Promethium
Experimental chemistry • properties • laboratory science
No stable isotopes; most chemistry resembles trivalent lanthanides.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 61 |
|---|---|
| Symbol / type | Pm · Lanthanide • Solid at room temperature • atomic mass: [145] (indicative nuclide mass number; no standard atomic weight) |
| Elemental form | Solid | selected oxidation states +3 |
| Chemical identity | No stable isotopes; most chemistry resembles trivalent lanthanides. |
| Occurrence and production | Reactor-produced by fission products; specialist separation only. |
| Useful applications | Specialized nuclear sources and research; little bulk industrial use. |
| Analytical characterization | Radiochemical separation and gamma/beta counting as isotope appropriate. |
| Research / quality note | Never extrapolate room-temperature bulk production or routine properties to ordinary labs. |
| Oxidation and chemical forms | Selected: +3. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 1315 K (1041.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 3273 K (2999.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | α-Pm → β-Pm: 1163 K |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Radioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| α-Pm (double hcp) | Solid (elemental baseline; named form stability can differ) | ≈1315 K(1041.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3273 K(2999.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| β-Pm (bcc) | Solid (elemental baseline; named form stability can differ) | ≈1315 K(1041.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3273 K(2999.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | Selected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 1163 K. These are phase boundaries, not safe heating instructions. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Pm-145 | 17.7 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1315 K(1041.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3273 K(2999.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pm-147 | 2.62 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈1315 K(1041.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈3273 K(2999.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | No stable isotopes; representative radioactive form: Pm-147. Isotope, source activity and daughter products must be identified. |
|---|---|
| External radiation — near-term | External: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. |
| External radiation — longer-term | External: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae. |
| Internal exposure — near-term | Internal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. |
| Internal exposure — longer-term | Internal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution. |
| Nuclear assessment note | Radiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 38 recorded: 126, 127, 128, 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 162, 163. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Uncertain | [GREY - unclassified] No normal direct-contact use; any radioactive contamination requires specialist response even without visible irritation. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Uncertain | [GREY - unclassified] No normal skin-contact scenario for promethium metal; radioactive contamination can cause delayed damage. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Uncertain | [GREY - unclassified] Radioactive aerosols may be inhaled without early symptoms and cause internal irradiation. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Uncertain | [GREY - unclassified] Internal organ dose and stochastic cancer risk depend on isotope/activity/intake; only specialist work is appropriate. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Promethium is radioactive and macroscopic air-reaction data are limited; lanthanide-like oxidation is expected. | Interpret together with storage, ignition and process conditions. |
| Water contact | High | Macroscopic elemental water-reaction data are limited; do not infer a validated rate from neighboring lanthanides. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Eye exposure | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Skin absorption | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Bioaccumulation | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Reproductive/developmental effects | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Environmental effects | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Licensed radiochemistry / nuclear facility — Isotope, activity, dose and contamination must be reviewed by radiation-protection staff. |
|---|---|
| Research objective | Interpret promethium isotope assay under licensed programs |
| Expected observation / output | Radionuclide activity and spectral identity. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Authorized isotope-defined source or sealed certified reference, not unspecified “element” material. |
| Sample preparation & apparatus | Licensed shielding/containment, isotope assay, dose-rate and contamination monitoring, RSO authorization. |
| Atmosphere and compatibility | Containment selected by activity, chemical form and isotope; do not infer safe air conditions from element name. |
| Production / refining context | Production and purification are license-restricted; discuss source specification and isotope certification rather than recipes. |
| Reaction, oxidation & corrosion | No stable isotopes; most chemistry resembles trivalent lanthanides. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Activity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended. |
| Electrical / magnetic / optical measurement | Radiochemical separation and gamma/beta counting as isotope appropriate. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Never extrapolate room-temperature bulk production or routine properties to ordinary labs. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | No ordinary laboratory bulk-material study is appropriate. |
| Teaching / research levels | School: non-contact educational spectra. University: published data/approved simulated datasets. Research: licensed isotope-specific procedures. |
| Preservation & data archive | Registered isotope-specific licensed inventory with source integrity, contamination, shielding and expiration review. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T4 • licensed radioactive-material facility; RSO approval required |
|---|---|
| Practical experiment question | Interpret promethium isotope assay under licensed programs. |
| Measurable evidence | Radionuclide activity and spectral identity. Specified radionuclide/activity or isotope ratio (not just element symbol). |
| Measurement pathway (candidate) | Licensed radiometry; isotope-specific assay; matrix chemistry where authorized. |
| Specimen & interpretation boundary | No ordinary laboratory bulk-material study is appropriate. |
| Known failure/false conclusion | Decay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing. |
| Evidence required BEFORE use | IAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Samarium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: