Gallium
Experimental chemistry • properties • laboratory science
Low melting metal; Ga(III); compounds GaAs/GaN are important electronic materials.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 31 |
|---|---|
| Symbol / type | Ga · p-block/post-transition element • Solid at room temperature • atomic mass: 69.723 (rounded) |
| Elemental form | Solid | selected oxidation states +3 |
| Chemical identity | Low melting metal; Ga(III); compounds GaAs/GaN are important electronic materials. |
| Occurrence and production | Byproduct of bauxite/zinc processing, highly purified for semiconductors. |
| Useful applications | GaN power electronics, GaAs optoelectronics and low-melt alloys. |
| Analytical characterization | ICP-MS for impurities; SIMS/Hall for doped semiconductors; XRD. |
| Research / quality note | Ga can embrittle Al; GaAs device properties are not those of metallic Ga. |
| Bench properties | Approx. melting 29.8 °C; density 5.91 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +3. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 302.9146 K (29.76 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 2673 K (2399.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | Metastable β, γ, δ, ε Ga phases have distinct melting points |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| α-Ga (orthorhombic) | Stable α-Ga solid at 20 °C and ~1 atm | 302.9146 K(α-Ga) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| β-Ga (monoclinic) | Metastable β-Ga is not the stable 20 °C solid; reported β fusion ~256.9 K | 256.9 K(β-Ga, metastable) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| γ-Ga, δ-Ga, ε-Ga | Solid (elemental baseline; named form stability can differ) | γ-Ga ~237.6 K; δ-Ga ~253.8 K; ε-Ga ~244.6 K (metastable form-specific values) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Compressed gallium | Solid (elemental baseline; named form stability can differ) | ≈302.9146 K(29.76 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | Selected evaluated transitions at ~1 atm (NIST TN 2312): α melting = 302.915 K. These are phase boundaries, not safe heating instructions. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Ga-67 | 3.26 d | Solid (expected elemental chemical form, not isotope-specific observation) | ≈302.9146 K(29.76 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ga-69 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈302.9146 K(29.76 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ga-71 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈302.9146 K(29.76 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2673 K(2399.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Ga-67. The BLUE entries refer ONLY to stable nuclides, not to Ga-67. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 31 recorded: 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Metal usually low skin hazard; may stain/react with metals. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Very low | No established chronic dermal toxicity for pure gallium metal; prolonged contact with alloys or compounds differs. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Moderate | Airborne elemental gallium is unlikely at room temperature; aerosols may irritate, and evidence is limited. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Moderate | Insufficient human data for long-term inhalation of elemental gallium; organometallics require separate assessment. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Low | Gallium has a surface oxide film in air; bulk metal is reasonably stable under ambient conditions. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | No vigorous reaction with ordinary water; oxide/solution chemistry matters in acids or alkalis. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Moderate | Ingestion of elemental particles is not a validated safe exposure; toxicity depends on solubility, amount, particle size and transformations in stomach acid. | Prevent hand-to-mouth exposure; use elemental-form SDS for any incident. CONDITION: Screening level only. |
| Eye exposure | Moderate | Solid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal. | Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity. |
| Skin absorption | Low | No established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure. | Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Moderate | Environmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient. | Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Verify gallium metal phase near ambient temperature |
| Expected observation / output | DSC melt transition and surface inspection. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Clean sample mount and correctly calibrated method selected from the target observable; confirm holder compatibility. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Byproduct of bauxite/zinc processing, highly purified for semiconductors. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Low melting metal; Ga(III); compounds GaAs/GaN are important electronic materials. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 29.8 °C and density 5.91 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | ICP-MS for impurities; SIMS/Hall for doped semiconductors; XRD. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Ga can embrittle Al; GaAs device properties are not those of metallic Ga. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Gallium damages aluminium; specimen vessel compatibility matters. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Verify gallium metal phase near ambient temperature. |
| Measurable evidence | DSC melt transition and surface inspection. Specified total element concentration, crystal phase or surface chemistry. |
| Measurement pathway (candidate) | XRF/ICP-OES/ICP-MS for composition; XRD or surface assay only if needed. |
| Specimen & interpretation boundary | Gallium damages aluminium; specimen vessel compatibility matters. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Germanium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: