Selenium
Experimental chemistry • properties • laboratory science
Se(0)/Se(IV)/Se(VI) chemistry; photoconductivity and chalcogenide semiconductors.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 34 |
|---|---|
| Symbol / type | Se · Nonmetal • Solid at room temperature • atomic mass: 78.960 (rounded) |
| Elemental form | Solid | selected oxidation states -2,+4,+6 |
| Chemical identity | Se(0)/Se(IV)/Se(VI) chemistry; photoconductivity and chalcogenide semiconductors. |
| Occurrence and production | Byproduct of copper electrolytic refining. |
| Useful applications | Glass decolorizing, photovoltaics, xerography and trace nutrition (compounds). |
| Analytical characterization | ICP-MS for total Se; HPLC-ICP-MS for species; UV-vis for semiconductors. |
| Research / quality note | Essential trace selenium intake does not make elemental Se harmless. |
| Bench properties | Approx. melting 221 °C; density 4.81 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: -2 / +4 / +6. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 494.2 K (221.05 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 958 K (684.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | Red Se → gray Se: 407.2 K; depends on form |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Gray/trigonal selenium | Solid | 494.2 ± 0.1 K(gray trigonal selenium → liquid; NIST TN 2312) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Red crystalline selenium (α, β, γ monoclinic Se8-ring forms) | Solid | Reported red → black: 327.2 ± 0.5 K; red → gray: 407.2 K (different pathways; NOT a universal melt) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Red amorphous selenium | Solid | Red crystalline → black 327.2 ± 0.5 K (RELATED form only; not validated for amorphous red Se) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Black vitreous/glassy selenium | Solid | Black vitreous → amorphous: ~318 ± 2 K; black → gray ~395 ± 5 K (reported); glass → solid 314 K (distinct processes) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Se6 and Se7 cyclic molecular variants | Solid (elemental baseline; named form stability can differ) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: use phase-specific powder/single-crystal XRD, Raman or other appropriate spectroscopy, with documented temperature, pressure, composition, impurities, substrate and thermal history. A color or appearance alone is insufficient. |
| Evidence & scope | Evidence & scope: [AL3, AL12]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Se-74 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-75 | 119.8 d | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-76 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-77 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-78 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-80 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Se-82 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈494.2 K(221.05 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈958 K(684.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Se-75. The BLUE entries refer ONLY to stable nuclides, not to Se-75. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 30 recorded: 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Moderate | Element may irritate; prolonged skin contact undesirable. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Moderate | Repeated selenium/selenide contact may produce dermatitis; sustained systemic exposure can affect hair/nails. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | High | Dust or fumes may irritate eyes and respiratory tract; high doses can cause systemic effects. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Long-term excess selenium uptake can cause selenosis (hair/nail changes, neurologic symptoms); chemical form matters. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Selenium is relatively stable in ordinary air; heating/burning produces irritating selenium oxides. | Interpret together with storage, ignition and process conditions. |
| Water contact | Low | Elemental selenium has poor water solubility and no normal vigorous reaction. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Moderate | Elemental particles may cause gastrointestinal or systemic effects after sufficient intake; soluble compounds generally have distinct absorption. | Prevent accidental swallowing; review SDS for particle size and chemistry. CONDITION: Do not infer effects from soluble salts. |
| Eye exposure | Moderate | Dust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms. | Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye. |
| Skin absorption | Low | No established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure. | Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | High | Heating can generate irritating or toxic oxide/metal fumes; hazards are greater than from cold intact metal. | Local exhaust and process-specific exposure assessment. CONDITION: Metal and formed oxide should be assessed separately. |
| Chemical incompatibility | Moderate | Oxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products. | Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | Moderate | These elements may be present in normal physiology or retained after overexposure; harmful loading depends on dose and chemical form. | Avoid chronic excess exposure; assess blood/urine/tissue measurements only when indicated. CONDITION: Essential nutrient status does not mean safe unlimited intake. |
| Reproductive/developmental effects | Uncertain | Reproductive effects reported for some metal compounds/high exposures; evidence is insufficient for a general rating of ordinary elemental solid. | Check substance-form reproductive data and institutional occupational health guidance. CONDITION: Uncertain form-specific risk. |
| Environmental effects | High | Releases of metal particles or soluble products can threaten aquatic or terrestrial organisms; toxicity depends on speciation and dose. | Contain wastewater and particulate residues; follow waste regulations. CONDITION: Never assume elemental metal dissolves at salt-like rates. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Evaluate selenium-containing functional materials by oxidation state |
| Expected observation / output | XPS and Raman. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Document exact allotrope, crystalline/amorphous phase, dopant level and surface finish. |
| Sample preparation & apparatus | Clean tools, substrate/sample fixture, four-probe/Raman/XRD as appropriate; manage surface contamination. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Byproduct of copper electrolytic refining. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Se(0)/Se(IV)/Se(VI) chemistry; photoconductivity and chalcogenide semiconductors. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 221 °C and density 4.81 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | ICP-MS for total Se; HPLC-ICP-MS for species; UV-vis for semiconductors. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Essential trace selenium intake does not make elemental Se harmless. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Elemental Se and selenium compounds are not interchangeable. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Evaluate selenium-containing functional materials by oxidation state. |
| Measurable evidence | XPS and Raman. Crystal/allotrope or semiconductor composition. |
| Measurement pathway (candidate) | Raman/XRD and appropriate compositional assay. |
| Specimen & interpretation boundary | Elemental Se and selenium compounds are not interchangeable. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Bromine |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: