Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 71 |
|---|---|
| Symbol / type | Lu · Lanthanide • Solid at room temperature • atomic mass: 174.967 (rounded) |
| Elemental form | Solid | selected oxidation states +3 |
| Chemical identity | Lu(III), smallest lanthanide ion; dense scintillator hosts. |
| Occurrence and production | Rare-earth concentrates; difficult close-element separation. |
| Useful applications | Lu-based PET scintillators and radiopharmaceutical Lu-177 compounds. |
| Analytical characterization | ICP-MS; scintillation decay measurements; radio-HPLC for Lu-177 drugs. |
| Research / quality note | Stable lutetium and Lu-177 must be reported separately; Lu-177 is a radioisotope. |
| Oxidation and chemical forms | Selected: +3. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 1950 K (1676.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 3675 K (3401.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Lu-175 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Lu-176 | ~37.6 billion y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Lu-177 | 6.65 d | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Naturally occurring material may contain low-activity radionuclide(s); example Lu-176 / Lu-177. Many laboratory-enriched/activated forms are different. |
|---|---|
| External radiation — near-term | Typical small natural-composition samples are not expected to cause prompt external radiation injury; this is NOT a clearance for concentrated or activated material. Specific example: Lu-176 contributes natural radioactivity; Lu-177 used medically emits beta and some gamma radiation. |
| External radiation — longer-term | Cumulative external dose is usually low for ordinary samples but may need assessment for unusual amounts or radioisotope-enriched materials. |
| Internal exposure — near-term | Natural radionuclides may enter the body with dust, gases or soluble materials. Immediate radiologic symptoms are not expected at background-level intake; chemical toxicity may be separate. Radiopharmaceutical Lu-177 bio-distribution depends on the attached molecule; do not generalize to bulk lutetium. |
| Internal exposure — longer-term | Radiation-induced effects depend on committed organ dose and retention, not merely the element name; higher intakes can increase long-term cancer risk. |
| Nuclear assessment note | NUCLEAR STATUS: Naturally occurring radioisotopes are known or may have extremely long decay half-lives. Never infer “stable” solely from natural abundance. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 35 recorded: 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Bulk low acute toxicity data. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Low | Repeated lutetium dust can irritate; radioactive Lu isotopes add contact-contamination issues. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | High | Particles may irritate or deliver isotope-dependent radiation if radioactive. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | High | Insufficient chronic toxicology for lutetium metal dust; Lu-177 medical exposures are a different setting. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Lutetium is relatively resistant in dry air; prolonged exposure may form oxide. | Interpret together with storage, ignition and process conditions. |
| Water contact | Moderate | Bulk metal does not normally react vigorously with cold water; any corrosion is slow. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Moderate | Elemental particles and any products formed in stomach acid have poorly characterized oral bioavailability; avoid assuming innocuousness. | Prohibit ingestion; verify form-specific toxicology for actual process. CONDITION: Rare-earth salts and oxides are different materials. |
| Eye exposure | Moderate | Powder can produce mechanical irritation; fine reactive particles can change in moist tissues. | Avoid dust and eye contact; use safety eyewear. CONDITION: Bulk metal is less mobile than powder. |
| Skin absorption | Low | Dermal uptake of bulk rare-earth metal is not established as a major route; powders may irritate or chemically change on moist skin. | Minimize skin contamination; review powder properties. CONDITION: Elemental metal vs salts. |
| Fire and explosion | High | Fine metal particles may burn vigorously; dust clouds may explode under processing conditions. | Avoid dust accumulation and ignition; assess combustibility before milling. CONDITION: Applies to sufficient airborne dust mass, not sealed cube. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Moderate | Loose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk. | Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass. |
| Bioaccumulation | Uncertain | Human biokinetics of bulk elemental rare-earth particles are limited; soluble salts/oxides have different disposition. | Use material-specific data rather than a blanket bioaccumulation claim. CONDITION: Evidence insufficient. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Uncertain | Elemental rare-earth environmental toxicity depends on oxidation, dissolution, organism, soil chemistry and co-contaminants; data incomplete. | Collect waste; avoid release to drains/soil; use speciation tests if needed. CONDITION: Uncertainty, not presumed safety. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Analyze lutetium in detector crystals or catalysts |
| Expected observation / output | Lu assay and crystal structure. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specify metal versus oxide/dopant/host compound; oxidation of bulk metal affects interpretation. |
| Sample preparation & apparatus | Compatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable. |
| Atmosphere and compatibility | Document oxide growth; inert/dry atmosphere often needed for clean elemental surface testing. |
| Production / refining context | Occurrence/production context: Rare-earth concentrates; difficult close-element separation. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Lu(III), smallest lanthanide ion; dense scintillator hosts. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Select temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes. |
| Electrical / magnetic / optical measurement | ICP-MS; scintillation decay measurements; radio-HPLC for Lu-177 drugs. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Stable lutetium and Lu-177 must be reported separately; Lu-177 is a radioisotope. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Lu scintillator is a compound; isotope choice may matter. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Protect air-sensitive elemental surface; separate labeled metal specimens from oxides and host compounds. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Analyze lutetium in detector crystals or catalysts. |
| Measurable evidence | Lu assay and crystal structure. Total element content and phase (separate questions). |
| Measurement pathway (candidate) | ICP-MS/ICP-OES with XRD for oxide/alloy phase. |
| Specimen & interpretation boundary | Lu scintillator is a compound; isotope choice may matter. |
| Known failure/false conclusion | Oxide-to-metal substitution; isobaric/molecular ion interference in ICP-MS; line crowding. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Hafnium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: