared.

Atomic no. 87Alkali metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERFrReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number87
Symbol / typeFr · Alkali metal • No measured bulk sample at room temperature • atomic mass: [223] (indicative nuclide mass number; no standard atomic weight)
Elemental formNo measured bulk sample | selected oxidation states +1
Chemical identityExtremely rare radioactive alkali metal; only very small atom populations prepared.
Occurrence and productionMade in nuclear reactions/decay chains; no macroscopic isolated sample.
Useful applicationsAtomic structure and weak-interaction physics research.
Analytical characterizationLaser trapping and spectroscopy of atoms.
Research / quality noteNo industrial chemistry or routine sample-based measurement is possible.
Oxidation and chemical formsNot a routinely measured bulk property; oxidation-state reports need original experimental evidence.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)≈294 K (20.85 °C) (published secondary estimate, not measured)
Elemental-bulk boiling / gas formation (near 1 atm)≈923 K (649.85 °C) (published secondary estimate, not measured)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationRSC tabulated estimates; no verified macroscopic elemental francium phase boundary. Melting close to room temperature, state classification depends on convention.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈294 K(20.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form)≈923 K(649.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
No macroscopic elemental francium sample or experimentally characterized crystal-allotrope inventory exists. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~294 K; generic gas reference ~923 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
Published elemental estimate — NOT form-specific
Phase data source
https://periodic-table.rsc.org/element/87/francium
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Fr-22322.0 minSolid (expected elemental chemical form, not isotope-specific observation)≈294 K(20.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form)≈923 K(649.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~294 K; liquid between ~294 and ~923 K; gas above ~923 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
Published elemental estimate — NOT isotope-specific
Isotope phase source
https://periodic-table.rsc.org/element/87/francium
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisNo stable isotopes; representative radioactive form: Fr-223. Isotope, source activity and daughter products must be identified.
External radiation — near-termExternal: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: Francium isotopes are short-lived and not available as macroscopic elemental samples.
External radiation — longer-termExternal: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae.
Internal exposure — near-termInternal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. No typical human intake scenario; assess isotope activity and decay products only at specialist facilities.
Internal exposure — longer-termInternal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution.
Nuclear assessment noteRadiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates.

Isotope mass-number inventory (reference registry; not complete ENSDF): 34 recorded: 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 232. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateUncertain[GREY - unclassified] No macroscopic solid sample exists for routine skin contact.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedUncertain[GREY - unclassified] No ordinary macroscopic sample or skin-exposure scenario exists.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateUncertain[GREY - unclassified] No ordinary inhalation scenario; any produced radioactive atoms require specialized containment.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedUncertain[GREY - unclassified] No routine chronic occupational dataset; activity and very short half-lives dominate research controls.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityUncertain[GREY - unclassified] Francium exists only in tiny transient amounts; bulk metal exposure-to-air behavior is not observed.Interpret together with storage, ignition and process conditions.
Water contactUncertain[GREY - unclassified] No experimentally characterized bulk francium-water reaction; alkali-metal analogy is a prediction, not a bench observation.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Eye exposureUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Skin absorptionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Fire and explosionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Heating and fumesUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Chemical incompatibilityUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Storage and pressureUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
BioaccumulationUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Reproductive/developmental effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Environmental effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Cryogenic effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Mechanical and pressure hazardsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSpecialist ultratrace facility — Ordinary bulk experiments impossible or inappropriate; analysis of records only.
Research objectiveInterpret francium laser-trapping evidence in published data
Expected observation / outputOptical frequency and atom-count record. Predetermine units, calibration basis and appropriate control.
Available physical formNo routine visible elemental specimen; published tracer/isotope measurement or certified record.
Sample preparation & apparatusSpecialist isotope-separation instrument and radiometric detection; no transferable open-bench protocol.
Atmosphere and compatibilityContainment selected by activity, chemical form and isotope; do not infer safe air conditions from element name.
Production / refining contextSpecialist radioactive tracer preparation. Report chemical separation factor only when supported by a licensed protocol.
Reaction, oxidation & corrosionExtremely rare radioactive alkali metal; only very small atom populations prepared. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseActivity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended.
Electrical / magnetic / optical measurementLaser trapping and spectroscopy of atoms Report tracer/atom-scale inference only; never imply bulk-sample measurement.
Quantification & verificationNo industrial chemistry or routine sample-based measurement is possible. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallOnly ultratrace atoms; bulk specimen unavailable.
Teaching / research levelsSchool: spectra/photos/verified published data only. University: supervised nuclear-data analysis. Research: authorized atom-scale experiment.
Preservation & data archiveResearch documentation and authorized nuclear inventory only; no routine storage of bulk elemental specimen.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT5 • no routine macroscopic elemental specimen; specialist isotope facility only
Practical experiment questionInterpret francium laser-trapping evidence in published data.
Measurable evidenceOptical frequency and atom-count record. Nuclide-specific activity/decay evidence.
Measurement pathway (candidate)Published specialized tracer or decay records.
Specimen & interpretation boundaryOnly ultratrace atoms; bulk specimen unavailable.
Known failure/false conclusionDecay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing.
Evidence required BEFORE useIAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteRadium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: