Sodium
Experimental chemistry • properties • laboratory science
Alkali metal; Na(I) dominates; metallic sodium is highly reducing.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 11 |
|---|---|
| Symbol / type | Na · Alkali metal • Solid at room temperature • atomic mass: 22.990 (rounded) |
| Elemental form | Solid | selected oxidation states +1 |
| Chemical identity | Alkali metal; Na(I) dominates; metallic sodium is highly reducing. |
| Occurrence and production | Sodium salts in seawater and evaporites; metal by electrolysis of molten chloride. |
| Useful applications | Sodium-vapor lamps, heat-transfer media and organic synthesis reducing reagents. |
| Analytical characterization | ICP-OES/flame emission for Na impurities; ion chromatography for Na+. |
| Research / quality note | Metallic sodium differs radically from dietary sodium ions. |
| Bench properties | Approx. melting 97.8 °C; density 0.97 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +1. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 370.93 K (97.78 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 1156 K (882.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Low-temperature sodium α | Solid (elemental baseline; named form stability can differ) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Ordinary sodium β | Solid (elemental baseline; named form stability can differ) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| High-pressure sodium phases | Solid (elemental baseline; named form stability can differ) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | Selected evaluated transitions at ~1 atm (NIST TN 2312): α → β = about 45 K. These are phase boundaries, not safe heating instructions. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Na-22 | 2.602 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Na-23 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Na-24 | 14.96 h | Solid (expected elemental chemical form, not isotope-specific observation) | ≈370.93 K(97.78 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈1156 K(882.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Na-22. The BLUE entries refer ONLY to stable nuclides, not to Na-22. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 20 recorded: 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Critical | Moist skin contact causes corrosive burns. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Critical | Repeated skin exposure produces chemical/thermal burns and possible scarring; sodium metal is not dietary sodium. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | High | Metal aerosol or fire products can cause corrosive cough and airway injury. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | High | Long-term effects chiefly follow repeated caustic injury; no routine chronic aerosol exposure should be permitted. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Critical | Sodium rapidly tarnishes in air; moisture and oxygen yield oxides/hydroxide and can initiate fire. | Interpret together with storage, ignition and process conditions. |
| Water contact | Critical | Violently reacts with water, releasing heat, corrosive NaOH and hydrogen; ignition is possible. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Critical | Metal reacts with saliva/body water, generating heat, caustic hydroxide and hydrogen; chemical burns can be severe. | Absolutely prevent ingestion; use inert storage and qualified chemical procedures. CONDITION: Actual severity depends on amount and metal. |
| Eye exposure | Critical | Reactive metal particles plus eye moisture can generate caustic hydroxide and heat, causing serious burns. | Sealed or inert manipulation by trained staff; high-quality face protection and medical response. CONDITION: Strongly form-dependent. |
| Skin absorption | Critical | Water on skin reacts with reactive metal and generates heat and strong alkali, causing burns rather than requiring transdermal absorption. | No bare skin contact; moisture exclusion and emergency planning. CONDITION: Physical chemical reaction, not systemic skin uptake. |
| Fire and explosion | Critical | Reactive metal can ignite after contact with moisture/air; hydrogen generation can trigger fire or explosion. | Inert or approved moisture-excluding storage, trained users and a suitable metal-fire plan. CONDITION: Larger pieces differ from dust; Rb/Cs particularly reactive. |
| Heating and fumes | Critical | Heating highly reactive metal can cause ignition and severe fire/caustic injuries. | Inert atmosphere and purpose-built controlled apparatus only. CONDITION: Temperature/moisture dependent. |
| Chemical incompatibility | Critical | Strong incompatibility with water, moist air, acids and many oxidizers; hydrogen, caustic alkali, heat and fire can result. | Segregate by written compatibility plan; exclude incompatible extinguishing agents and chemicals. CONDITION: Elemental alkali metal, not its salts or ions. |
| Storage and pressure | Critical | Air/moisture exposure, failed seals or unsuitable storage liquids can cause heat, hydrogen and ignition. | Dry compatible inert enclosure and designated segregated storage; inspect seals. CONDITION: Rb/Cs require especially careful moisture exclusion. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | High | Metal spilled into water can generate alkaline solution, heat and hydrogen; acute local aquatic injury and fire risk are possible. | Avoid drains, waterways and wet waste; trained hazardous-waste response. CONDITION: Impact varies with spill mass/dilution. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Moderate | Soft reactive metal may deform; accidental cutting/contact with moist tools adds chemical/fire hazard. | Trained tool use and protected inert handling. CONDITION: Physical handling can trigger chemical reaction. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Trained controlled atmosphere — Avoid unreviewed demonstrations involving elemental reactive metal. |
|---|---|
| Research objective | Contrast sodium metal with sodium-ion compounds using documented specimens |
| Expected observation / output | Phase, concentration or spectra for supplied materials. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Professionally sealed elemental specimen; do not confuse with much safer salt standards. |
| Sample preparation & apparatus | Compatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable. |
| Atmosphere and compatibility | Dry inert atmosphere may be essential for bulk elemental specimens; validate oxygen/water levels; no open-air metal handling. |
| Production / refining context | Occurrence/production context: Sodium salts in seawater and evaporites; metal by electrolysis of molten chloride. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Alkali metal; Na(I) dominates; metallic sodium is highly reducing. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 97.8 °C and density 0.97 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | ICP-OES/flame emission for Na impurities; ion chromatography for Na+. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Metallic sodium differs radically from dietary sodium ions. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Flame color of sodium salts does not prove metallic sodium. |
| Teaching / research levels | School: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol. |
| Preservation & data archive | Only manufacturer/institution-approved sealed dry containment under expert-controlled storage; check packaging integrity. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T3 • controlled atmosphere and trained staff for elemental specimen |
|---|---|
| Practical experiment question | Contrast sodium metal with sodium-ion compounds using documented specimens. |
| Measurable evidence | Phase, concentration or spectra for supplied materials. Total element content; a salt assay does NOT prove elemental-metal purity. |
| Measurement pathway (candidate) | ICP-OES/ICP-MS on certified salt/alloy matrix; sealed optical cell if appropriate. |
| Specimen & interpretation boundary | Flame color of sodium salts does not prove metallic sodium. |
| Known failure/false conclusion | Oxide/moisture growth on elemental surface; seals, contamination and oxidation during transfer. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Magnesium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: