ELEMENT 035 / HALOGEN
35BrATOMIC NUMBER · SYMBOL

Bromine

Experimental chemistry • properties • laboratory science

Br2 is volatile liquid; bromide and brominating agents differ.

Atomic no. 35HalogenLiquid at room conditions
Explore profile
IMAGE PLACEHOLDERBrReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number35
Symbol / typeBr · Halogen • Liquid at room temperature • atomic mass: 79.904 (rounded)
Elemental formLiquid | selected oxidation states -1,+1,+5
Chemical identityBr2 is volatile liquid; bromide and brominating agents differ.
Occurrence and productionBromide-rich brines extracted/oxidized to Br2.
Useful applicationsFlame retardant intermediates, pharmaceuticals and specialty chemical synthesis.
Analytical characterizationIon chromatography for bromide; GC for organobromines; Raman for Br2 complexes.
Research / quality noteControl light, containment and speciation; elemental Br2 is not bromide salt.
Bench propertiesApprox. melting -7.2 °C; density 3.12 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: -1 / +1 / +5. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmLiquid
Elemental-bulk melting / freezing (near 1 atm)265.9 K (-7.25 °C)
Elemental-bulk boiling / gas formation (near 1 atm)332 K (58.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formLiquid265.90 K(−7.25 °C; Br₂)≈332 K(58.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Bromine is molecular Br2, with a molecular crystal when frozen; no second ordinary bulk molecular allotrope is established. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this form at ~1 atm: solid below ~265.9 K; liquid between ~265.9 and ~332 K; gas above ~332 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
Pressure and thermal history required; phase at 20 °C does not imply the named polymorph is stable
Evidence level
Curated form-specific transition (NIST TN 2312 / literature; check stated conditions)
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Br-79Natural; possible extremely long-lived radioactivityLiquid (expected elemental chemical form, not isotope-specific observation)≈265.9 K(-7.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈332 K(58.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Verify ENSDF
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~265.9 K; liquid between ~265.9 and ~332 K; gas above ~332 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Br-81Half-life/status not independently verified hereLiquid (expected elemental chemical form, not isotope-specific observation)≈265.9 K(-7.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈332 K(58.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~265.9 K; liquid between ~265.9 and ~332 K; gas above ~332 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Br-8235.3 hLiquid (expected elemental chemical form, not isotope-specific observation)≈265.9 K(-7.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈332 K(58.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~265.9 K; liquid between ~265.9 and ~332 K; gas above ~332 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Br-82. The BLUE entries refer ONLY to stable nuclides, not to Br-82.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 31 recorded: 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateCriticalLiquid causes severe chemical burns.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedCriticalRepeated bromine liquid/vapor exposure can cause dermatitis and lasting burn scars.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateCriticalBromine vapor irritates intensely; high exposure causes chemical pneumonitis or delayed pulmonary edema.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalChronic irritation or persistent lung dysfunction may follow repeated exposure or severe accidents.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityCriticalBromine releases corrosive vapor in air; reacts with certain materials and is a strong oxidant.Interpret together with storage, ignition and process conditions.
Water contactHighPartly dissolves and hydrolyzes in water, forming bromide and hypobromous acid species; hazardous solution remains.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionCriticalCorrosive elemental halogen causes severe mouth, throat and gastrointestinal tissue injury; associated inhalation may dominate for gases.Use a closed compatible system; emergency response and immediate medical evaluation for exposure. CONDITION: F2/Cl2 gases; Br2 volatile liquid.
Eye exposureCriticalElemental halogen vapor or liquid can cause severe eye irritation/corrosive damage, potentially permanent vision injury.Closed equipment plus splash/face protection and accessible eyewash; emergency medical care. CONDITION: Gas or liquid form makes exposure rapid.
Skin absorptionCriticalLiquid bromine causes deep chemical burns; dermal penetration and systemic uptake can accompany injury.Closed compatible vessels; professional PPE and emergency treatment capability. CONDITION: Elemental Br2.
Fire and explosionHighElemental halogen is not normally flammable but is oxidizing/reactive and can intensify or cause fire with incompatible materials.Strict segregation from fuels, reducers and reactive metals. CONDITION: Not an ordinary combustible fuel.
Heating and fumesCriticalHeating increases volatilization of corrosive halogen or vapor and raises risks of severe eye/airway injury.Closed temperature-rated corrosion-resistant system. CONDITION: F2/Cl2 gases, Br2 liquid, I2 solid.
Chemical incompatibilityCriticalStrong oxidizing halogen reacts with metals, reducers, organics and many other incompatible materials; corrosive gases may form.Chemical compatibility matrix for every contacted seal, reagent and exhaust path. CONDITION: Reagent-specific severity.
Storage and pressureCriticalBromine leaks release corrosive toxic vapor; incompatible seals can fail.Closed compatible chemically resistant containment inside secondary enclosure. CONDITION: Temperature control and pressure matter.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsCriticalHalogen gas/liquid releases can injure plants and aquatic life or form harmful reactive products in water/air.Prevent vented releases; compatible scrubbing and waste capture by trained staff. CONDITION: Chemical release, not radiological.
Cryogenic effectsModerateRefrigerated or molten/solid form may cause thermal injury; corrosive halogen exposure remains the main hazard.Control cold/hot handling and corrosion-resistant containment. CONDITION: Not necessarily below conventional cryogenic temperature.
Mechanical and pressure hazardsModeratePressurized/released halogen can propel or splash material; chemical corrosivity is handled separately.Pressure containment, shields and compatible fittings. CONDITION: Physical plus chemical hazard.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierProfessional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment.
Research objectiveIdentify bromine-related chemistry without exposing people to Br2
Expected observation / outputCertified bromide quantification. Predetermine units, calibration basis and appropriate control.
Available physical formCertified sealed specimen or approved reference material; vapor containment is critical.
Sample preparation & apparatusEnclosed instrument or preprepared certified reference; exposure and waste control are prerequisites.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextContext: Bromide-rich brines extracted/oxidized to Br2. For teaching, use certified prepared materials; industrial extraction is not a bench recipe.
Reaction, oxidation & corrosionBr2 is volatile liquid; bromide and brominating agents differ. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseMaintain documented temperature and vapor containment; melting/evaporation tests require specialist review.
Electrical / magnetic / optical measurementIon chromatography for bromide; GC for organobromines; Raman for Br2 complexes. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationControl light, containment and speciation; elemental Br2 is not bromide salt. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallBr2 liquid/vapor needs specialist engineering controls.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveApproved tight container with secondary containment, vapor control and material compatibility verification.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • specialized controlled professional facility; no open handling
Practical experiment questionIdentify bromine-related chemistry without exposing people to Br2.
Measurable evidenceCertified bromide quantification. Halide concentration, NOT free halogen element.
Measurement pathway (candidate)Certified halide standard; IC or appropriate species-selective method.
Specimen & interpretation boundaryBr2 liquid/vapor needs specialist engineering controls.
Known failure/false conclusionHalide species versus element, volatilization, container interaction and reagent blanks.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteKrypton
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: