ELEMENT 053 / HALOGEN
53IATOMIC NUMBER · SYMBOL

Iodine

Experimental chemistry • properties • laboratory science

I2 sublimates; I(-I)/I(+I,+V) chemistry and thyroid-specific biological relevance.

Atomic no. 53HalogenSolid at room conditions
Explore profile
IMAGE PLACEHOLDERIReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number53
Symbol / typeI · Halogen • Solid at room temperature • atomic mass: 126.904 (rounded)
Elemental formSolid | selected oxidation states -1,+1,+5
Chemical identityI2 sublimates; I(-I)/I(+I,+V) chemistry and thyroid-specific biological relevance.
Occurrence and productionIodide brines and seawater resources; oxidized to iodine.
Useful applicationsIodinated contrast/media compounds, disinfection and pharmaceutical synthesis.
Analytical characterizationIon chromatography for iodide/iodate; ICP-MS for total iodine.
Research / quality noteI2 vapor, iodide in diet and radioactive I-131 require separate consideration.
Bench propertiesApprox. melting 113.7 °C; density 4.93 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: -1 / +1 / +5. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)386.8 K (113.65 °C)
Elemental-bulk boiling / gas formation (near 1 atm)457.4 K (184.25 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈386.8 K(113.65 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈457.4 K(184.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Iodine is molecular I2 in its ordinary solid; very-high-pressure monatomic metallic phases have been experimentally identified. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~386.8 K; generic gas reference ~457.4 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
I-12559.4 dSolid (expected elemental chemical form, not isotope-specific observation)≈386.8 K(113.65 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈457.4 K(184.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
EC/x-rays
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~386.8 K; liquid between ~386.8 and ~457.4 K; gas above ~457.4 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

I-127Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈386.8 K(113.65 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈457.4 K(184.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~386.8 K; liquid between ~386.8 and ~457.4 K; gas above ~457.4 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

I-1318.02 dSolid (expected elemental chemical form, not isotope-specific observation)≈386.8 K(113.65 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈457.4 K(184.25 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-/gamma
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~386.8 K; liquid between ~386.8 and ~457.4 K; gas above ~457.4 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: I-131. The BLUE entries refer ONLY to stable nuclides, not to I-131.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. Specific example: I-131 emits beta and gamma radiation; accessible high-activity material can give external dose.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. Radioiodine may accumulate in the thyroid and deliver a concentrated internal dose; late thyroid risk is a key concern.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 37 recorded: 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateHighElemental iodine can stain and irritate skin; prolonged contact may produce chemical burns.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedHighRepeated iodine contact can cause dermatitis; absorbed iodine from exposures may affect thyroid function.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateCriticalIodine vapor causes burning throat, cough and irritation.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalProlonged excess iodine exposure can alter thyroid function; radioactive iodine adds thyroid radiation dose.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighIodine slowly sublimates into a colored, irritating vapor even at room temperature; oxidizing reactivity depends on materials.Interpret together with storage, ignition and process conditions.
Water contactLowSlightly soluble in pure water with weak hydrolysis; iodine solutions remain irritating and oxidizing.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionHighElemental iodine crystals/vapor can irritate or injure mucosa and cause systemic iodine-related effects after significant intake.Prevent access to crystals, dust and vapors; use controlled handling and exposure-specific medical review. CONDITION: Different from nutritional iodide intake.
Eye exposureHighElemental iodine crystals, dust or vapor can cause eye irritation and potentially significant damage.Enclose vapors and prevent crystal/dust release; eye protection and eyewash. CONDITION: Molecular iodine, not iodide.
Skin absorptionModerateIodine crystals/contact can irritate and stain skin; absorption may contribute to thyroid effects with significant repeated exposure.Prevent iodine vapor/crystal contact; gloves assessed for compatibility. CONDITION: Iodine compounds have different exposure properties.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesCriticalHeating increases volatilization of corrosive halogen or vapor and raises risks of severe eye/airway injury.Closed temperature-rated corrosion-resistant system. CONDITION: F2/Cl2 gases, Br2 liquid, I2 solid.
Chemical incompatibilityModerateStrong acids, bases, oxidizers or halogens may corrode or transform elemental material; the reaction must be checked case by case.Verify exact pairwise compatibility and expected evolved gases before mixing. CONDITION: Not a general permission to mix.
Storage and pressureModerateIodine sublimation/vapor can escape poorly sealed jars, contaminating cabinet surfaces and irritating eyes/airways.Use validated chemical-compatible vapor-tight packaging and secondary enclosure. CONDITION: At ambient temperature iodine can volatilize.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsCriticalHalogen gas/liquid releases can injure plants and aquatic life or form harmful reactive products in water/air.Prevent vented releases; compatible scrubbing and waste capture by trained staff. CONDITION: Chemical release, not radiological.
Cryogenic effectsModerateRefrigerated or molten/solid form may cause thermal injury; corrosive halogen exposure remains the main hazard.Control cold/hot handling and corrosion-resistant containment. CONDITION: Not necessarily below conventional cryogenic temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierProfessional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment.
Research objectiveMeasure iodine in a certified iodide specimen via spectroscopy
Expected observation / outputUV–Vis or ion assay. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound.
Sample preparation & apparatusEnclosed instrument or preprepared certified reference; exposure and waste control are prerequisites.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextContext: Iodide brines and seawater resources; oxidized to iodine. For teaching, use certified prepared materials; industrial extraction is not a bench recipe.
Reaction, oxidation & corrosionI2 sublimates; I(-I)/I(+I,+V) chemistry and thyroid-specific biological relevance. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseScreening context: approx. melt 113.7 °C and density 4.93 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified.
Electrical / magnetic / optical measurementIon chromatography for iodide/iodate; ICP-MS for total iodine. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationI2 vapor, iodide in diet and radioactive I-131 require separate consideration. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallElemental I2 vapor hazard differs from iodide.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveCertified containment and segregated inventory with contamination monitoring and disposal protocol.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT1/T2 • supervised accessible specimen when form-specific risk assessment permits
Practical experiment questionMeasure iodine in a certified iodide specimen via spectroscopy.
Measurable evidenceUV–Vis or ion assay. Halide concentration, NOT free halogen element.
Measurement pathway (candidate)Certified halide standard; IC or appropriate species-selective method.
Specimen & interpretation boundaryElemental I2 vapor hazard differs from iodide.
Known failure/false conclusionHalide species versus element, volatilization, container interaction and reagent blanks.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteXenon
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: