ELEMENT 052 / METALLOID
52TeATOMIC NUMBER · SYMBOL

Tellurium

Experimental chemistry • properties • laboratory science

Te(IV)/Te(VI), useful thermoelectric and semiconductor chemistry.

Atomic no. 52MetalloidSolid at room conditions
Explore profile
IMAGE PLACEHOLDERTeReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number52
Symbol / typeTe · Metalloid • Solid at room temperature • atomic mass: 127.600 (rounded)
Elemental formSolid | selected oxidation states -2,+4,+6
Chemical identityTe(IV)/Te(VI), useful thermoelectric and semiconductor chemistry.
Occurrence and productionMainly recovered from copper anode slimes.
Useful applicationsCdTe solar cells, Bi2Te3 thermoelectrics and alloying.
Analytical characterizationICP-MS, XRD for thermoelectric phases, Seebeck coefficient tests.
Research / quality noteDevice behavior depends on compound phase and dopant concentration.
Bench propertiesApprox. melting 449.5 °C; density 6.24 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: -2 / +4 / +6. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)722.72 K (449.57 °C)
Elemental-bulk boiling / gas formation (near 1 atm)1261 K (987.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Crystalline trigonal telluriumSolid (elemental baseline; named form stability can differ)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Helical chain structure at ordinary conditions. LAB: Semiconductor with anisotropic properties.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~722.72 K; generic gas reference ~1261 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Amorphous telluriumSolid (elemental baseline; named form stability can differ)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Noncrystalline elemental films and quenched preparations. LAB: Not a single defined crystalline allotrope.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~722.72 K; generic gas reference ~1261 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

High-pressure Te-II, Te-III, Te-IV and related phasesSolid (elemental baseline; named form stability can differ)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Several pressure-driven structures and metallic states are reported. LAB: Experimental identification depends on P–T trajectory; theoretical phase diagrams are not direct verification.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~722.72 K; generic gas reference ~1261 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Tellurene sheets/nanostructuresSolid (elemental baseline; named form stability can differ)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Thin elemental Te sheets may have altered structure; monolayer versus bulk distinctions require microscopy and spectroscopy. LAB: Specialized thin-film phase identification; literature contains multiple growth-dependent motifs. [AL5,AL14]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~722.72 K; generic gas reference ~1261 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: use phase-specific powder/single-crystal XRD, Raman or other appropriate spectroscopy, with documented temperature, pressure, composition, impurities, substrate and thermal history. A color or appearance alone is insufficient.
Evidence & scopeEvidence & scope: [AL14]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Te-120Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-122Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-123Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-124Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-125Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-126Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-128~2.2e24 ySolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
double beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Te-130~7e20 ySolid (expected elemental chemical form, not isotope-specific observation)≈722.72 K(449.57 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1261 K(987.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
double beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~722.72 K; liquid between ~722.72 and ~1261 K; gas above ~1261 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Te-132. The BLUE entries refer ONLY to stable nuclides, not to Te-132.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.
Nuclear assessment noteNUCLEAR STATUS: Naturally occurring radioisotopes are known or may have extremely long decay half-lives. Never infer “stable” solely from natural abundance.

Isotope mass-number inventory (reference registry; not complete ENSDF): 38 recorded: 105, 106, 107, 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118, 119, 120, 121, 122, 123, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateModerateMay irritate; absorption can cause characteristic breath odour.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedModerateRepeated elemental tellurium contamination may cause skin irritation or characteristic garlic-like odor in exhaled breath.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighTellurium dust/fume may irritate and cause systemic symptoms at sufficient uptake.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalLong-term effects of tellurium metal aerosols are poorly characterized; industrial compounds need evaluation.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityModerateTellurium is relatively air-stable at room temperature; heating produces tellurium oxides.Interpret together with storage, ignition and process conditions.
Water contactVery lowElemental tellurium has low water solubility and no vigorous cold-water reaction.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateElemental particles may cause gastrointestinal or systemic effects after sufficient intake; soluble compounds generally have distinct absorption.Prevent accidental swallowing; review SDS for particle size and chemistry. CONDITION: Do not infer effects from soluble salts.
Eye exposureModerateSolid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal.Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity.
Skin absorptionLowNo established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure.Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesHighHeating can generate irritating or toxic oxide/metal fumes; hazards are greater than from cold intact metal.Local exhaust and process-specific exposure assessment. CONDITION: Metal and formed oxide should be assessed separately.
Chemical incompatibilityModerateOxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products.Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides.
Storage and pressureLowA closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible.Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsHighReleases of metal particles or soluble products can threaten aquatic or terrestrial organisms; toxicity depends on speciation and dose.Contain wastewater and particulate residues; follow waste regulations. CONDITION: Never assume elemental metal dissolves at salt-like rates.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsModerateCrystalline or brittle pieces can fracture into sharp fragments; processing produces particulate.Cut/cleave behind guards; avoid dust and chips. CONDITION: Form-dependent; diamond is hard, graphite soft.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSchool observation to professional testing — Handling only if local assessment deems the chosen form, quantity and method appropriate.
Research objectiveMeasure tellurium phase in a certified semiconductor material
Expected observation / outputXRD/Raman and composition. Predetermine units, calibration basis and appropriate control.
Available physical formDocument exact allotrope, crystalline/amorphous phase, dopant level and surface finish.
Sample preparation & apparatusClean tools, substrate/sample fixture, four-probe/Raman/XRD as appropriate; manage surface contamination.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextOccurrence/production context: Mainly recovered from copper anode slimes. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionTe(IV)/Te(VI), useful thermoelectric and semiconductor chemistry. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseScreening context: approx. melt 449.5 °C and density 6.24 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified.
Electrical / magnetic / optical measurementICP-MS, XRD for thermoelectric phases, Seebeck coefficient tests. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationDevice behavior depends on compound phase and dopant concentration. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallTelluride semiconductors are not elemental tellurium.
Teaching / research levelsSchool: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study.
Preservation & data archiveUse labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT1/T2 • supervised accessible specimen when form-specific risk assessment permits
Practical experiment questionMeasure tellurium phase in a certified semiconductor material.
Measurable evidenceXRD/Raman and composition. Crystal/allotrope or semiconductor composition.
Measurement pathway (candidate)Raman/XRD and appropriate compositional assay.
Specimen & interpretation boundaryTelluride semiconductors are not elemental tellurium.
Known failure/false conclusionSample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteIodine
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: