ELEMENT 082 / POST-TRANSITION METAL
82PbATOMIC NUMBER · SYMBOL

Lead

Experimental chemistry • properties • laboratory science

Pb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important.

Atomic no. 82Post-transition metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERPbReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number82
Symbol / typePb · p-block/post-transition element • Solid at room temperature • atomic mass: 207.200 (rounded)
Elemental formSolid | selected oxidation states +2,+4
Chemical identityPb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important.
Occurrence and productionGalena ores and high-volume battery recycling.
Useful applicationsLead-acid batteries, radiation shielding and some specialty alloys.
Analytical characterizationXRF for alloys; ICP-MS/OES for contamination; battery electrochemical testing.
Research / quality noteLead compounds, oxidized dust and intact metal present different exposure scenarios.
Bench propertiesApprox. melting 327.5 °C; density 11.34 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: +2 / +4. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)600.612 K (327.46 °C)
Elemental-bulk boiling / gas formation (near 1 atm)2022 K (1748.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Documented ordinary/reference formSolid (elemental baseline; named form stability can differ)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Lead is fcc in the ordinary bulk elemental solid. LAB: Consult the physical state and source specimen conditions; do not infer another allotrope from oxidation, impurities, phase of matter, particle size, or magnetic ordering alone.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~600.612 K; generic gas reference ~2022 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteNo additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Pb-204Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~600.612 K; liquid between ~600.612 and ~2022 K; gas above ~2022 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Pb-206Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~600.612 K; liquid between ~600.612 and ~2022 K; gas above ~2022 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Pb-207Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~600.612 K; liquid between ~600.612 and ~2022 K; gas above ~2022 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Pb-208Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~600.612 K; liquid between ~600.612 and ~2022 K; gas above ~2022 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Pb-21022.2 ySolid (expected elemental chemical form, not isotope-specific observation)≈600.612 K(327.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈2022 K(1748.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~600.612 K; liquid between ~600.612 and ~2022 K; gas above ~2022 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Pb-210. The BLUE entries refer ONLY to stable nuclides, not to Pb-210.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. Specific example: Pb-210 emits low-energy beta radiation; daughter products can complicate an exposure assessment.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. Radiologic and chemical lead toxicity can coexist; chronic uptake may affect bone and other tissues.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 38 recorded: 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateVery lowAn intact lead piece may cause no immediate skin symptoms; deposited lead dust can be transferred to the mouth.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedModerateRepeated lead contact contaminates hands and may lead to ingestion; elemental lead has limited intact-skin uptake.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighDust/fume exposure can occur without immediate symptoms; high exposure may cause abdominal or neurologic effects.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalLead can harm nervous system, kidneys, blood pressure and reproduction; exposure is especially hazardous to children/fetuses.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityModerateLead forms protective oxide/carbonate layers in air, often slowing further corrosion.Interpret together with storage, ignition and process conditions.
Water contactLowPure water causes limited immediate reaction; contaminated/acidic water can leach soluble lead over time.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionHighSwallowed lead dust or fragments may contribute absorbed lead; cumulative exposure affects nervous system, blood, kidneys and reproduction.Prevent contaminated hands/surfaces; use wet cleanup and blood-lead surveillance when indicated. CONDITION: Absorption depends on particle size, age and chemical species.
Eye exposureModerateDust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms.Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye.
Skin absorptionLowClean bulk metal does not readily penetrate intact skin; contamination on hands can be swallowed, and soluble compounds behave differently.Prevent contamination and hand-to-mouth transfer; wash with suitable method. CONDITION: Different from skin contact with salts.
Fire and explosionLowNo usual bulk-element ignition hazard at ambient conditions; other fire hazards from powders or neighboring reagents remain.Keep away from incompatible reactive chemicals; ensure standard fire protection. CONDITION: Common bulk form.
Heating and fumesHighHot lead produces airborne lead-containing fume/oxide; cumulative exposure harms nervous, renal and reproductive systems.Local exhaust, occupational exposure control and no food contamination. CONDITION: Bulk cool lead is a different exposure.
Chemical incompatibilityModerateOxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products.Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides.
Storage and pressureLowA closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible.Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe.
BioaccumulationCriticalAbsorbed lead can persist in bone for years and contribute long-term neurologic, renal and reproductive toxicity.Prevent chronic uptake, dust ingestion and workplace contamination; use biomonitoring when indicated. CONDITION: Human lead retention, not a pure-solid-touch effect.
Reproductive/developmental effectsCriticalEstablished lead exposure can impair fertility and fetal/child neurodevelopment; even relatively low cumulative exposures matter.Strict dust-control and reproductive-health workplace review; comply with applicable lead standards. CONDITION: Absorbed lead dose, not simply holding a clean sealed metal.
Environmental effectsCriticalLead/cadmium contamination persists in soils/sediments and can poison wildlife or enter food chains.Capture dust and residues; regulated hazardous waste and environmental controls. CONDITION: Bioavailability and compounds vary.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsModerateDense or heavy metal pieces can cause impact/crush injury if dropped; machining produces sharp swarf.Secure mounts and lifting procedures; avoid loose shavings. CONDITION: Physical hazard not a claim of high intrinsic chemical toxicity.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierProfessional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment.
Research objectiveCharacterize lead corrosion and contamination in certified material
Expected observation / outputXRF/ICP, phase and surface state. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound.
Sample preparation & apparatusEnclosed instrument or preprepared certified reference; exposure and waste control are prerequisites.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextContext: Galena ores and high-volume battery recycling. For teaching, use certified prepared materials; industrial extraction is not a bench recipe.
Reaction, oxidation & corrosionPb(II)/Pb(IV), dense soft metal; lead-acid redox is technologically important. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseScreening context: approx. melt 327.5 °C and density 11.34 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified.
Electrical / magnetic / optical measurementXRF for alloys; ICP-MS/OES for contamination; battery electrochemical testing. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationLead compounds, oxidized dust and intact metal present different exposure scenarios. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallMetallic Pb and soluble Pb species differ in transport.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveCertified containment and segregated inventory with contamination monitoring and disposal protocol.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • specialized controlled professional facility; no open handling
Practical experiment questionCharacterize lead corrosion and contamination in certified material.
Measurable evidenceXRF/ICP, phase and surface state. Trace/major element concentration in specified matrix.
Measurement pathway (candidate)Certified solid or solution CRM by ICP-MS/XRF as matrix permits.
Specimen & interpretation boundaryMetallic Pb and soluble Pb species differ in transport.
Known failure/false conclusionSample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteBismuth
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: