Platinum
Experimental chemistry • properties • laboratory science
Pt(0)/Pt(II)/Pt(IV); catalysis on clean surfaces and nanoparticles.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 78 |
|---|---|
| Symbol / type | Pt · Transition metal • Solid at room temperature • atomic mass: 195.078 (rounded) |
| Elemental form | Solid | selected oxidation states +2,+4 |
| Chemical identity | Pt(0)/Pt(II)/Pt(IV); catalysis on clean surfaces and nanoparticles. |
| Occurrence and production | Platinum-group ores; extensive recycling. |
| Useful applications | Fuel-cell catalysts, chemical catalysis, lab electrodes and jewelry. |
| Analytical characterization | ICP-MS for catalyst loading; cyclic voltammetry and CO-stripping for electrochemical surface area. |
| Research / quality note | Bulk platinum is not catalytically equivalent to dispersed Pt nanoparticles. |
| Bench properties | Approx. melting 1768.3 °C; density 21.45 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +2 / +4. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 2041.9 K (1768.75 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 4098 K (3824.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Pt-190 | ~650 billion y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pt-192 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pt-194 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pt-195 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pt-196 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pt-198 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2041.9 K(1768.75 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4098 K(3824.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Pt-195m. The BLUE entries refer ONLY to stable nuclides, not to Pt-195m. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
| Nuclear assessment note | NUCLEAR STATUS: Naturally occurring radioisotopes are known or may have extremely long decay half-lives. Never infer “stable” solely from natural abundance. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 37 recorded: 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Metal generally inert; soluble platinum salts cause allergies. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Very low | Repeated clean platinum-metal contact usually produces little skin effect; soluble Pt salts often sensitize. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Moderate | Pure metal dust may irritate; soluble platinum salts can provoke asthma even at low exposure. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | High | Occupational allergy/asthma is strongly associated with soluble platinum salts, not simply intact platinum metal. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Low | Platinum metal is stable in normal air; finely dispersed platinum can act as a potent catalyst. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | No reaction with pure cold water under normal circumstances. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Low | A small accidental amount of clean bulk material is not expected to cause characteristic acute chemical poisoning; particles can still obstruct, irritate or cause choking. | Do not allow ingestion; wash hands and separate food from lab work. CONDITION: Not evidence that the element is edible. |
| Eye exposure | Low | Solid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal. | Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity. |
| Skin absorption | Low | No established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure. | Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness. |
| Fire and explosion | Moderate | Combustible-dust potential increases in finely divided or heated form; clean bulk material is generally less readily ignited. | Check actual powder combustibility; control ignition and dust. CONDITION: Conditional on particle size and process. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Moderate | Loose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk. | Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Moderate | Environmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient. | Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Moderate | Dense or heavy metal pieces can cause impact/crush injury if dropped; machining produces sharp swarf. | Secure mounts and lifting procedures; avoid loose shavings. CONDITION: Physical hazard not a claim of high intrinsic chemical toxicity. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Characterize platinum catalyst loading and oxidation state |
| Expected observation / output | Pt assay, surface area, XPS. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Clean sample mount and correctly calibrated method selected from the target observable; confirm holder compatibility. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Platinum-group ores; extensive recycling. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Pt(0)/Pt(II)/Pt(IV); catalysis on clean surfaces and nanoparticles. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 1768.3 °C and density 21.45 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | ICP-MS for catalyst loading; cyclic voltammetry and CO-stripping for electrochemical surface area. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Bulk platinum is not catalytically equivalent to dispersed Pt nanoparticles. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Nanoparticle catalysts differ from bulk platinum. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Characterize platinum catalyst loading and oxidation state. |
| Measurable evidence | Pt assay, surface area, XPS. Composition versus phase/surface/performance—choose one first. |
| Measurement pathway (candidate) | XRF/OES for bulk assay; XRD/XPS for phase or surface; 4-probe where relevant. |
| Specimen & interpretation boundary | Nanoparticle catalysts differ from bulk platinum. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Gold |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: