ELEMENT 084 / POST-TRANSITION METAL
84PoATOMIC NUMBER · SYMBOL

Polonium

Experimental chemistry • properties • laboratory science

Radioactive alpha emitter; no macroscopic general-lab role.

Atomic no. 84Post-transition metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERPoReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number84
Symbol / typePo · p-block/post-transition element • Solid at room temperature • atomic mass: [209] (indicative nuclide mass number; no standard atomic weight)
Elemental formSolid | selected oxidation states +2,+4
Chemical identityRadioactive alpha emitter; no macroscopic general-lab role.
Occurrence and productionTrace natural decay products; specialist production in reactors.
Useful applicationsSpecialist alpha-source and nuclear research.
Analytical characterizationAlpha spectrometry and radiochemical separation.
Research / quality noteRisk is isotope/activity specific; no routine elemental specimen profile is defensible.
Oxidation and chemical formsSelected: +2 / +4. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)527 K (253.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)1235 K (961.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitionsα-Po → β-Po: 327 K
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationRadioactive / scarce element: literature evaluation is not evidence of a measured isotope-specific melting point. Check sample identity, uncertainty and reference. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-Po (simple cubic)Solid (elemental baseline; named form stability can differ)≈527 K(253.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1235 K(961.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Rare elemental simple-cubic crystal at lower temperature. LAB: Structure established with special isotope samples; substantial radiotoxicity.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~527 K; generic gas reference ~1235 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-Po (rhombohedral)Solid (elemental baseline; named form stability can differ)≈527 K(253.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1235 K(961.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Higher-temperature solid phase; α→β near 327 K. LAB: No routine laboratory experiment is implied by inclusion. [AL3,AL19]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~527 K; generic gas reference ~1235 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
Named forms noted in chapterRadioactive alpha emitter; no macroscopic general-lab role.
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 327 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL3, AL19]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Po-209124 ySolid (expected elemental chemical form, not isotope-specific observation)≈527 K(253.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1235 K(961.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
alpha
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~527 K; liquid between ~527 and ~1235 K; gas above ~1235 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Po-210138.4 dSolid (expected elemental chemical form, not isotope-specific observation)≈527 K(253.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1235 K(961.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
alpha
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~527 K; liquid between ~527 and ~1235 K; gas above ~1235 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisNo stable isotopes; representative radioactive form: Po-210. Isotope, source activity and daughter products must be identified.
External radiation — near-termExternal: exposure can be negligible for alpha behind intact barriers, or substantial for beta/gamma/neutrons at sufficient activity. Acute skin injury or systemic radiation illness requires high absorbed dose. Specific example: Po-210 emits alpha particles, which do not penetrate intact skin; a leaking source is still a contamination emergency.
External radiation — longer-termExternal: cumulative dose can increase later cancer/cataract/skin risks depending on organ dose, rate, and time; high-dose injury may leave chronic sequelae.
Internal exposure — near-termInternal: inhaled/ingested particles, gases or intake through wounds may deliver organ dose, even without immediate symptoms. At high intake, local tissue or systemic injury is possible. Inhaled or ingested Po-210 can deliver extremely damaging internal alpha dose, including potentially fatal organ injury at sufficiently high intake.
Internal exposure — longer-termInternal: retained radionuclides may deliver committed dose over time; cancer risk or chronic organ effects depend on radiation type, retention and tissue distribution.
Nuclear assessment noteRadiation distance: No universal safe distance; assess isotope, activity, emitted energies, daughter products, shielding and actual dose rates.

Isotope mass-number inventory (reference registry; not complete ENSDF): 33 recorded: 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateUncertain[GREY - unclassified] Skin may initially look normal after contact; transferable alpha-emitting contamination is exceptionally hazardous.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedUncertain[GREY - unclassified] No immediate skin symptom is guaranteed; transferable radioactive contamination is the main concern.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateCriticalAirborne polonium particles may give no immediate warning; inhalation can cause a major internal alpha dose.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalDepending on intake, severe organ injury, radiation illness or later cancer may occur; do not infer risk from distance alone.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityUncertain[GREY - unclassified] Polonium is intensely radioactive; any real metal exposure also entails isotope-specific radiation/contamination risks; surface oxidation possible.Interpret together with storage, ignition and process conditions.
Water contactUncertain[GREY - unclassified] Reliable macroscopic elemental water-reaction rates are not appropriate to assume; radionuclide form controls mobility.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionUncertainPolonium-210 ingestion can be an extremely serious internal alpha exposure; dose depends on isotope and activity.Specialist licensed sources only; no school or general-lab samples. CONDITION: Radiological, not merely chemical.
Eye exposureModerateSolid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal.Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity.
Skin absorptionLowNo established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure.Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesModerateHeating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity.Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes.
Chemical incompatibilityModerateStrong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case.Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix.
Storage and pressureUncertainSealed-source certification, activity, contamination control, gas ingrowth and decay products can govern storage; no generic safe glass arrangement.Radiation safety officer, source registry, security and engineered containment. CONDITION: Isotope/activity and sealed status required.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainReproductive/fetal exposure from radionuclides is dose-, isotope- and pregnancy-stage-dependent; no defensible generic element grade.Radiation safety expert and pregnancy-specific workplace assessment when relevant. CONDITION: Not equivalent to chemical developmental toxicity.
Environmental effectsUncertainEnvironmental persistence, internal dose and hazard depend on isotope activity, chemical form, decay chain and transport pathways.Follow radiation permits, monitored effluent and radioactive-waste management. CONDITION: No safe-disposal inference from half-life.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierLicensed radiochemistry / nuclear facility — Isotope, activity, dose and contamination must be reviewed by radiation-protection staff.
Research objectiveInterpret polonium alpha sources from licensed spectroscopy data
Expected observation / outputAlpha energy and activity documentation. Predetermine units, calibration basis and appropriate control.
Available physical formAuthorized isotope-defined source or sealed certified reference, not unspecified “element” material.
Sample preparation & apparatusLicensed shielding/containment, isotope assay, dose-rate and contamination monitoring, RSO authorization.
Atmosphere and compatibilityContainment selected by activity, chemical form and isotope; do not infer safe air conditions from element name.
Production / refining contextProduction and purification are license-restricted; discuss source specification and isotope certification rather than recipes.
Reaction, oxidation & corrosionRadioactive alpha emitter; no macroscopic general-lab role. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseActivity/time, chemical form and containment drive choice; no generic heating, vacuum or pressure experiment recommended.
Electrical / magnetic / optical measurementAlpha spectrometry and radiochemical separation. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationRisk is isotope/activity specific; no routine elemental specimen profile is defensible. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallNo teaching-lab handling; high contamination concern.
Teaching / research levelsSchool: non-contact educational spectra. University: published data/approved simulated datasets. Research: licensed isotope-specific procedures.
Preservation & data archiveRegistered isotope-specific licensed inventory with source integrity, contamination, shielding and expiration review.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT4 • licensed radioactive-material facility; RSO approval required
Practical experiment questionInterpret polonium alpha sources from licensed spectroscopy data.
Measurable evidenceAlpha energy and activity documentation. Specified radionuclide/activity or isotope ratio (not just element symbol).
Measurement pathway (candidate)Licensed radiometry; isotope-specific assay; matrix chemistry where authorized.
Specimen & interpretation boundaryNo teaching-lab handling; high contamination concern.
Known failure/false conclusionDecay timing, progeny, chemical form, cross-contamination, spectral overlap and licensing.
Evidence required BEFORE useIAEA nuclide reference + facility RSO records + isotope method/CRM [R12–R13].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteAstatine
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: