ELEMENT 118 / NOBLE GAS
118OgATOMIC NUMBER · SYMBOL

Oganesson

Experimental chemistry • properties • laboratory science

Heaviest confirmed element; proposed noble-gas analogy has major relativistic uncertainties.

Atomic no. 118Noble gasNot established at room conditions
Explore profile
IMAGE PLACEHOLDEROgReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number118
Symbol / typeOg · Noble gas • No measured bulk sample at room temperature • atomic mass: [294] (indicative nuclide mass number; no standard atomic weight)
Elemental formNo measured bulk sample | selected oxidation states Research / predicted
Chemical identityHeaviest confirmed element; proposed noble-gas analogy has major relativistic uncertainties.
Occurrence and productionCreated in heavy-ion collision experiments at tiny yield.
Useful applicationsNuclear structure and fundamental physics only.
Analytical characterizationRecoil separators and decay correlations.
Research / quality noteNo macroscopic state, melting point, density or accessible chemical use is established.
Oxidation and chemical formsNot a routinely measured bulk property; oxidation-state reports need original experimental evidence.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmHypothetical solid at 20 °C (theoretical prediction; no macroscopic sample)
Elemental-bulk melting / freezing (near 1 atm)≈325 ± 15 K (theoretical prediction)
Elemental-bulk boiling / gas formation (near 1 atm)≈450 ± 10 K (theoretical prediction)
Sublimation (solid → gas) near 1 atm?
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsHypothetical macroscopic elemental sample, ~1 atm in model; NOT experimentally obtainable
Data qualificationNormal-pressure bulk melting not established in this evaluated extraction; see form-specific data. Theoretical model: Relativistic quantum-chemical predictions for hypothetical macroscopic elemental Og; cannot be validated as a bulk experiment with current half-lives. Source: https://doi.org/10.1002/anie.202011976

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Bulk allotropy not experimentally establishedHypothetical solid at 20 °C (theoretical prediction; no macroscopic sample) (elemental baseline; named form stability can differ)≈325 ± 15 K(theoretical published estimate; hypothetical bulk sample, NOT isotope/form-specific)≈450 ± 10 K(theoretical published estimate; hypothetical bulk sample, NOT isotope/form-specific)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
No measured macroscopic elemental crystal phases are available; isotope lifetimes and production methods restrict direct bulk characterization. LAB: Any proposed solid structure, density, phase transition or lattice parameter should be labeled calculated rather than experimentally confirmed.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~325 K; generic gas reference ~450 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
Published bulk estimate/theory (NOT form-specific)
Phase data source
https://doi.org/10.1002/anie.202011976
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2] (no macroscopic phase dataset available). Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Og-2940.7 msHypothetical solid at 20 °C (theoretical prediction; no macroscopic sample) (expected elemental chemical form, not isotope-specific observation)≈325 ± 15 K(theoretical published estimate; hypothetical bulk sample, NOT isotope/form-specific)≈450 ± 10 K(theoretical published estimate; hypothetical bulk sample, NOT isotope/form-specific)
Full record, evidence, conditions & photographs
Decay or evidence note
alpha
Approximate solid / liquid / gas ranges
THEORETICAL hypothetical bulk ranges at ~1 atm: solid below ~325 K; liquid between ~325 and ~450 K; gas above ~450 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
Published bulk estimate/theory (NOT isotope-specific)
Isotope phase source
https://doi.org/10.1002/anie.202011976
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisNo stable nuclides; short-lived Og isotopes. Only atom-scale research production; macroscopic touch or inhalation is not a realistic ordinary lab exposure.
External radiation — near-termNo ordinary macroscopic source or measured human acute-dose scenario. Ionizing emissions exist at atom scale; no safe distance or personal risk can be inferred.
External radiation — longer-termNo meaningful chronic human cohort data. An exposure assessment would require actual atoms/activity, decay products, instrument background and geometry.
Internal exposure — near-termOrdinary inhalation of this element is not a credible routine scenario. No human acute inhalation-effect evidence.
Internal exposure — longer-termNo established chronic inhalation effects from bulk material because no bulk sample exists; theoretical radiological risk is not a clinical observation.
Nuclear assessment noteRadiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates.

Isotope mass-number inventory (reference registry; not complete ENSDF): 3 recorded: 293, 294, 295. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateUncertain[GREY - unclassified] Only atom-scale, short-lived research material exists; no ordinary macroscopic contact scenario.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedUncertain[GREY - unclassified] Only short-lived atom-scale research samples; cannot normally touch a bulk element.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateUncertain[GREY - unclassified] No ordinary inhalation scenario; specialized detection/containment applies.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedUncertain[GREY - unclassified] No human chronic data or practical macroscopic sample.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityUncertain[GREY - unclassified] Oganesson has no macroscopic sample; ordinary air stability/reactivity is unknown.Interpret together with storage, ignition and process conditions.
Water contactUncertain[GREY - unclassified] No measured bulk water reaction; noble-gas analogies are unreliable without testing.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Eye exposureUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Skin absorptionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Fire and explosionUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Heating and fumesUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Chemical incompatibilityUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Storage and pressureUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
BioaccumulationUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Reproductive/developmental effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Environmental effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Cryogenic effectsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
Mechanical and pressure hazardsUncertainData not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions.Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierAccelerator / atom-at-a-time research — No preparable macroscopic sample; interpret qualified published observations only.
Research objectiveInterpret oganesson nuclide production and detection
Expected observation / outputRecoil correlations and confidence interval. Predetermine units, calibration basis and appropriate control.
Available physical formNot a bulk specimen: recoil/decay-tagged individual atoms in a specialized facility.
Sample preparation & apparatusHeavy-ion accelerator, recoil separator and alpha-decay detectors; custom calibrated event correlation.
Atmosphere and compatibilityNo normal atmosphere or container: few-atom experiment under beamline vacuum/controlled carrier gas.
Production / refining contextProduced as fleeting atoms in specialized accelerator runs; “purification yield” is not bulk chemical yield.
Reaction, oxidation & corrosionOnly decay-tagged chemistry or transport/adsorption evidence may exist; do not infer macroscopic corrosion, electrical, or magnetic behavior.
Temperature, pressure & phaseBeam energy, target, separator settings and nuclide half-life are facility-specific; no bulk pressure/temperature curve.
Electrical / magnetic / optical measurementRecoil separators and decay correlations Report tracer/atom-scale inference only; never imply bulk-sample measurement.
Quantification & verificationNo macroscopic state, melting point, density or accessible chemical use is established. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallNoble-gas analogy is uncertain; no bulk sample.
Teaching / research levelsSchool: spectra/photos/verified published data only. University: supervised nuclear-data analysis. Research: authorized atom-scale experiment.
Preservation & data archiveNo storable bulk sample; archive detector raw data, calibration, experiment metadata and decay-chain evidence.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT5 • atom-at-a-time research; published datasets only for ordinary readers
Practical experiment questionInterpret oganesson nuclide production and detection.
Measurable evidenceRecoil correlations and confidence interval. Nuclide identification; correlated event counts (NOT bulk chemistry).
Measurement pathway (candidate)Decay-tagged accelerator/nuclide records.
Specimen & interpretation boundaryNoble-gas analogy is uncertain; no bulk sample.
Known failure/false conclusionSparse event statistics; background coincidences; identification confidence; no bulk extrapolation.
Evidence required BEFORE useFacility primary papers + nuclide evaluations; avoid chemical property claims from periodic trends.
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: