Carbon
Experimental chemistry • properties • laboratory science
Diamond, graphite, graphene, amorphous carbon and nanotubes differ drastically in bonding and properties.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 6 |
|---|---|
| Symbol / type | C · Nonmetal • Solid at room temperature • atomic mass: 12.011 (rounded) |
| Elemental form | Solid | selected oxidation states -4,+2,+4 |
| Chemical identity | Diamond, graphite, graphene, amorphous carbon and nanotubes differ drastically in bonding and properties. |
| Occurrence and production | Coal, hydrocarbons, biomass; high-purity graphite and synthetic diamond produced industrially. |
| Useful applications | Steelmaking, electrodes, filters, structural composites and semiconductor diamond. |
| Analytical characterization | Raman spectroscopy for allotropes/defects; combustion analysis for carbon content. |
| Research / quality note | Never infer properties from 'carbon' alone: allotrope, morphology and defects control performance. |
| Oxidation and chemical forms | Selected: -4 / +2 / +4. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | Not applicable near 1 atm — graphite sublimes; high-pressure melting is separate |
| Elemental-bulk boiling / gas formation (near 1 atm) | ? |
| Sublimation (solid → gas) near 1 atm | ? |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Carbon sublimes near ambient pressure; no ordinary 1-atm melting point. High-pressure melting is form-dependent. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Graphite (hexagonal and rhombohedral stacking) | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Diamond (cubic) | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Hexagonal diamond / lonsdaleite-type structures | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Graphene | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Fullerenes (C60, C70, larger families) | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Carbon nanotubes | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Carbyne / linear carbon chains | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Amorphous/glassy/disordered carbon and carbon nanofoams | Solid / structural form; stability and sample dependent | Not defined at ~1 atm for this structural form; graphite has no ordinary-pressure melting point | Graphite stable to at least ~4000 K (NIST standard-state discussion); NOT a sublimation point |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Named forms noted in chapter | Diamond, graphite, graphene, amorphous carbon and nanotubes differ drastically in bonding and properties. |
|---|---|
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: use phase-specific powder/single-crystal XRD, Raman or other appropriate spectroscopy, with documented temperature, pressure, composition, impurities, substrate and thermal history. A color or appearance alone is insufficient. |
| Evidence & scope | Evidence & scope: [AL2, AL4, AL10, AL17]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| C-12 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| C-13 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| C-14 | 5,730 y | Solid (expected elemental chemical form, not isotope-specific observation) | ? | ? |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Naturally occurring material may contain low-activity radionuclide(s); example C-14. Many laboratory-enriched/activated forms are different. |
|---|---|
| External radiation — near-term | Typical small natural-composition samples are not expected to cause prompt external radiation injury; this is NOT a clearance for concentrated or activated material. Specific example: C-14 is a low-energy beta emitter; usually limited external skin penetration. |
| External radiation — longer-term | Cumulative external dose is usually low for ordinary samples but may need assessment for unusual amounts or radioisotope-enriched materials. |
| Internal exposure — near-term | Natural radionuclides may enter the body with dust, gases or soluble materials. Immediate radiologic symptoms are not expected at background-level intake; chemical toxicity may be separate. C-14-labelled CO2 or particulates can cause internal beta dose; risk depends on intake and metabolism. |
| Internal exposure — longer-term | Radiation-induced effects depend on committed organ dose and retention, not merely the element name; higher intakes can increase long-term cancer risk. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 15 recorded: 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Brief touch of intact graphite/diamond usually has no toxic effect; powders can dry or irritate the skin. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Very low | Dryness or irritation can occur with repeated carbon powders; intact graphite or diamond has little dermal toxicity. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Moderate | Graphite/carbon-black dust may irritate airways; bulk diamond or graphite is not inhalable. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | High | High sustained respirable exposures to some carbon dusts may impair lungs; risk differs by carbon allotrope and impurities. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Graphite/diamond are stable in ordinary air; burning carbon forms CO2 and, with incomplete combustion, CO; carbon dust is combustible. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | No ordinary chemical reaction with water; carbon materials may adsorb water or disperse as powder. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Low | A small accidental amount of clean bulk material is not expected to cause characteristic acute chemical poisoning; particles can still obstruct, irritate or cause choking. | Do not allow ingestion; wash hands and separate food from lab work. CONDITION: Not evidence that the element is edible. |
| Eye exposure | Moderate | Solid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal. | Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity. |
| Skin absorption | Low | No established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure. | Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness. |
| Fire and explosion | High | Some elemental forms burn in air (carbon dust/soot or sulfur); dispersed dust can increase fire hazard. | Keep powders away from ignition; control dust and oxidizers. CONDITION: Diamond/graphite/sulfur allotropes and forms differ. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Moderate | Environmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient. | Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Moderate | Crystalline or brittle pieces can fracture into sharp fragments; processing produces particulate. | Cut/cleave behind guards; avoid dust and chips. CONDITION: Form-dependent; diamond is hard, graphite soft. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Measure graphite versus other carbon-allotrope electrical behavior |
| Expected observation / output | Resistivity, Raman D/G signals. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Document exact allotrope, crystalline/amorphous phase, dopant level and surface finish. |
| Sample preparation & apparatus | Clean tools, substrate/sample fixture, four-probe/Raman/XRD as appropriate; manage surface contamination. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Coal, hydrocarbons, biomass; high-purity graphite and synthetic diamond produced industrially. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | Diamond, graphite, graphene, amorphous carbon and nanotubes differ drastically in bonding and properties. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Select temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes. |
| Electrical / magnetic / optical measurement | Raman spectroscopy for allotropes/defects; combustion analysis for carbon content. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Never infer properties from 'carbon' alone: allotrope, morphology and defects control performance. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Allotrope and defect content dominate measured properties. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Measure graphite versus other carbon-allotrope electrical behavior. |
| Measurable evidence | Resistivity, Raman D/G signals. Carbon allotrope/phase; defect proxies, not total elemental purity. |
| Measurement pathway (candidate) | Raman plus XRD for certified carbon specimen. |
| Specimen & interpretation boundary | Allotrope and defect content dominate measured properties. |
| Known failure/false conclusion | Different allotropes, laser heating, fluorescence and impurity-derived peaks. |
| Evidence required BEFORE use | NIST structural reference standards + property-specific method report [R10,R17]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Nitrogen |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: