Chlorine
Experimental chemistry • properties • laboratory science
Cl2 oxidant; chloride is stable common anion; chlorination reactions vary by substrate.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 17 |
|---|---|
| Symbol / type | Cl · Halogen • Gas at room temperature • atomic mass: 35.453 (rounded) |
| Elemental form | Gas | selected oxidation states -1,+1,+5 |
| Chemical identity | Cl2 oxidant; chloride is stable common anion; chlorination reactions vary by substrate. |
| Occurrence and production | Electrolysis of brine in chlor-alkali industry. |
| Useful applications | Water treatment and chemical synthesis; PVC production uses chlorine-derived feedstocks. |
| Analytical characterization | Ion chromatography for chloride; colorimetry for free/total chlorine; online gas detection. |
| Research / quality note | Chlorine gas, chloride salt and hypochlorite have different properties. |
| Oxidation and chemical forms | Selected: -1 / +1 / +5. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Gas |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 172.2 K (-100.95 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 239.11 K (-34.04 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Gas (elemental baseline; named form stability can differ) | ≈172.2 K(-100.95 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈239.11 K(-34.04 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Cl-35 | Stable; no observed radioactive decay | Gas (expected elemental chemical form, not isotope-specific observation) | ≈172.2 K(-100.95 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈239.11 K(-34.04 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Cl-36 | 301,000 y | Gas (expected elemental chemical form, not isotope-specific observation) | ≈172.2 K(-100.95 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈239.11 K(-34.04 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Cl-37 | Stable; no observed radioactive decay | Gas (expected elemental chemical form, not isotope-specific observation) | ≈172.2 K(-100.95 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈239.11 K(-34.04 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Cl-36. The BLUE entries refer ONLY to stable nuclides, not to Cl-36. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 24 recorded: 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Critical | Gas or liquid causes corrosive irritation/burns. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Critical | Corrosive burns can heal with scarring; repeated low-level vapor exposure irritates skin and mucosa. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Critical | Chlorine gas can cause coughing, choking and delayed pulmonary edema. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Repeated chlorine exposure or severe single episodes may leave persistent airway hyperreactivity. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Critical | Chlorine is a reactive oxidizing gas; in humid air it forms irritating/corrosive species; does not simply remain harmless as it disperses. | Interpret together with storage, ignition and process conditions. |
| Water contact | Critical | Chlorine dissolves and partly hydrolyzes in water to hydrochloric acid and hypochlorous acid; the mixture is corrosive. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Critical | Corrosive elemental halogen causes severe mouth, throat and gastrointestinal tissue injury; associated inhalation may dominate for gases. | Use a closed compatible system; emergency response and immediate medical evaluation for exposure. CONDITION: F2/Cl2 gases; Br2 volatile liquid. |
| Eye exposure | Critical | Elemental halogen vapor or liquid can cause severe eye irritation/corrosive damage, potentially permanent vision injury. | Closed equipment plus splash/face protection and accessible eyewash; emergency medical care. CONDITION: Gas or liquid form makes exposure rapid. |
| Skin absorption | Critical | Halogen exposure can cause serious chemical burns on skin; penetration/uptake depends on compound formed and exposure. | Prevent gas/liquid contact; suitable rated protective barriers and emergency showers. CONDITION: Corrosive effect may dominate absorption. |
| Fire and explosion | High | Elemental halogen is not normally flammable but is oxidizing/reactive and can intensify or cause fire with incompatible materials. | Strict segregation from fuels, reducers and reactive metals. CONDITION: Not an ordinary combustible fuel. |
| Heating and fumes | Critical | Heating increases volatilization of corrosive halogen or vapor and raises risks of severe eye/airway injury. | Closed temperature-rated corrosion-resistant system. CONDITION: F2/Cl2 gases, Br2 liquid, I2 solid. |
| Chemical incompatibility | Critical | Strong oxidizing halogen reacts with metals, reducers, organics and many other incompatible materials; corrosive gases may form. | Chemical compatibility matrix for every contacted seal, reagent and exhaust path. CONDITION: Reagent-specific severity. |
| Storage and pressure | Critical | Compressed or liquefied gas vessels may rupture, leak, displace oxygen or generate rapid cold expansion; reactive gases add toxicity/fire. | Use compliant rated cylinders, restraint, compatible regulators, relief devices, ventilation and leak planning. CONDITION: A small unpressurized room-temperature amount is different. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Critical | Halogen gas/liquid releases can injure plants and aquatic life or form harmful reactive products in water/air. | Prevent vented releases; compatible scrubbing and waste capture by trained staff. CONDITION: Chemical release, not radiological. |
| Cryogenic effects | Moderate | Refrigerated or molten/solid form may cause thermal injury; corrosive halogen exposure remains the main hazard. | Control cold/hot handling and corrosion-resistant containment. CONDITION: Not necessarily below conventional cryogenic temperature. |
| Mechanical and pressure hazards | High | High-pressure gas jets/cylinder failure can injure or propel fragments; liquid gases add cold-burn risk. | Secure cylinders, approved regulators, guards and release controls. CONDITION: Physical pressure hazard is independent of gas toxicity. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Professional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment. |
|---|---|
| Research objective | Determine chlorine chemistry through a certified chloride reference |
| Expected observation / output | Ion chromatography and recovery. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Certified gas in engineered system or factory-sealed optical reference cell, not a loose solid. |
| Sample preparation & apparatus | Approved gas manifold, pressure regulator, gas purity sensor and leak checks; check oxygen-deficiency risk. |
| Atmosphere and compatibility | Known gas composition, temperature, regulator condition and chamber pressure; monitor oxygen displacement where relevant. |
| Production / refining context | Context: Electrolysis of brine in chlor-alkali industry. For teaching, use certified prepared materials; industrial extraction is not a bench recipe. |
| Reaction, oxidation & corrosion | Cl2 oxidant; chloride is stable common anion; chlorination reactions vary by substrate. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Use regulated pressure/temperature ranges supplied by certified equipment; record flow and gas composition. |
| Electrical / magnetic / optical measurement | Ion chromatography for chloride; colorimetry for free/total chlorine; online gas detection. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Chlorine gas, chloride salt and hypochlorite have different properties. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Chloride salts are not a substitute for elemental Cl2 hazard evaluation. |
| Teaching / research levels | School: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol. |
| Preservation & data archive | Approved cylinder or sealed reference cell, correct segregation, securement and leak checks; no improvised storage. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T3 • specialized controlled professional facility; no open handling |
|---|---|
| Practical experiment question | Determine chlorine chemistry through a certified chloride reference. |
| Measurable evidence | Ion chromatography and recovery. Halide concentration, NOT free halogen element. |
| Measurement pathway (candidate) | Certified halide standard; IC or appropriate species-selective method. |
| Specimen & interpretation boundary | Chloride salts are not a substitute for elemental Cl2 hazard evaluation. |
| Known failure/false conclusion | Leaks, carrier gas purity, pressure, adsorption and detector background; O2 deficiency where relevant. |
| Evidence required BEFORE use | Certified gas/reference lamp certificates + traceable calibration [R11]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Argon |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: