Astatine
Experimental chemistry • properties • laboratory science
Very rare halogen, radioactive; only atom-at-a-time solution chemistry.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 85 |
|---|---|
| Symbol / type | At · Halogen • No measured bulk sample at room temperature • atomic mass: [210] (indicative nuclide mass number; no standard atomic weight) |
| Elemental form | No measured bulk sample | selected oxidation states -1,+1,+5 |
| Chemical identity | Very rare halogen, radioactive; only atom-at-a-time solution chemistry. |
| Occurrence and production | Cyclotron production of At-211 in specialist facilities. |
| Useful applications | Targeted alpha therapy research (At-211 labelled compounds). |
| Analytical characterization | Radiochemical separation, radio-HPLC and alpha/gamma assays as appropriate. |
| Research / quality note | No photographed ordinary macroscopic metal piece; bulk properties unavailable. |
| Oxidation and chemical forms | Not a routinely measured bulk property; oxidation-state reports need original experimental evidence. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | ≈573 K (299.85 °C) (published secondary estimate, not measured) |
| Elemental-bulk boiling / gas formation (near 1 atm) | ≈623 K (349.85 °C) (published secondary estimate, not measured) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | RSC tabulated estimates only; no macroscopic astatine specimen has been measured. Do not label as experimental. Short half-life prevents bulk sample. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈573 K(299.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) | ≈623 K(349.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| At-210 | 8.1 h | Solid (expected elemental chemical form, not isotope-specific observation) | ≈573 K(299.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) | ≈623 K(349.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| At-211 | 7.21 h | Solid (expected elemental chemical form, not isotope-specific observation) | ≈573 K(299.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) | ≈623 K(349.85 °C) (published elemental-bulk ESTIMATE, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | No stable isotopes; representative radioactive form: At-211. Isotope, source activity and daughter products must be identified. |
|---|---|
| External radiation — near-term | External: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: At-211 is primarily an alpha-emitting medical-research radionuclide; no ordinary metallic sample exists. |
| External radiation — longer-term | External: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae. |
| Internal exposure — near-term | Internal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. Internal distribution depends on astatine chemical form and the biological targeting agent. |
| Internal exposure — longer-term | Internal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution. |
| Nuclear assessment note | Radiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 31 recorded: 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 223. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Uncertain | [GREY - unclassified] No ordinary visible sample is available; no immediate symptom can be predicted from isotope identity alone. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Uncertain | [GREY - unclassified] No ordinary macroscopic contact; short-lived radioactivity and form-specific contamination dominate. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Uncertain | [GREY - unclassified] No routine inhalation scenario; volatile/airborne radioactive atoms could cause internal exposure. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Uncertain | [GREY - unclassified] Effect depends on isotope and intake; routine chronic human data do not exist. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Uncertain | [GREY - unclassified] Astatine has no ordinary macroscopic metal specimen; bulk reactions with ambient air have not been measured. | Interpret together with storage, ignition and process conditions. |
| Water contact | Uncertain | [GREY - unclassified] Bulk astatine-water behavior is not experimentally established; aqueous astatine chemistry is studied at tracer levels. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Eye exposure | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Skin absorption | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Fire and explosion | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Heating and fumes | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Chemical incompatibility | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Storage and pressure | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Bioaccumulation | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Reproductive/developmental effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Environmental effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Cryogenic effects | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
| Mechanical and pressure hazards | Uncertain | Data not established for an ordinary macroscopic elemental sample; do not extrapolate from salts or predictions. | Restricted nuclear or specialist facilities only; require authenticated isotope/form/activity and site-specific controls. CONDITION: No bulk elemental handling scenario. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Specialist ultratrace facility — Ordinary bulk experiments impossible or inappropriate; analysis of records only. |
|---|---|
| Research objective | Study astatine through published radio-tracer measurements |
| Expected observation / output | Decay product and chemistry record. Predetermine units, calibration basis and appropriate control. |
| Available physical form | No routine visible elemental specimen; published tracer/isotope measurement or certified record. |
| Sample preparation & apparatus | Specialist isotope-separation instrument and radiometric detection; no transferable open-bench protocol. |
| Atmosphere and compatibility | Containment selected by activity, chemical form and isotope; do not infer safe air conditions from element name. |
| Production / refining context | Specialist radioactive tracer preparation. Report chemical separation factor only when supported by a licensed protocol. |
| Reaction, oxidation & corrosion | Very rare halogen, radioactive; only atom-at-a-time solution chemistry. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Activity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended. |
| Electrical / magnetic / optical measurement | Radiochemical separation, radio-HPLC and alpha/gamma assays as appropriate Report tracer/atom-scale inference only; never imply bulk-sample measurement. |
| Quantification & verification | No photographed ordinary macroscopic metal piece; bulk properties unavailable. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | No visible bulk astatine specimen is generally accessible. |
| Teaching / research levels | School: spectra/photos/verified published data only. University: supervised nuclear-data analysis. Research: authorized atom-scale experiment. |
| Preservation & data archive | Research documentation and authorized nuclear inventory only; no routine storage of bulk elemental specimen. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T5 • no routine macroscopic elemental specimen; specialist isotope facility only |
|---|---|
| Practical experiment question | Study astatine through published radio-tracer measurements. |
| Measurable evidence | Decay product and chemistry record. Nuclide-specific activity/decay evidence. |
| Measurement pathway (candidate) | Published specialized tracer or decay records. |
| Specimen & interpretation boundary | No visible bulk astatine specimen is generally accessible. |
| Known failure/false conclusion | Decay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing. |
| Evidence required BEFORE use | IAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Radon |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: