Nickel
Experimental chemistry • properties • laboratory science
Ni(II)/Ni(0) catalysis; passivating alloys; corrosion behavior depends on medium.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 28 |
|---|---|
| Symbol / type | Ni · Transition metal • Solid at room temperature • atomic mass: 58.693 (rounded) |
| Elemental form | Solid | selected oxidation states +2,+3 |
| Chemical identity | Ni(II)/Ni(0) catalysis; passivating alloys; corrosion behavior depends on medium. |
| Occurrence and production | Sulfide/laterite ores; matte refining/electrowinning. |
| Useful applications | Stainless steel, batteries, catalysts and superalloys. |
| Analytical characterization | XRF/OES for alloys; electrochemistry for corrosion; ICP for trace Ni. |
| Research / quality note | Nickel sensitization and volatile nickel carbonyl are not equivalent hazards. |
| Bench properties | Approx. melting 1455 °C; density 8.91 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +2 / +3. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 1729 K (1455.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 3003 K (2729.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Ni-58 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ni-60 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ni-61 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ni-62 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ni-63 | 100 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Ni-64 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1729 K(1455.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3003 K(2729.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Ni-63. The BLUE entries refer ONLY to stable nuclides, not to Ni-63. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 31 recorded: 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | High | Brief touch may cause no immediate symptoms; nickel-allergic individuals may develop an itchy rash hours later. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Critical | Repeated contact frequently causes allergic nickel dermatitis that can persist or recur. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | High | Nickel dust/fumes may irritate or cause airway sensitization; severity depends on compound. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Chronic occupational exposure to certain nickel compounds is associated with lung/nasal cancers; metal may also cause asthma. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Moderate | Nickel is comparatively air-stable with a protective surface; powder may burn and heated operations produce fumes. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | No significant cold-water reaction for bulk nickel. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Moderate | Elemental particles may cause gastrointestinal or systemic effects after sufficient intake; soluble compounds generally have distinct absorption. | Prevent accidental swallowing; review SDS for particle size and chemistry. CONDITION: Do not infer effects from soluble salts. |
| Eye exposure | Moderate | Dust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms. | Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye. |
| Skin absorption | Moderate | Repeated particulate contact can cause dermatitis or sensitization; inhalation is often a more serious exposure route. | Avoid dust on skin; use appropriate gloves and skin hygiene. CONDITION: Metal allergen and oxide-specific issues vary. |
| Fire and explosion | Moderate | Combustible-dust potential increases in finely divided or heated form; clean bulk material is generally less readily ignited. | Check actual powder combustibility; control ignition and dust. CONDITION: Conditional on particle size and process. |
| Heating and fumes | High | Heating can generate irritating or toxic oxide/metal fumes; hazards are greater than from cold intact metal. | Local exhaust and process-specific exposure assessment. CONDITION: Metal and formed oxide should be assessed separately. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Moderate | Loose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk. | Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass. |
| Bioaccumulation | Moderate | These elements may be present in normal physiology or retained after overexposure; harmful loading depends on dose and chemical form. | Avoid chronic excess exposure; assess blood/urine/tissue measurements only when indicated. CONDITION: Essential nutrient status does not mean safe unlimited intake. |
| Reproductive/developmental effects | Uncertain | Reproductive effects reported for some metal compounds/high exposures; evidence is insufficient for a general rating of ordinary elemental solid. | Check substance-form reproductive data and institutional occupational health guidance. CONDITION: Uncertain form-specific risk. |
| Environmental effects | High | Releases of metal particles or soluble products can threaten aquatic or terrestrial organisms; toxicity depends on speciation and dose. | Contain wastewater and particulate residues; follow waste regulations. CONDITION: Never assume elemental metal dissolves at salt-like rates. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Test nickel plating corrosion and surface composition |
| Expected observation / output | Coating thickness, electrochemical signal. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Clean sample mount and correctly calibrated method selected from the target observable; confirm holder compatibility. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Sulfide/laterite ores; matte refining/electrowinning. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Ni(II)/Ni(0) catalysis; passivating alloys; corrosion behavior depends on medium. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 1455 °C and density 8.91 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | XRF/OES for alloys; electrochemistry for corrosion; ICP for trace Ni. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Nickel sensitization and volatile nickel carbonyl are not equivalent hazards. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Surface layers and Ni sensitization affect material selection. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Test nickel plating corrosion and surface composition. |
| Measurable evidence | Coating thickness, electrochemical signal. Composition versus phase/surface/performance—choose one first. |
| Measurement pathway (candidate) | XRF/OES for bulk assay; XRD/XPS for phase or surface; 4-probe where relevant. |
| Specimen & interpretation boundary | Surface layers and Ni sensitization affect material selection. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Copper |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: