Arsenic
Experimental chemistry • properties • laboratory science
Metalloid with As(III)/As(V) species; arsenides are semiconductor materials.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 33 |
|---|---|
| Symbol / type | As · Metalloid • Solid at room temperature • atomic mass: 74.922 (rounded) |
| Elemental form | Solid | selected oxidation states -3,+3,+5 |
| Chemical identity | Metalloid with As(III)/As(V) species; arsenides are semiconductor materials. |
| Occurrence and production | Associated with sulfide ores; recovered chiefly as industrial byproduct. |
| Useful applications | GaAs semiconductor manufacture; controlled specialty glass chemistry. |
| Analytical characterization | Speciation by HPLC-ICP-MS; XRD for GaAs phases. |
| Research / quality note | Elemental arsenic, arsenite, arsenate and arsine gas are distinct materials. |
| Oxidation and chemical forms | Selected: -3 / +3 / +5. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | No equilibrium melting at ~1 atm; solid sublimes near 889 K (616 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | No normal boiling boundary at ~1 atm; sublimation at ~889 K |
| Sublimation (solid → gas) near 1 atm | 889 K (615.85 °C) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Ordinary-pressure arsenic sublimes near 889 K (~616 °C); melting requires elevated pressure (RSC fact box). |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Gray arsenic | Solid (elemental baseline; named form stability can differ) | No melt at 1 atm; triple point ~1090 K at 37 atm (NOT the normal melting point) | ~887 K(solid arsenic → vapor, ~1 atm; NIST TN2312) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Yellow arsenic (As4) | Solid (elemental baseline; named form stability can differ) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Black arsenic | Solid (elemental baseline; named form stability can differ) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: use phase-specific powder/single-crystal XRD, Raman or other appropriate spectroscopy, with documented temperature, pressure, composition, impurities, substrate and thermal history. A color or appearance alone is insufficient. |
| Evidence & scope | Evidence & scope: [AL11]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| As-75 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| As-76 | 1.09 d | Solid (expected elemental chemical form, not isotope-specific observation) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: As-76. The BLUE entries refer ONLY to stable nuclides, not to As-76. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 33 recorded: 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Moderate | A brief touch of an intact elemental piece may have no immediate symptom, but dust and transfer to mouth are unacceptable. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Moderate | Dust/compound contamination of skin can cause irritation and transfer into the mouth; arsenic compounds vary greatly. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Critical | Arsenic-bearing dust can irritate; toxic inorganic arsenic compounds or generated arsine may cause systemic poisoning. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Repeated inorganic arsenic exposure is linked to skin changes, neuropathy and cancer; risk is compound- and route-specific. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Elemental arsenic may oxidize slowly, especially when heated, producing highly toxic arsenic oxides/fumes. | Interpret together with storage, ignition and process conditions. |
| Water contact | Low | No vigorous reaction of solid arsenic with pure water at ordinary conditions; aqueous behavior is compound-specific. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | High | Arsenic-containing particles present poisoning concerns; elemental arsenic and soluble inorganic arsenic compounds do NOT have equal absorption. | No ingestion exposure; control dust; verify actual arsenic species before risk estimation. CONDITION: Species-dependent; do not copy arsenic-trioxide data to metal. |
| Eye exposure | Moderate | Dust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms. | Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye. |
| Skin absorption | Low | Clean bulk metal does not readily penetrate intact skin; contamination on hands can be swallowed, and soluble compounds behave differently. | Prevent contamination and hand-to-mouth transfer; wash with suitable method. CONDITION: Different from skin contact with salts. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Critical | Heating arsenic in air can generate highly toxic arsenic oxides/vapors; systemic and respiratory harm possible. | Closed engineering controls; do not heat casually. CONDITION: Elemental As versus oxide conversion. |
| Chemical incompatibility | Moderate | Oxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products. | Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | High | Repeated inorganic arsenic exposure can cause chronic systemic illness; species and elimination differ, so not all forms bioaccumulate alike. | Control continuous intake and identify arsenic species. CONDITION: Avoid claiming elemental As equals soluble arsenic. |
| Reproductive/developmental effects | Moderate | Inorganic arsenic exposures have documented reproductive/developmental concerns, but evidence from soluble compounds cannot be directly transferred to intact metalloid pieces. | Prevent particulate intake and assess specific arsenic form. CONDITION: Species-dependent. |
| Environmental effects | High | Arsenic contamination can persist and become mobile depending on oxidation state and water chemistry, affecting soil/water safety. | Prevent runoff, dust dispersion and uncontrolled disposal; test species where needed. CONDITION: Elemental particles and dissolved arsenic differ. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Moderate | Crystalline or brittle pieces can fracture into sharp fragments; processing produces particulate. | Cut/cleave behind guards; avoid dust and chips. CONDITION: Form-dependent; diamond is hard, graphite soft. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Professional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment. |
|---|---|
| Research objective | Determine arsenic concentration safely in certified solid references |
| Expected observation / output | ICP-MS/elemental assay. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Enclosed instrument or preprepared certified reference; exposure and waste control are prerequisites. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Context: Associated with sulfide ores; recovered chiefly as industrial byproduct. For teaching, use certified prepared materials; industrial extraction is not a bench recipe. |
| Reaction, oxidation & corrosion | Metalloid with As(III)/As(V) species; arsenides are semiconductor materials. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Select temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes. |
| Electrical / magnetic / optical measurement | Speciation by HPLC-ICP-MS; XRD for GaAs phases. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Elemental arsenic, arsenite, arsenate and arsine gas are distinct materials. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Elemental arsenic is not suitable for classroom manipulation. |
| Teaching / research levels | School: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol. |
| Preservation & data archive | Certified containment and segregated inventory with contamination monitoring and disposal protocol. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T3 • specialized controlled professional facility; no open handling |
|---|---|
| Practical experiment question | Determine arsenic concentration safely in certified solid references. |
| Measurable evidence | ICP-MS/elemental assay. Trace/major element concentration in specified matrix. |
| Measurement pathway (candidate) | Certified solid or solution CRM by ICP-MS/XRF as matrix permits. |
| Specimen & interpretation boundary | Elemental arsenic is not suitable for classroom manipulation. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Selenium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: