ELEMENT 073 / TRANSITION METAL
73TaATOMIC NUMBER · SYMBOL

Tantalum

Experimental chemistry • properties • laboratory science

Ta(V); corrosion-resistant oxide and high-temperature stability.

Atomic no. 73Transition metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERTaReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number73
Symbol / typeTa · Transition metal • Solid at room temperature • atomic mass: 180.948 (rounded)
Elemental formSolid | selected oxidation states +5
Chemical identityTa(V); corrosion-resistant oxide and high-temperature stability.
Occurrence and productionColtan/tantalite; chemically separated from niobium.
Useful applicationsCapacitors, medical devices and chemical plant equipment.
Analytical characterizationICP-MS for Ta/Nb; capacitance/leakage testing; XPS for oxide.
Research / quality noteCapacitor performance depends on dielectric oxide integrity and powder morphology.
Oxidation and chemical formsSelected: +5. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)3280 K (3006.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)5731 K (5457.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-Ta (bcc)Solid (elemental baseline; named form stability can differ)≈3280 K(3006.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5731 K(5457.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Normal bulk refractory metallic phase. LAB: High conductivity/ductility for pure metal.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~3280 K; generic gas reference ~5731 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-Ta (metastable tetragonal thin-film phase)Solid (elemental baseline; named form stability can differ)≈3280 K(3006.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5731 K(5457.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Common in sputtered films and may be influenced by impurities/processing. LAB: Not an equilibrium bulk high-temperature allotrope; establish film composition and XRD. [AL5]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~3280 K; generic gas reference ~5731 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Ta-180Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3280 K(3006.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5731 K(5457.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3280 K; liquid between ~3280 and ~5731 K; gas above ~5731 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Ta-181Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈3280 K(3006.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5731 K(5457.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3280 K; liquid between ~3280 and ~5731 K; gas above ~5731 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Ta-182114.4 dSolid (expected elemental chemical form, not isotope-specific observation)≈3280 K(3006.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈5731 K(5457.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~3280 K; liquid between ~3280 and ~5731 K; gas above ~5731 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Ta-182. The BLUE entries refer ONLY to stable nuclides, not to Ta-182.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 36 recorded: 155, 156, 157, 158, 159, 160, 161, 162, 163, 164, 165, 166, 167, 168, 169, 170, 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateVery lowBulk generally low acute skin toxicity.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedVery lowRepeated tantalum metal contact is usually low irritation; dust may abrade skin.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateModerateMetal dust may cause nonspecific airway irritation.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedModerateNo well-established chronic toxicity from intact tantalum; particulate process exposures need evaluation.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityModerateTantalum passivates and is highly resistant to ambient air oxidation.Interpret together with storage, ignition and process conditions.
Water contactVery lowHighly resistant to cold water under ordinary conditions.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateIngestion of elemental particles is not a validated safe exposure; toxicity depends on solubility, amount, particle size and transformations in stomach acid.Prevent hand-to-mouth exposure; use elemental-form SDS for any incident. CONDITION: Screening level only.
Eye exposureModerateSolid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal.Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity.
Skin absorptionLowNo established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure.Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness.
Fire and explosionModerateCombustible-dust potential increases in finely divided or heated form; clean bulk material is generally less readily ignited.Check actual powder combustibility; control ignition and dust. CONDITION: Conditional on particle size and process.
Heating and fumesModerateHeating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity.Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes.
Chemical incompatibilityModerateStrong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case.Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix.
Storage and pressureModerateLoose fine powder may disperse, oxidize or create combustible dust; sealed robust packaging lowers immediate risk.Anti-spill, antistatic and particulate containment appropriate to dust and fire properties. CONDITION: Depends strongly on powder size and mass.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsModerateEnvironmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient.Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSchool observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate.
Research objectiveAssess tantalum passive-layer integrity
Expected observation / outputOxide thickness, corrosion current. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound.
Sample preparation & apparatusQualified high-temperature or vacuum instrument; crucible/sample-holder compatibility must be demonstrated.
Atmosphere and compatibilityControl oxygen and temperature for heat tests to prevent misleading oxide formation or holder reaction.
Production / refining contextOccurrence/production context: Coltan/tantalite; chemically separated from niobium. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionTa(V); corrosion-resistant oxide and high-temperature stability. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseUse calibrated thermal profiling only in compatible certified furnace/instrument; record mass/phase before and after.
Electrical / magnetic / optical measurementICP-MS for Ta/Nb; capacitance/leakage testing; XPS for oxide. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationCapacitor performance depends on dielectric oxide integrity and powder morphology. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallTa metal and Ta2O5 dielectric are different phases.
Teaching / research levelsSchool: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study.
Preservation & data archiveUse labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT1/T2 • supervised accessible specimen when form-specific risk assessment permits
Practical experiment questionAssess tantalum passive-layer integrity.
Measurable evidenceOxide thickness, corrosion current. Composition versus phase/surface/performance—choose one first.
Measurement pathway (candidate)XRF/OES for bulk assay; XRD/XPS for phase or surface; 4-probe where relevant.
Specimen & interpretation boundaryTa metal and Ta2O5 dielectric are different phases.
Known failure/false conclusionSample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteTungsten
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: