Sulfur
Experimental chemistry • properties • laboratory science
S8 and other allotropes; oxidation states span -II to +VI.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 16 |
|---|---|
| Symbol / type | S · Nonmetal • Solid at room temperature • atomic mass: 32.067 (rounded) |
| Elemental form | Solid | selected oxidation states -2,+4,+6 |
| Chemical identity | S8 and other allotropes; oxidation states span -II to +VI. |
| Occurrence and production | Recovered mainly from natural-gas/oil desulfurization; volcanic/mineral sources. |
| Useful applications | Sulfuric acid production, vulcanization and fertilizers. |
| Analytical characterization | Combustion sulfur analysis; XRF; ion chromatography for sulfate. |
| Research / quality note | Oxidation to SO2/SO3 changes exposure and corrosion; solid sulfur is not sulfide gas. |
| Bench properties | Approx. melting 115.2 °C; density 2.07 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: -2 / +4 / +6. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 392.5 K (119.35 °C) (β-monoclinic sulfur (S8) ONLY; not universal bulk element melting) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 717.75 K (444.60 °C) |
| Sublimation (solid → gas) near 1 atm | ? |
| Additional solid–solid transitions | α-S₈ → β-S₈: 368.43 K; sulfur has multiple forms |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | Sulfur: multiple S₈ and polymeric forms; form-specific transitions; see form-specific table. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| α-S8 (orthorhombic) | Solid (form/stability dependent) | α → β 368.43 ± 0.10 K; metastable α-melting report ~386 ± 6 K | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| β-S8 and γ-S8 (monoclinic) | Solid (form/stability dependent) | β-S₈ melts ~392.5 ± 4 K; γ-S₈ melts ~381.8 ± 0.3 K; β→γ ~388.31 K (reported) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Other cyclic sulfur molecules (S6, S7, S9, S10, S11, S12, S13–S15, S18, S20; ring-family examples) | Solid (elemental baseline; named form stability can differ) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Polymeric / plastic sulfur (catena-μ-S) | Solid (form/stability dependent) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
| Amorphous, fibrous and vitreous sulfur | Solid (form/stability dependent) | Amorphous S melting ~451.5 ± 11 K; fibrous ~377 K; glass ~350 K (different materials, not one point) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Named forms noted in chapter | S8 and other allotropes; oxidation states span -II to +VI. |
|---|---|
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
| Transition note | Selected evaluated transitions at ~1 atm (NIST TN 2312): α-S8 → β-S8 = 368.43 K. These are phase boundaries, not safe heating instructions. |
| Laboratory identification | Laboratory identification: use phase-specific powder/single-crystal XRD, Raman or other appropriate spectroscopy, with documented temperature, pressure, composition, impurities, substrate and thermal history. A color or appearance alone is insufficient. |
| Evidence & scope | Evidence & scope: [AL2, AL3, AL7]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| S-32 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| S-33 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| S-34 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| S-35 | 87.4 d | Solid (expected elemental chemical form, not isotope-specific observation) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| S-36 | Stable; no observed radioactive decay | Solid (expected elemental chemical form, not isotope-specific observation) | ≈392.5 K(119.35 °C) (β-monoclinic sulfur (S8) FORM reference; NOT isotope-specific or applicable to every allotrope) | ≈717.75 K(444.60 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: S-35. The BLUE entries refer ONLY to stable nuclides, not to S-35. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 24 recorded: 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | Solid low acute contact hazard; heated/melted burns. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Very low | Repeated sulfur dust may cause mild irritation; heated molten sulfur can produce lasting burns. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Moderate | Sulfur dust causes cough/irritation; burning sulfur makes sulfur dioxide, a potent respiratory irritant. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | High | Repeated sulfur dioxide inhalation may aggravate asthma or cause persistent respiratory symptoms; pure solid sulfur differs. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | High | Bulk sulfur is normally air-stable; heated sulfur burns to sulfur dioxide (SO2); fine dust can form explosive clouds. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | Elemental sulfur is essentially insoluble and does not normally react with cold water. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Moderate | Ingestion of elemental particles is not a validated safe exposure; toxicity depends on solubility, amount, particle size and transformations in stomach acid. | Prevent hand-to-mouth exposure; use elemental-form SDS for any incident. CONDITION: Screening level only. |
| Eye exposure | Moderate | Solid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal. | Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity. |
| Skin absorption | Low | No established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure. | Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness. |
| Fire and explosion | High | Some elemental forms burn in air (carbon dust/soot or sulfur); dispersed dust can increase fire hazard. | Keep powders away from ignition; control dust and oxidizers. CONDITION: Diamond/graphite/sulfur allotropes and forms differ. |
| Heating and fumes | Moderate | Heating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity. | Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes. |
| Chemical incompatibility | Moderate | Strong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case. | Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | Uncertain | No reliable general claim about long-term tissue accumulation can be made for every form of this element. | Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention. |
| Reproductive/developmental effects | Uncertain | Insufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling. | Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green. |
| Environmental effects | Moderate | Environmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient. | Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Low | Small intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential. | Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | School observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate. |
|---|---|
| Research objective | Differentiate elemental sulfur forms and thermal transitions |
| Expected observation / output | DSC peaks, Raman/XRD changes. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Clean sample mount and correctly calibrated method selected from the target observable; confirm holder compatibility. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Occurrence/production context: Recovered mainly from natural-gas/oil desulfurization; volcanic/mineral sources. Compare supply grade, supplier CoA and measured composition before choosing a refining route. |
| Reaction, oxidation & corrosion | S8 and other allotropes; oxidation states span -II to +VI. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 115.2 °C and density 2.07 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | Combustion sulfur analysis; XRF; ion chromatography for sulfate. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Oxidation to SO2/SO3 changes exposure and corrosion; solid sulfur is not sulfide gas. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Burning can release SO2; heating and vapor effects must be separately assessed. |
| Teaching / research levels | School: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study. |
| Preservation & data archive | Use labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T1/T2 • supervised accessible specimen when form-specific risk assessment permits |
|---|---|
| Practical experiment question | Differentiate elemental sulfur forms and thermal transitions. |
| Measurable evidence | DSC peaks, Raman/XRD changes. Phase/allotrope plus total content when necessary. |
| Measurement pathway (candidate) | Raman/XRD plus elemental assay on suitable certified form. |
| Specimen & interpretation boundary | Burning can release SO2; heating and vapor effects must be separately assessed. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Chlorine |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: