ELEMENT 076 / TRANSITION METAL
76OsATOMIC NUMBER · SYMBOL

Osmium

Experimental chemistry • properties • laboratory science

Dense platinum-group metal; Os(VIII) tetroxide is a strong oxidizer.

Atomic no. 76Transition metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDEROsReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number76
Symbol / typeOs · Transition metal • Solid at room temperature • atomic mass: 190.230 (rounded)
Elemental formSolid | selected oxidation states +2,+3,+4,+8
Chemical identityDense platinum-group metal; Os(VIII) tetroxide is a strong oxidizer.
Occurrence and productionRecovered from platinum-group ore streams.
Useful applicationsSpecialty hard alloys and osmium tetroxide microscopy chemistry.
Analytical characterizationICP-MS for Os; species-selective analysis where OsO4 may form.
Research / quality noteOsO4 is highly hazardous and is not a property of clean metallic Os alone.
Oxidation and chemical formsSelected: +2 / +3 / +4 / +8. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)3328 K (3054.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)5285 K (5011.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Osmium is hcp in the ordinary bulk metal. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~3328 K; generic gas reference ~5285 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Os-184Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-186Natural; possible extremely long-lived radioactivitySolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Verify ENSDF
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-187Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-188Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-189Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-190Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-19115.4 dSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Os-192Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3328 K(3054.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5285 K(5011.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3328 K; liquid between ~3328 and ~5285 K; gas above ~5285 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Os-191. The BLUE entries refer ONLY to stable nuclides, not to Os-191.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.
Nuclear assessment noteNUCLEAR STATUS: Naturally occurring radioisotopes are known or may have extremely long decay half-lives. Never infer “stable” solely from natural abundance.

Isotope mass-number inventory (reference registry; not complete ENSDF): 35 recorded: 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateLowBulk metal contact less dangerous than its tetroxide.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedModerateRepeated osmium metal contact usually has low acute effect; osmium tetroxide contaminant is highly dangerous.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighBulk metal dust may irritate; osmium tetroxide vapor can severely injure eyes and lungs.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalPersistent eye/respiratory injury may follow tetroxide exposure; not an intrinsic effect of touching clean osmium metal.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityCriticalOsmium metal is comparatively stable in room-temperature air, but heating/strong oxidation can generate volatile, highly toxic OsO4.Interpret together with storage, ignition and process conditions.
Water contactVery lowNo normal reaction of bulk osmium with water.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateIngestion of elemental particles is not a validated safe exposure; toxicity depends on solubility, amount, particle size and transformations in stomach acid.Prevent hand-to-mouth exposure; use elemental-form SDS for any incident. CONDITION: Screening level only.
Eye exposureModerateSolid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal.Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity.
Skin absorptionLowNo established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure.Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesCriticalHeating or oxidizing osmium can generate toxic osmium tetroxide, which can cause severe eye and respiratory effects.Specialized containment, incompatible oxidizer segregation and no open heating. CONDITION: Product OsO4 is a compound, not elemental metal.
Chemical incompatibilityModerateStrong oxidizers may convert osmium to hazardous volatile osmium tetroxide.Separate oxidizers; avoid open treatment and heating. CONDITION: Hazard stems from reaction product.
Storage and pressureLowA closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible.Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsModerateEnvironmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient.Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsModerateDense or heavy metal pieces can cause impact/crush injury if dropped; machining produces sharp swarf.Secure mounts and lifting procedures; avoid loose shavings. CONDITION: Physical hazard not a claim of high intrinsic chemical toxicity.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierProfessional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment.
Research objectiveMeasure osmium-containing specimens indirectly via certified analysis
Expected observation / outputOs assay and oxidation-state report. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound.
Sample preparation & apparatusEnclosed instrument or preprepared certified reference; exposure and waste control are prerequisites.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextContext: Recovered from platinum-group ore streams. For teaching, use certified prepared materials; industrial extraction is not a bench recipe.
Reaction, oxidation & corrosionDense platinum-group metal; Os(VIII) tetroxide is a strong oxidizer. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseSelect temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes.
Electrical / magnetic / optical measurementICP-MS for Os; species-selective analysis where OsO4 may form. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationOsO4 is highly hazardous and is not a property of clean metallic Os alone. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallFormation of highly toxic OsO4 requires special control.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveCertified containment and segregated inventory with contamination monitoring and disposal protocol.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • specialized controlled professional facility; no open handling
Practical experiment questionMeasure osmium-containing specimens indirectly via certified analysis.
Measurable evidenceOs assay and oxidation-state report. Trace/major element concentration in specified matrix.
Measurement pathway (candidate)Certified solid or solution CRM by ICP-MS/XRF as matrix permits.
Specimen & interpretation boundaryFormation of highly toxic OsO4 requires special control.
Known failure/false conclusionOxidation-state transformations; volatile OsO4 formation risk.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteIridium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: