Lead
Experimental chemistry • properties • laboratory science
Pb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important.
Click a photograph for a larger view. Images are managed in the editor.
Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 82 |
|---|---|
| Symbol / type | Pb · p-block/post-transition element • Solid at room temperature • atomic mass: 207.200 (rounded) |
| Elemental form | Solid | selected oxidation states +2,+4 |
| Chemical identity | Pb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important. |
| Occurrence and production | Galena ores and high-volume battery recycling. |
| Useful applications | Lead-acid batteries, radiation shielding and some specialty alloys. |
| Analytical characterization | XRF for alloys; ICP-MS/OES for contamination; battery electrochemical testing. |
| Research / quality note | Lead compounds, oxidized dust and intact metal present different exposure scenarios. |
| Bench properties | Approx. melting 327.5 °C; density 11.34 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +2 / +4. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Solid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 600.612 K (327.46 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 2022 K (1748.85 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Solid (elemental baseline; named form stability can differ) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Pb-204 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pb-206 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pb-207 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pb-208 | Half-life/status not independently verified here | Solid (expected elemental chemical form, not isotope-specific observation) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Pb-210 | 22.2 y | Solid (expected elemental chemical form, not isotope-specific observation) | ≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Pb-210. The BLUE entries refer ONLY to stable nuclides, not to Pb-210. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. Specific example: Pb-210 emits low-energy beta radiation; daughter products can complicate an exposure assessment. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. Radiologic and chemical lead toxicity can coexist; chronic uptake may affect bone and other tissues. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 38 recorded: 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Very low | An intact lead piece may cause no immediate skin symptoms; deposited lead dust can be transferred to the mouth. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Moderate | Repeated lead contact contaminates hands and may lead to ingestion; elemental lead has limited intact-skin uptake. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | High | Dust/fume exposure can occur without immediate symptoms; high exposure may cause abdominal or neurologic effects. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Lead can harm nervous system, kidneys, blood pressure and reproduction; exposure is especially hazardous to children/fetuses. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Moderate | Lead forms protective oxide/carbonate layers in air, often slowing further corrosion. | Interpret together with storage, ignition and process conditions. |
| Water contact | Low | Pure water causes limited immediate reaction; contaminated/acidic water can leach soluble lead over time. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | High | Swallowed lead dust or fragments may contribute absorbed lead; cumulative exposure affects nervous system, blood, kidneys and reproduction. | Prevent contaminated hands/surfaces; use wet cleanup and blood-lead surveillance when indicated. CONDITION: Absorption depends on particle size, age and chemical species. |
| Eye exposure | Moderate | Dust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms. | Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye. |
| Skin absorption | Low | Clean bulk metal does not readily penetrate intact skin; contamination on hands can be swallowed, and soluble compounds behave differently. | Prevent contamination and hand-to-mouth transfer; wash with suitable method. CONDITION: Different from skin contact with salts. |
| Fire and explosion | Low | No usual bulk-element ignition hazard at ambient conditions; other fire hazards from powders or neighboring reagents remain. | Keep away from incompatible reactive chemicals; ensure standard fire protection. CONDITION: Common bulk form. |
| Heating and fumes | High | Hot lead produces airborne lead-containing fume/oxide; cumulative exposure harms nervous, renal and reproductive systems. | Local exhaust, occupational exposure control and no food contamination. CONDITION: Bulk cool lead is a different exposure. |
| Chemical incompatibility | Moderate | Oxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products. | Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides. |
| Storage and pressure | Low | A closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible. | Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe. |
| Bioaccumulation | Critical | Absorbed lead can persist in bone for years and contribute long-term neurologic, renal and reproductive toxicity. | Prevent chronic uptake, dust ingestion and workplace contamination; use biomonitoring when indicated. CONDITION: Human lead retention, not a pure-solid-touch effect. |
| Reproductive/developmental effects | Critical | Established lead exposure can impair fertility and fetal/child neurodevelopment; even relatively low cumulative exposures matter. | Strict dust-control and reproductive-health workplace review; comply with applicable lead standards. CONDITION: Absorbed lead dose, not simply holding a clean sealed metal. |
| Environmental effects | Critical | Lead/cadmium contamination persists in soils/sediments and can poison wildlife or enter food chains. | Capture dust and residues; regulated hazardous waste and environmental controls. CONDITION: Bioavailability and compounds vary. |
| Cryogenic effects | Low | Element does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally. | Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature. |
| Mechanical and pressure hazards | Moderate | Dense or heavy metal pieces can cause impact/crush injury if dropped; machining produces sharp swarf. | Secure mounts and lifting procedures; avoid loose shavings. CONDITION: Physical hazard not a claim of high intrinsic chemical toxicity. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Professional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment. |
|---|---|
| Research objective | Characterize lead corrosion and contamination in certified material |
| Expected observation / output | XRF/ICP, phase and surface state. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Specified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound. |
| Sample preparation & apparatus | Enclosed instrument or preprepared certified reference; exposure and waste control are prerequisites. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Context: Galena ores and high-volume battery recycling. For teaching, use certified prepared materials; industrial extraction is not a bench recipe. |
| Reaction, oxidation & corrosion | Pb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Screening context: approx. melt 327.5 °C and density 11.34 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified. |
| Electrical / magnetic / optical measurement | XRF for alloys; ICP-MS/OES for contamination; battery electrochemical testing. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Lead compounds, oxidized dust and intact metal present different exposure scenarios. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Metallic Pb and soluble Pb species differ in transport. |
| Teaching / research levels | School: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol. |
| Preservation & data archive | Certified containment and segregated inventory with contamination monitoring and disposal protocol. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T3 • specialized controlled professional facility; no open handling |
|---|---|
| Practical experiment question | Characterize lead corrosion and contamination in certified material. |
| Measurable evidence | XRF/ICP, phase and surface state. Trace/major element concentration in specified matrix. |
| Measurement pathway (candidate) | Certified solid or solution CRM by ICP-MS/XRF as matrix permits. |
| Specimen & interpretation boundary | Metallic Pb and soluble Pb species differ in transport. |
| Known failure/false conclusion | Sample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Bismuth |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: