ELEMENT 081 / POST-TRANSITION METAL
81TlATOMIC NUMBER · SYMBOL

Thallium

Experimental chemistry • properties • laboratory science

Tl(I) dominates many compounds; chemically resembles K(I); very dense soft metal.

Atomic no. 81Post-transition metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERTlReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number81
Symbol / typeTl · p-block/post-transition element • Solid at room temperature • atomic mass: 204.383 (rounded)
Elemental formSolid | selected oxidation states +1,+3
Chemical identityTl(I) dominates many compounds; chemically resembles K(I); very dense soft metal.
Occurrence and productionByproduct of Pb/Zn sulfide refining.
Useful applicationsLimited specialty optical/electronic and research applications.
Analytical characterizationICP-MS for Tl; XRF in some matrices.
Research / quality noteDo not confuse thallium(I) with safe potassium chemistry; lab access limited.
Oxidation and chemical formsSelected: +1 / +3. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)577 K (303.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)1746 K (1472.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitionsα-Tl → β-Tl: 503 K
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-Tl (hcp)Solid (elemental baseline; named form stability can differ)≈577 K(303.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1746 K(1472.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Ordinary room-temperature crystal. LAB: Strong toxicological constraints separate from phase science.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~577 K; generic gas reference ~1746 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-Tl (bcc)Solid (elemental baseline; named form stability can differ)≈577 K(303.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1746 K(1472.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
High-temperature form; α→β near 503 K. LAB: Never attempt unapproved heating of toxic thallium specimens. [AL3]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~577 K; generic gas reference ~1746 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 503 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Tl-20172.9 hSolid (expected elemental chemical form, not isotope-specific observation)≈577 K(303.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1746 K(1472.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
EC/x-rays
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~577 K; liquid between ~577 and ~1746 K; gas above ~1746 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Tl-203Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈577 K(303.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1746 K(1472.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~577 K; liquid between ~577 and ~1746 K; gas above ~1746 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Tl-205Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈577 K(303.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1746 K(1472.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~577 K; liquid between ~577 and ~1746 K; gas above ~1746 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Tl-201. The BLUE entries refer ONLY to stable nuclides, not to Tl-201.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 37 recorded: 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateHighAn intact sample may not produce immediate skin symptoms; thallium dust/soluble salts can cause systemic poisoning.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedHighRepeated thallium contamination can lead to systemic uptake; soluble salts are especially skin-absorbable.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateCriticalThallium-containing dust can cause severe systemic toxicity, sometimes with delayed symptoms.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedCriticalNeurologic injury and hair loss are classic outcomes of systemic poisoning; consequences depend on form and dose.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityModerateThallium rapidly forms surface oxides when exposed to air; heated processing increases airborne species.Interpret together with storage, ignition and process conditions.
Water contactVery lowBulk thallium can corrode slowly in water/oxygenated conditions, releasing toxic species; no benign water-wash assumption.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionCriticalThallium metal/contamination can produce serious systemic poisoning after ingestion, including neurologic and gastrointestinal effects.Avoid open handling; specialist toxicology response for possible intake. CONDITION: Metal and soluble thallium compounds differ in bioavailability.
Eye exposureModerateDust or particles can irritate the eye; avoid secondary chemical contamination from soluble or oxidized forms.Sealed samples or local capture; ANSI/EN compliant eye protection. CONDITION: Does not imply elemental solid burns the eye.
Skin absorptionCriticalThallium can enter through skin, especially contaminated or damaged skin, and systemic poisoning is possible.Prevent dermal contact; trained handling and decontamination procedures. CONDITION: Absorption varies with material and contamination.
Fire and explosionModerateFire behavior depends strongly on metal powders, temperature, oxygen enrichment or mixing with other chemicals.Check SDS and combustion data before heating or making fine powders. CONDITION: Conservative screening, not proof of combustibility.
Heating and fumesHighHeating can generate irritating or toxic oxide/metal fumes; hazards are greater than from cold intact metal.Local exhaust and process-specific exposure assessment. CONDITION: Metal and formed oxide should be assessed separately.
Chemical incompatibilityModerateOxidizers/acids can change the element into more bioavailable or toxic species; elemental form does not predict products.Review exact chemical pairs and expected products; control emissions. CONDITION: Metal versus ions/oxides.
Storage and pressureLowA closed clean bulk elemental solid ordinarily has modest storage hazard, but broken glass, bad labeling and cross-contamination remain possible.Use compatible labeled, mechanically protected container and segregate reagents. CONDITION: Not an assertion that every compound of this element is safe.
BioaccumulationHighThallium can distribute to multiple tissues and cause prolonged systemic neurologic injury after significant absorbed exposure.Prevent dermal/ingestion/inhalation uptake; specialized medical assessment. CONDITION: Chemical species determines kinetics.
Reproductive/developmental effectsHighSignificant thallium exposure can cause severe systemic toxicity; evidence for precise reproductive risk of elemental metal is less certain than its overall toxicity.Avoid exposure and request substance-specific occupational medical review. CONDITION: Conservative due to systemic toxicity; limited direct reproductive data.
Environmental effectsHighReleases of metal particles or soluble products can threaten aquatic or terrestrial organisms; toxicity depends on speciation and dose.Contain wastewater and particulate residues; follow waste regulations. CONDITION: Never assume elemental metal dissolves at salt-like rates.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierProfessional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment.
Research objectiveMeasure thallium in certified reference material
Expected observation / outputTrace Tl assay, recovery. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified bulk elemental specimen, thin film, certified alloy or reference matrix; never silently substitute a compound.
Sample preparation & apparatusEnclosed instrument or preprepared certified reference; exposure and waste control are prerequisites.
Atmosphere and compatibilitySpecify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter.
Production / refining contextContext: Byproduct of Pb/Zn sulfide refining. For teaching, use certified prepared materials; industrial extraction is not a bench recipe.
Reaction, oxidation & corrosionTl(I) dominates many compounds; chemically resembles K(I); very dense soft metal. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseSelect temperature/pressure only after phase and hazard review; do not assume handbook values for unknown allotropes.
Electrical / magnetic / optical measurementICP-MS for Tl; XRF in some matrices. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationDo not confuse thallium(I) with safe potassium chemistry; lab access limited. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallHighly toxic; do not make an elemental handling exercise.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveCertified containment and segregated inventory with contamination monitoring and disposal protocol.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • specialized controlled professional facility; no open handling
Practical experiment questionMeasure thallium in certified reference material.
Measurable evidenceTrace Tl assay, recovery. Trace/major element concentration in specified matrix.
Measurement pathway (candidate)Certified solid or solution CRM by ICP-MS/XRF as matrix permits.
Specimen & interpretation boundaryHighly toxic; do not make an elemental handling exercise.
Known failure/false conclusionSample heterogeneity, contamination, oxidation, geometry/matrix effects and inadequate calibration range.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteLead
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.