Technetium
Experimental chemistry • properties • laboratory science
No stable isotope; Tc chemistry includes pertechnetate and multiple oxidation states.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 43 |
|---|---|
| Symbol / type | Tc · Transition metal • Solid at room temperature • atomic mass: [98] (indicative nuclide mass number; no standard atomic weight) |
| Elemental form | Solid | selected oxidation states +4,+7 |
| Chemical identity | No stable isotope; Tc chemistry includes pertechnetate and multiple oxidation states. |
| Occurrence and production | Created by nuclear fission/reactor routes; radiopharmaceutical Tc-99m from generators. |
| Useful applications | Tc-99m medical diagnostic radiopharmaceuticals; radiochemistry research. |
| Analytical characterization | Gamma spectroscopy for Tc-99m; radio-TLC/HPLC for labeling purity. |
| Research / quality note | Any practical interpretation depends on isotope, chemical form and time after production. |
| Oxidation and chemical forms | Selected: +4 / +7. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 2429 K (2155.85 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 4538 K (4264.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Radioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈2429 K(2155.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4538 K(4264.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Tc-97 | 4.21 million y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2429 K(2155.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4538 K(4264.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Tc-98 | 4.2 million y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2429 K(2155.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4538 K(4264.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Tc-99 | ~214,000 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2429 K(2155.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4538 K(4264.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Tc-99m | 6.01 h | Solid (expected elemental chemical form, not isotope-specific observation) | ≈2429 K(2155.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈4538 K(4264.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | No stable isotopes; representative radioactive form: Tc-99m / Tc-99. Isotope, source activity and daughter products must be identified. |
|---|---|
| External radiation — near-term | External: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: Tc-99m emits diagnostic gamma photons; shielding/distance matter for high-activity sources. |
| External radiation — longer-term | External: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae. |
| Internal exposure — near-term | Internal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. Internal distribution of technetium varies greatly with its chemical formulation. |
| Internal exposure — longer-term | Internal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution. |
| Nuclear assessment note | Radiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 34 recorded: 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Uncertain | [GREY - unclassified] Visible skin injury is not an immediate indicator of radioactive contact; contamination and local dose need assessment. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Uncertain | [GREY - unclassified] Skin may show no immediate injury after contamination; delayed dose-related injury is possible. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Uncertain | [GREY - unclassified] Inhaled radioactive particles may cause no immediate symptoms but produce internal dose. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Uncertain | [GREY - unclassified] Cancer and organ risks depend on isotope, chemical form, intake and dose; no routine unlicensed exposure. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Moderate | Technetium chemistry depends on oxidation state and radioactive isotope; bulk air-reactivity data are limited. | Interpret together with storage, ignition and process conditions. |
| Water contact | Low | No generic room-temperature metal-water reaction can be safely asserted; oxidizing aqueous systems may form mobile pertechnetate. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Eye exposure | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Skin absorption | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Bioaccumulation | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Reproductive/developmental effects | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Environmental effects | Uncertain | No stable isotopes; internal or external exposure depends on nuclide, activity, chemical form and containment. | Licensed radioisotope procedures and verified radionuclide-specific assessment. CONDITION: Technetium/promethium: no ordinary stable elemental sample. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Licensed radiochemistry / nuclear facility — Isotope, activity, dose and contamination must be reviewed by radiation-protection staff. |
|---|---|
| Research objective | Review technetium radionuclide identification using licensed data |
| Expected observation / output | Gamma spectrum and activity record. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Authorized isotope-defined source or sealed certified reference, not unspecified “element” material. |
| Sample preparation & apparatus | Licensed shielding/containment, isotope assay, dose-rate and contamination monitoring, RSO authorization. |
| Atmosphere and compatibility | Containment selected by activity, chemical form and isotope; do not infer safe air conditions from element name. |
| Production / refining context | Production and purification are license-restricted; discuss source specification and isotope certification rather than recipes. |
| Reaction, oxidation & corrosion | No stable isotope; Tc chemistry includes pertechnetate and multiple oxidation states. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Activity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended. |
| Electrical / magnetic / optical measurement | Gamma spectroscopy for Tc-99m; radio-TLC/HPLC for labeling purity. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Any practical interpretation depends on isotope, chemical form and time after production. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Specialist radiochemistry only; no general-lab elemental sample. |
| Teaching / research levels | School: non-contact educational spectra. University: published data/approved simulated datasets. Research: licensed isotope-specific procedures. |
| Preservation & data archive | Registered isotope-specific licensed inventory with source integrity, contamination, shielding and expiration review. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T4 • licensed radioactive-material facility; RSO approval required |
|---|---|
| Practical experiment question | Review technetium radionuclide identification using licensed data. |
| Measurable evidence | Gamma spectrum and activity record. Specified radionuclide/activity or isotope ratio (not just element symbol). |
| Measurement pathway (candidate) | Licensed radiometry; isotope-specific assay; matrix chemistry where authorized. |
| Specimen & interpretation boundary | Specialist radiochemistry only; no general-lab elemental sample. |
| Known failure/false conclusion | Decay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing. |
| Evidence required BEFORE use | IAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Ruthenium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: