ELEMENT 067 / LANTHANIDE
67HoATOMIC NUMBER · SYMBOL

Holmium

Experimental chemistry • properties • laboratory science

Ho(III) strong magnetic moment and narrow optical lines.

Atomic no. 67LanthanideSolid at room conditions
Explore profile
IMAGE PLACEHOLDERHoReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number67
Symbol / typeHo · Lanthanide • Solid at room temperature • atomic mass: 164.930 (rounded)
Elemental formSolid | selected oxidation states +3
Chemical identityHo(III) strong magnetic moment and narrow optical lines.
Occurrence and productionHeavy rare-earth ores, separation.
Useful applicationsHo:YAG medical lasers, calibration spectra and magnetic research.
Analytical characterizationICP-MS; emission/absorption spectroscopy; magnetometry.
Research / quality noteLaser action comes from doped host crystal, not a block of Ho metal.
Oxidation and chemical formsSelected: +3. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)1742 K (1468.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)2873 K (2599.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈1742 K(1468.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2873 K(2599.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Holmium is hcp in the ordinary bulk form; multiple magnetic phases are not necessarily distinct crystal allotropes. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1742 K; generic gas reference ~2873 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Ho-165Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1742 K(1468.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2873 K(2599.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1742 K; liquid between ~1742 and ~2873 K; gas above ~2873 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Ho-16626.8 hSolid (expected elemental chemical form, not isotope-specific observation)≈1742 K(1468.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2873 K(2599.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1742 K; liquid between ~1742 and ~2873 K; gas above ~2873 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Ho-166. The BLUE entries refer ONLY to stable nuclides, not to Ho-166.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 36 recorded: 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateLowBulk low acute data/irritant.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedLowRepeated holmium powder contact may irritate; intact metal has limited evidence of systemic absorption.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighFine particles may cause coughing; avoid generating airborne dust.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedHighInsufficient chronic inhalation data for pure holmium; evaluate relevant compounds separately.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighHolmium gradually oxidizes on exposed surfaces; powder reacts more readily.Interpret together with storage, ignition and process conditions.
Water contactModerateBulk metal shows slow water corrosion rather than vigorous hydrogen release.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateElemental particles and any products formed in stomach acid have poorly characterized oral bioavailability; avoid assuming innocuousness.Prohibit ingestion; verify form-specific toxicology for actual process. CONDITION: Rare-earth salts and oxides are different materials.
Eye exposureModeratePowder can produce mechanical irritation; fine reactive particles can change in moist tissues.Avoid dust and eye contact; use safety eyewear. CONDITION: Bulk metal is less mobile than powder.
Skin absorptionLowDermal uptake of bulk rare-earth metal is not established as a major route; powders may irritate or chemically change on moist skin.Minimize skin contamination; review powder properties. CONDITION: Elemental metal vs salts.
Fire and explosionHighFine metal particles may burn vigorously; dust clouds may explode under processing conditions.Avoid dust accumulation and ignition; assess combustibility before milling. CONDITION: Applies to sufficient airborne dust mass, not sealed cube.
Heating and fumesModerateHeating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity.Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes.
Chemical incompatibilityModerateStrong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case.Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix.
Storage and pressureModerateLoose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk.Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass.
BioaccumulationUncertainHuman biokinetics of bulk elemental rare-earth particles are limited; soluble salts/oxides have different disposition.Use material-specific data rather than a blanket bioaccumulation claim. CONDITION: Evidence insufficient.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsUncertainElemental rare-earth environmental toxicity depends on oxidation, dissolution, organism, soil chemistry and co-contaminants; data incomplete.Collect waste; avoid release to drains/soil; use speciation tests if needed. CONDITION: Uncertainty, not presumed safety.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSchool observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate.
Research objectiveVerify holmium optical absorption references
Expected observation / outputAbsorption wavelength and uncertainty. Predetermine units, calibration basis and appropriate control.
Available physical formSpecify metal versus oxide/dopant/host compound; oxidation of bulk metal affects interpretation.
Sample preparation & apparatusCompatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable.
Atmosphere and compatibilityDocument oxide growth; inert/dry atmosphere often needed for clean elemental surface testing.
Production / refining contextOccurrence/production context: Heavy rare-earth ores, separation. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionHo(III) strong magnetic moment and narrow optical lines. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseSelect temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes.
Electrical / magnetic / optical measurementICP-MS; emission/absorption spectroscopy; magnetometry. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationLaser action comes from doped host crystal, not a block of Ho metal. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallHo compounds are often used as wavelength standards.
Teaching / research levelsSchool: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study.
Preservation & data archiveProtect air-sensitive elemental surface; separate labeled metal specimens from oxides and host compounds.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT1/T2 • supervised accessible specimen when form-specific risk assessment permits
Practical experiment questionVerify holmium optical absorption references.
Measurable evidenceAbsorption wavelength and uncertainty. Total element content and phase (separate questions).
Measurement pathway (candidate)ICP-MS/ICP-OES with XRD for oxide/alloy phase.
Specimen & interpretation boundaryHo compounds are often used as wavelength standards.
Known failure/false conclusionOxide-to-metal substitution; isobaric/molecular ion interference in ICP-MS; line crowding.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteErbium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: