ELEMENT 003 / ALKALI METAL
3LiATOMIC NUMBER · SYMBOL

Lithium

Experimental chemistry • properties • laboratory science

Soft alkali metal; Li(I) dominates; high electrochemical potential and strong solvation effects.

Atomic no. 3Alkali metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERLiReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number3
Symbol / typeLi · Alkali metal • Solid at room temperature • atomic mass: 6.941 (rounded)
Elemental formSolid | selected oxidation states +1
Chemical identitySoft alkali metal; Li(I) dominates; high electrochemical potential and strong solvation effects.
Occurrence and productionBrines and hard-rock spodumene; recovered by chemical conversion and electrolysis for metal.
Useful applicationsLi-ion batteries use lithium compounds; metal is used in specialty cells and synthesis.
Analytical characterizationICP-OES/ICP-MS for Li in materials; XRD for lithium-containing cathodes.
Research / quality noteBattery performance depends on electrode chemistry and microstructure, not elemental lithium alone.
Bench propertiesApprox. melting 180.5 °C; density 0.53 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: +1. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)453.61 K (180.46 °C)
Elemental-bulk boiling / gas formation (near 1 atm)1615 K (1341.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitions?
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-LiSolid (elemental baseline; named form stability can differ)≈453.61 K(180.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1615 K(1341.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Low-temperature rhombohedral phase below the approximately 70.7 K transition at ordinary pressure. LAB: Diffraction distinguishes it from warm metal; not normally retained at room temperature.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~453.61 K; generic gas reference ~1615 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-LiSolid (elemental baseline; named form stability can differ)≈453.61 K(180.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1615 K(1341.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
bcc metallic lithium at ordinary laboratory temperature. LAB: Ordinary bulk crystalline reference form.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~453.61 K; generic gas reference ~1615 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Compressed lithiumSolid (elemental baseline; named form stability can differ)≈453.61 K(180.46 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1615 K(1341.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
fcc and low-symmetry high-pressure structures have been reported. LAB: Requires pressure-resolved XRD; not typical samples. [AL3,AL5]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~453.61 K; generic gas reference ~1615 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 70.7 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Li-6Stable; no observed radioactive decaySolid — ⁶Li metal453.55 K(180.4 °C; ⁶Li metal)≈1615 K(1341.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Stable nuclide; verify current NNDC evaluation
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~453.55 K; liquid between ~453.55 and ~1615 K; gas above ~1615 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Separated isotope of lithium metal; near normal pressure
Evidence level
Measured isotope-specific melting; normal-element mixture boiling is only a reference
Isotope phase source
https://doi.org/10.1103/PhysRev.128.6
Photographs

No photograph added yet.

Li-7Stable; no observed radioactive decaySolid — ⁷Li metal453.85 K(180.7 °C; ⁷Li metal)≈1615 K(1341.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Stable nuclide; verify current NNDC evaluation
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~453.85 K; liquid between ~453.85 and ~1615 K; gas above ~1615 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Separated isotope of lithium metal; near normal pressure
Evidence level
Measured isotope-specific melting; normal-element mixture boiling is only a reference
Isotope phase source
https://doi.org/10.1103/PhysRev.128.6
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Li-8. The BLUE entries refer ONLY to stable nuclides, not to Li-8.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 10 recorded: 3, 4, 5, 6, 7, 8, 9, 10, 11, 12. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateCriticalMetal reacts with moist skin; chemical/thermal burns.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedCriticalRepeated direct contact risks recurrent chemical burns and scarring; elemental lithium is not the same exposure as lithium medicines.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighDust or smoke from burning lithium can irritate or injure the airway; a solid lump does not normally create inhalable exposure.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedHighRepeated dust/smoke exposure can injure airways; specific chronic risks depend on lithium compounds and dose.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighFresh lithium tarnishes as it reacts with oxygen, nitrogen and atmospheric moisture; oxide/nitride/hydroxide coatings form.Interpret together with storage, ignition and process conditions.
Water contactCriticalCold water reacts exothermically, forming lithium hydroxide and flammable hydrogen; usually less violent than Na/K.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionCriticalMetal reacts with saliva/body water, generating heat, caustic hydroxide and hydrogen; chemical burns can be severe.Absolutely prevent ingestion; use inert storage and qualified chemical procedures. CONDITION: Actual severity depends on amount and metal.
Eye exposureCriticalReactive metal particles plus eye moisture can generate caustic hydroxide and heat, causing serious burns.Sealed or inert manipulation by trained staff; high-quality face protection and medical response. CONDITION: Strongly form-dependent.
Skin absorptionCriticalWater on skin reacts with reactive metal and generates heat and strong alkali, causing burns rather than requiring transdermal absorption.No bare skin contact; moisture exclusion and emergency planning. CONDITION: Physical chemical reaction, not systemic skin uptake.
Fire and explosionCriticalReactive metal can ignite after contact with moisture/air; hydrogen generation can trigger fire or explosion.Inert or approved moisture-excluding storage, trained users and a suitable metal-fire plan. CONDITION: Larger pieces differ from dust; Rb/Cs particularly reactive.
Heating and fumesCriticalHeating highly reactive metal can cause ignition and severe fire/caustic injuries.Inert atmosphere and purpose-built controlled apparatus only. CONDITION: Temperature/moisture dependent.
Chemical incompatibilityCriticalStrong incompatibility with water, moist air, acids and many oxidizers; hydrogen, caustic alkali, heat and fire can result.Segregate by written compatibility plan; exclude incompatible extinguishing agents and chemicals. CONDITION: Elemental alkali metal, not its salts or ions.
Storage and pressureCriticalAir/moisture exposure, failed seals or unsuitable storage liquids can cause heat, hydrogen and ignition.Dry compatible inert enclosure and designated segregated storage; inspect seals. CONDITION: Rb/Cs require especially careful moisture exclusion.
BioaccumulationUncertainNo reliable general claim about long-term tissue accumulation can be made for every form of this element.Check chemical species, particulate size, bioavailability and toxicokinetics. CONDITION: Absence of evidence is not evidence of no retention.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsHighMetal spilled into water can generate alkaline solution, heat and hydrogen; acute local aquatic injury and fire risk are possible.Avoid drains, waterways and wet waste; trained hazardous-waste response. CONDITION: Impact varies with spill mass/dilution.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsModerateSoft reactive metal may deform; accidental cutting/contact with moist tools adds chemical/fire hazard.Trained tool use and protected inert handling. CONDITION: Physical handling can trigger chemical reaction.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierTrained controlled atmosphere — Avoid unreviewed demonstrations involving elemental reactive metal.
Research objectiveCompare lithium-containing electrode chemistry with metallic lithium
Expected observation / outputPhase identification, Li content, electrochemical result. Predetermine units, calibration basis and appropriate control.
Available physical formProfessionally sealed elemental specimen; do not confuse with much safer salt standards.
Sample preparation & apparatusCompatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable.
Atmosphere and compatibilityDry inert atmosphere may be essential for bulk elemental specimens; validate oxygen/water levels; no open-air metal handling.
Production / refining contextOccurrence/production context: Brines and hard-rock spodumene; recovered by chemical conversion and electrolysis for metal. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionSoft alkali metal; Li(I) dominates; high electrochemical potential and strong solvation effects. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseScreening context: approx. melt 180.5 °C and density 0.53 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified.
Electrical / magnetic / optical measurementICP-OES/ICP-MS for Li in materials; XRD for lithium-containing cathodes. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationBattery performance depends on electrode chemistry and microstructure, not elemental lithium alone. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallBattery cathodes are lithium compounds, not elemental Li.
Teaching / research levelsSchool: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol.
Preservation & data archiveOnly manufacturer/institution-approved sealed dry containment under expert-controlled storage; check packaging integrity.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • controlled atmosphere and trained staff for elemental specimen
Practical experiment questionCompare lithium-containing electrode chemistry with metallic lithium.
Measurable evidencePhase identification, Li content, electrochemical result. Total element content; a salt assay does NOT prove elemental-metal purity.
Measurement pathway (candidate)ICP-OES/ICP-MS on certified salt/alloy matrix; sealed optical cell if appropriate.
Specimen & interpretation boundaryBattery cathodes are lithium compounds, not elemental Li.
Known failure/false conclusionOxide/moisture growth on elemental surface; seals, contamination and oxidation during transfer.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteBeryllium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: