ELEMENT 071 / LANTHANIDE
71LuATOMIC NUMBER · SYMBOL

Lutetium

Experimental chemistry • properties • laboratory science

Lu(III), smallest lanthanide ion; dense scintillator hosts.

Atomic no. 71LanthanideSolid at room conditions
Explore profile
IMAGE PLACEHOLDERLuReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number71
Symbol / typeLu · Lanthanide • Solid at room temperature • atomic mass: 174.967 (rounded)
Elemental formSolid | selected oxidation states +3
Chemical identityLu(III), smallest lanthanide ion; dense scintillator hosts.
Occurrence and productionRare-earth concentrates; difficult close-element separation.
Useful applicationsLu-based PET scintillators and radiopharmaceutical Lu-177 compounds.
Analytical characterizationICP-MS; scintillation decay measurements; radio-HPLC for Lu-177 drugs.
Research / quality noteStable lutetium and Lu-177 must be reported separately; Lu-177 is a radioisotope.
Oxidation and chemical formsSelected: +3. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)1950 K (1676.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)3675 K (3401.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Lutetium is hcp in the ordinary bulk crystalline form. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1950 K; generic gas reference ~3675 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Lu-175Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1950 K; liquid between ~1950 and ~3675 K; gas above ~3675 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Lu-176~37.6 billion ySolid (expected elemental chemical form, not isotope-specific observation)≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1950 K; liquid between ~1950 and ~3675 K; gas above ~3675 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Lu-1776.65 dSolid (expected elemental chemical form, not isotope-specific observation)≈1950 K(1676.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈3675 K(3401.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1950 K; liquid between ~1950 and ~3675 K; gas above ~3675 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisNaturally occurring material may contain low-activity radionuclide(s); example Lu-176 / Lu-177. Many laboratory-enriched/activated forms are different.
External radiation — near-termTypical small natural-composition samples are not expected to cause prompt external radiation injury; this is NOT a clearance for concentrated or activated material. Specific example: Lu-176 contributes natural radioactivity; Lu-177 used medically emits beta and some gamma radiation.
External radiation — longer-termCumulative external dose is usually low for ordinary samples but may need assessment for unusual amounts or radioisotope-enriched materials.
Internal exposure — near-termNatural radionuclides may enter the body with dust, gases or soluble materials. Immediate radiologic symptoms are not expected at background-level intake; chemical toxicity may be separate. Radiopharmaceutical Lu-177 bio-distribution depends on the attached molecule; do not generalize to bulk lutetium.
Internal exposure — longer-termRadiation-induced effects depend on committed organ dose and retention, not merely the element name; higher intakes can increase long-term cancer risk.
Nuclear assessment noteNUCLEAR STATUS: Naturally occurring radioisotopes are known or may have extremely long decay half-lives. Never infer “stable” solely from natural abundance.

Isotope mass-number inventory (reference registry; not complete ENSDF): 35 recorded: 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateVery lowBulk low acute toxicity data.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedLowRepeated lutetium dust can irritate; radioactive Lu isotopes add contact-contamination issues.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighParticles may irritate or deliver isotope-dependent radiation if radioactive.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedHighInsufficient chronic toxicology for lutetium metal dust; Lu-177 medical exposures are a different setting.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighLutetium is relatively resistant in dry air; prolonged exposure may form oxide.Interpret together with storage, ignition and process conditions.
Water contactModerateBulk metal does not normally react vigorously with cold water; any corrosion is slow.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateElemental particles and any products formed in stomach acid have poorly characterized oral bioavailability; avoid assuming innocuousness.Prohibit ingestion; verify form-specific toxicology for actual process. CONDITION: Rare-earth salts and oxides are different materials.
Eye exposureModeratePowder can produce mechanical irritation; fine reactive particles can change in moist tissues.Avoid dust and eye contact; use safety eyewear. CONDITION: Bulk metal is less mobile than powder.
Skin absorptionLowDermal uptake of bulk rare-earth metal is not established as a major route; powders may irritate or chemically change on moist skin.Minimize skin contamination; review powder properties. CONDITION: Elemental metal vs salts.
Fire and explosionHighFine metal particles may burn vigorously; dust clouds may explode under processing conditions.Avoid dust accumulation and ignition; assess combustibility before milling. CONDITION: Applies to sufficient airborne dust mass, not sealed cube.
Heating and fumesModerateHeating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity.Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes.
Chemical incompatibilityModerateStrong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case.Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix.
Storage and pressureModerateLoose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk.Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass.
BioaccumulationUncertainHuman biokinetics of bulk elemental rare-earth particles are limited; soluble salts/oxides have different disposition.Use material-specific data rather than a blanket bioaccumulation claim. CONDITION: Evidence insufficient.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsUncertainElemental rare-earth environmental toxicity depends on oxidation, dissolution, organism, soil chemistry and co-contaminants; data incomplete.Collect waste; avoid release to drains/soil; use speciation tests if needed. CONDITION: Uncertainty, not presumed safety.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSchool observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate.
Research objectiveAnalyze lutetium in detector crystals or catalysts
Expected observation / outputLu assay and crystal structure. Predetermine units, calibration basis and appropriate control.
Available physical formSpecify metal versus oxide/dopant/host compound; oxidation of bulk metal affects interpretation.
Sample preparation & apparatusCompatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable.
Atmosphere and compatibilityDocument oxide growth; inert/dry atmosphere often needed for clean elemental surface testing.
Production / refining contextOccurrence/production context: Rare-earth concentrates; difficult close-element separation. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionLu(III), smallest lanthanide ion; dense scintillator hosts. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseSelect temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes.
Electrical / magnetic / optical measurementICP-MS; scintillation decay measurements; radio-HPLC for Lu-177 drugs. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationStable lutetium and Lu-177 must be reported separately; Lu-177 is a radioisotope. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallLu scintillator is a compound; isotope choice may matter.
Teaching / research levelsSchool: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study.
Preservation & data archiveProtect air-sensitive elemental surface; separate labeled metal specimens from oxides and host compounds.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT1/T2 • supervised accessible specimen when form-specific risk assessment permits
Practical experiment questionAnalyze lutetium in detector crystals or catalysts.
Measurable evidenceLu assay and crystal structure. Total element content and phase (separate questions).
Measurement pathway (candidate)ICP-MS/ICP-OES with XRD for oxide/alloy phase.
Specimen & interpretation boundaryLu scintillator is a compound; isotope choice may matter.
Known failure/false conclusionOxide-to-metal substitution; isobaric/molecular ion interference in ICP-MS; line crowding.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteHafnium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: