Nitrogen
Experimental chemistry • properties • laboratory science
N2 triple bond makes gas relatively inert; reactive nitrides, ammonia and nitrogen oxides are distinct.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 7 |
|---|---|
| Symbol / type | N · Nonmetal • Gas at room temperature • atomic mass: 14.007 (rounded) |
| Elemental form | Gas | selected oxidation states -3,+3,+5 |
| Chemical identity | N2 triple bond makes gas relatively inert; reactive nitrides, ammonia and nitrogen oxides are distinct. |
| Occurrence and production | Air separation for N2; ammonia production from N2 and H2. |
| Useful applications | Inert atmospheres, cryogenics, fertilizer chemistry and nitriding processes. |
| Analytical characterization | GC for gas composition; oxygen analyzer for atmosphere control; combustion analysis for N in solids. |
| Research / quality note | Nitrogen is chemically inert in many settings but not a breathable substitute for air. |
| Oxidation and chemical forms | Selected: -3 / +3 / +5. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Gas |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 63.172 K (-209.9780 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 77.36 K (-195.7900 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | α-N₂ → β-N₂: 35.620 K |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| α-N2 | Gas (elemental baseline; named form stability can differ) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| β-N2 | Gas (elemental baseline; named form stability can differ) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Polymeric nitrogen (cg-N and related high-pressure phases) | Gas (elemental baseline; named form stability can differ) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | Selected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 35.620 K. These are phase boundaries, not safe heating instructions. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| N-13 | 9.97 min | Gas (expected elemental chemical form, not isotope-specific observation) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| N-14 | Stable; no observed radioactive decay | Gas (expected elemental chemical form, not isotope-specific observation) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| N-15 | Stable; no observed radioactive decay | Gas (expected elemental chemical form, not isotope-specific observation) | ≈63.172 K(-209.9780 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈77.36 K(-195.7900 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: N-13. The BLUE entries refer ONLY to stable nuclides, not to N-13. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 16 recorded: 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Gas minimal skin effect; liquid nitrogen frostbite. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Very low | Nitrogen gas does not cause chronic skin toxicity; repeated liquid-nitrogen cold burns can cause scarring. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Critical | At high concentration, oxygen is displaced and asphyxiation can develop without irritation or warning. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | No cumulative nitrogen toxicity; serious or prolonged hypoxia can cause permanent brain injury. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Very low | N2 is largely unreactive in air under ambient conditions; nitrogen oxides form under high-temperature/electrical conditions. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | No chemical reaction; nitrogen dissolves slightly in water. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Low | Ordinary gas exposure is inhalation rather than ingestion; swallowing compressed/liquefied gas or cold liquid may cause physical injury. | Use appropriate gas/cryogenic controls; ingestion of gas is not a routine exposure pathway. CONDITION: No nutritional or therapeutic claim. |
| Eye exposure | Low | Ambient gas is not ordinarily an ocular chemical irritant; high-pressure gas jets and liquefied gas can physically damage eyes. | Never direct compressed gas at eyes; cryogenic eye protection if liquefied. CONDITION: Gas under pressure or extreme cold changes risk. |
| Skin absorption | Low | Room-temperature gas has no ordinary cutaneous uptake causing systemic toxicity; pressurized/liquefied forms can injure by impact or cold. | Prevent gas jets and cold-liquid splashes. CONDITION: Not an inhalation safety statement. |
| Fire and explosion | Moderate | Fire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals. | Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility. |
| Heating and fumes | Moderate | Warming liquefied or pressurized gas can generate rapid expansion/overpressure; oxygen or hydrogen has additional chemical hazards. | Pressure relief and cylinder/cryogenic engineering; avoid heating sealed containers. CONDITION: Only if confined/cold/pressurized. |
| Chemical incompatibility | Very low | Ordinary nitrogen gas is chemically unreactive with common reagents at ambient conditions; high pressure or oxygen displacement are separate. | Prevent oxygen-deficient atmospheres and pressure failures. CONDITION: High-temperature/high-energy nitrogen chemistry differs. |
| Storage and pressure | High | Compressed or liquefied gas vessels may rupture, leak, displace oxygen or generate rapid cold expansion; reactive gases add toxicity/fire. | Use compliant rated cylinders, restraint, compatible regulators, relief devices, ventilation and leak planning. CONDITION: A small unpressurized room-temperature amount is different. |
| Bioaccumulation | Very low | These ordinary gases do not normally bioaccumulate as persistent chemical toxicants; oxygen deprivation/oxidation hazards are separate. | Evaluate atmosphere and pressure, not a tissue accumulation model. CONDITION: Radioactive gas isotopes (e.g., Kr-85) are different. |
| Reproductive/developmental effects | Low | No established reproductive toxicity from normal ambient exposure to the pure gas; severe oxygen depletion or excessive oxygen are separate acute hazards. | Control occupational atmosphere and pressure rather than assume a developmental toxicant. CONDITION: Not permission to breathe concentrated gases. |
| Environmental effects | Low | Pure common gas has low direct persistence as a toxic aquatic solute, but large releases can alter oxygen availability or fire conditions. | Ventilate controlled spaces; environmental release permitting when required. CONDITION: Not equivalent to no occupational danger. |
| Cryogenic effects | Critical | Liquefied/very cold gas causes frostbite and rapid boil-off; inert gases can displace oxygen and overpressurize closed systems. | Ventilation/O2 monitoring where needed, face protection, pressure relief and cryogen training. CONDITION: Only when liquefied/cryogenic. |
| Mechanical and pressure hazards | High | High-pressure gas jets/cylinder failure can injure or propel fragments; liquid gases add cold-burn risk. | Secure cylinders, approved regulators, guards and release controls. CONDITION: Physical pressure hazard is independent of gas toxicity. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Supervised apparatus / trained handling — Gas-cylinder, oxygen-deficiency, pressure and/or fume risks require engineered controls. |
|---|---|
| Research objective | Verify nitrogen purity and oxygen contamination in an inert-gas system |
| Expected observation / output | O2 ppm and gas purity. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Certified gas in engineered system or factory-sealed optical reference cell, not a loose solid. |
| Sample preparation & apparatus | Approved gas manifold, pressure regulator, gas purity sensor and leak checks; check oxygen-deficiency risk. |
| Atmosphere and compatibility | Known gas composition, temperature, regulator condition and chamber pressure; monitor oxygen displacement where relevant. |
| Production / refining context | Occurrence/production context: Air separation for N2; ammonia production from N2 and H2. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | N2 triple bond makes gas relatively inert; reactive nitrides, ammonia and nitrogen oxides are distinct. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Use regulated pressure/temperature ranges supplied by certified equipment; record flow and gas composition. |
| Electrical / magnetic / optical measurement | GC for gas composition; oxygen analyzer for atmosphere control; combustion analysis for N in solids. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Nitrogen is chemically inert in many settings but not a breathable substitute for air. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | A nominal N2 atmosphere is not automatically oxygen-free. |
| Teaching / research levels | School: sealed demonstration/recorded spectra only. University: managed gas analysis. Research: validated gas-phase and surface studies. |
| Preservation & data archive | Approved cylinder or sealed reference cell, correct segregation, securement and leak checks; no improvised storage. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T2 • closed certified gas/optical system and trained operator |
|---|---|
| Practical experiment question | Verify nitrogen purity and oxygen contamination in an inert-gas system. |
| Measurable evidence | O2 ppm and gas purity. Gas purity, partial pressure or emission lines. |
| Measurement pathway (candidate) | Calibrated gas analysis or certified sealed optical emission reference. |
| Specimen & interpretation boundary | A nominal N2 atmosphere is not automatically oxygen-free. |
| Known failure/false conclusion | Leaks, carrier gas purity, pressure, adsorption and detector background; O2 deficiency where relevant. |
| Evidence required BEFORE use | Certified gas/reference lamp certificates + traceable calibration [R11]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Oxygen |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: