Overview & practical chemistry
Identity, occurrence, applications and measurement context from the working reference manuscript.
| Atomic number | 80 |
|---|---|
| Symbol / type | Hg · Transition metal • Liquid at room temperature • atomic mass: 200.590 (rounded) |
| Elemental form | Liquid | selected oxidation states +1,+2 |
| Chemical identity | Only common liquid elemental metal near room temperature; readily forms amalgams and volatile vapor. |
| Occurrence and production | Mainly cinnabar processing historically; now recovery/recycling emphasized. |
| Useful applications | Legacy instruments, electrochemistry research and specialty industrial uses. |
| Analytical characterization | Cold-vapor atomic absorption/fluorescence for Hg; vapor monitoring. |
| Research / quality note | Metallic Hg vapor, soluble mercury salts and methylmercury are distinct exposure forms. |
| Bench properties | Approx. melting -38.8 °C; density 13.53 g/cm³ near room temperature. Check phase/purity before design. |
| Oxidation and chemical forms | Selected: +1 / +2. Values depend on compound and chemical environment. |
Phase transitions & temperature reference
Elemental bulk · approximately 1 atmAt approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.
| Phase at 20 °C, ~1 atm | Liquid |
|---|---|
| Elemental-bulk melting / freezing (near 1 atm) | 234.321 K (-38.83 °C) |
| Elemental-bulk boiling / gas formation (near 1 atm) | 629.88 K (356.73 °C) |
| Sublimation (solid → gas) near 1 atm | Not the stable direct phase boundary at 1 atm (melting then boiling) |
| Additional solid–solid transitions | ? |
| Plasma onset temperature | Not a single phase boundary; ionization is density/pressure/energy dependent |
| Measurement conditions | ca. 1 atm; evaluated elemental-bulk reference only |
| Data qualification | NIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review. |
Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.
Allotropes & elemental forms
Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.
| Form / phase | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|
| Documented ordinary/reference form | Liquid (elemental baseline; named form stability can differ) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | |||
Identification and structural context
| Overview | Allotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated. |
|---|---|
| Transition note | No additional independently evaluated ordinary-pressure solid–solid transition temperature is listed here. Absence of a table entry does not prove that no pressure-induced or metastable phases exist. |
| Laboratory identification | Laboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments. |
| Evidence & scope | Evidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented. |
Selected isotopes & radioactivity
This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.
| Nuclide | Half-life | State at 20 °C | Melting / transition | Boiling / sublimation |
|---|---|---|---|---|
| Hg-196 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-198 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-199 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-200 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-201 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-202 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-203 | 46.6 d | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
| Hg-204 | Half-life/status not independently verified here | Liquid (expected elemental chemical form, not isotope-specific observation) | ≈234.321 K(-38.83 °C) (elemental-reference proxy, NOT specific to this isotope/form) | ≈629.88 K(356.73 °C) (elemental-reference proxy, NOT specific to this isotope/form) |
Full record, evidence, conditions & photographs
Photographs No photograph added yet. | ||||
Radiological exposure & interpretation
| Isotope basis | Common elemental specimens include stable isotopes; example *radioactive* isotope: Hg-203. The BLUE entries refer ONLY to stable nuclides, not to Hg-203. |
|---|---|
| External radiation — near-term | Stable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. |
| External radiation — longer-term | Stable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase. |
| Internal exposure — near-term | Stable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. |
| Internal exposure — longer-term | Stable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome. |
Isotope mass-number inventory (reference registry; not complete ENSDF): 40 recorded: 171, 172, 173, 174, 175, 176, 177, 178, 179, 180, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, 195, 196, 197, 198, 199, 200, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.
Human effects & chemical reactions
The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.
Skin contact & inhalation
| Route & duration | Screening | Possible effects | Conditions |
|---|---|---|---|
| Skin contact — immediate | Low | Liquid elemental mercury may not immediately burn intact skin, but it can spread contamination and generate toxic vapor. | Route-specific interpretation only; form, concentration and duration still matter. |
| Skin contact — repeated | Low | Repeated contact with liquid mercury contaminates surfaces; skin reactions are less central than vapor exposure. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — immediate | Critical | Mercury vapor is inhaled at room temperature; higher exposures may cause cough, pneumonitis or delayed lung injury. | Route-specific interpretation only; form, concentration and duration still matter. |
| Inhalation — repeated | Critical | Long-term vapor exposure can injure nervous system and kidneys and cause tremor, mood/cognitive changes. | Route-specific interpretation only; form, concentration and duration still matter. |
Air & water
| Exposure | Screening | Reaction & effect | Interpretation |
|---|---|---|---|
| Air, oxygen and humidity | Critical | Elemental mercury slowly evaporates at room temperature; hazardous vapor can accumulate despite little obvious oxidation. | Interpret together with storage, ignition and process conditions. |
| Water contact | Very low | Liquid mercury does not react chemically with pure water and is poorly soluble; droplets may spread and contaminate surfaces. | Interpret together with storage, ignition and process conditions. |
Twelve additional hazard pathways
Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.
| Hazard | Screening | Possible effect | Practical context |
|---|---|---|---|
| Ingestion | Low | Metallic Hg swallowed as liquid is relatively poorly absorbed by an intact gastrointestinal tract, unlike inhaled Hg vapor; aspiration or retained droplets are dangerous. | Never ingest; prevent spills and hand-to-mouth transfer; mercury-vapor and spill plan. CONDITION: Elemental liquid only, not mercuric salts or methylmercury. |
| Eye exposure | Low | Mercury droplets or contaminated particulates may irritate the eye; the major chronic concern is Hg vapor rather than direct ocular corrosion. | Prevent droplets, aerosols and vapor; control breakage/spill risk. CONDITION: Elemental Hg only. |
| Skin absorption | Low | Absorption through intact skin of elemental liquid mercury is limited relative to vapor inhalation, but skin contamination is unacceptable. | Avoid skin contact and vapor; spill controls; do not equate elemental Hg with organomercury compounds. CONDITION: Elemental mercury, intact skin. |
| Fire and explosion | Low | No usual bulk-element ignition hazard at ambient conditions; other fire hazards from powders or neighboring reagents remain. | Keep away from incompatible reactive chemicals; ensure standard fire protection. CONDITION: Common bulk form. |
| Heating and fumes | Critical | Heating liquid mercury dramatically increases toxic mercury-vapor generation and potential neurologic/kidney injury. | Do not heat in open vessels; certified containment, vapor monitoring and spill planning. CONDITION: Elemental Hg is volatile even at room temperature. |
| Chemical incompatibility | High | Mercury forms amalgams with some metals and can compromise certain metal parts; strong oxidizers and reactive chemicals add hazards. | Use mercury-compatible containment and secondary trays; avoid incompatible metals. CONDITION: Not all common solids are safe containment materials. |
| Storage and pressure | Critical | A broken elemental mercury vessel releases persistent liquid droplets and toxic vapor; small spills are difficult to remove. | Verified leak-tight secondary containment and mercury spill plan; avoid fragile display vessels. CONDITION: Ambient vapor occurs without heating. |
| Bioaccumulation | High | Elemental Hg vapor is absorbed and can accumulate in tissues; environmental methylmercury biomagnification is a DIFFERENT chemical species. | Prevent Hg vapor and spills; distinguish elemental Hg from methylmercury. CONDITION: Do not claim elemental mercury metal itself biomagnifies like methylmercury. |
| Reproductive/developmental effects | Critical | Exposure to elemental Hg vapor may harm the nervous system; fetal/developmental effects depend on form and dose. Methylmercury has distinct, better-characterized developmental risks. | Prevent vapor exposure and distinguish Hg(0) from organic mercury species. CONDITION: Do not combine mercury forms into one exposure estimate. |
| Environmental effects | Critical | Mercury releases can spread in air/soil/water; microorganisms can convert mercury into methylmercury, which bioaccumulates in aquatic food webs. | Never drain-dispose; mercury-specific containment, recovery and hazardous waste pathway. CONDITION: Elemental Hg transforms environmentally; species must be distinguished. |
| Cryogenic effects | Low | A frozen or very cold sample can cause cold-contact injury; Hg chemical toxicity remains a separate hazard. | Avoid bare contact with cold/contaminated objects. CONDITION: No routine cryogenic application. |
| Mechanical and pressure hazards | Moderate | Liquid droplets spread after vessel breakage; glass shards and persistent contamination complicate safe cleanup. | Robust leak-tight secondary containment; do not use fragile open displayware. CONDITION: Chemical and physical hazards overlap. |
Experimental program
Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.
| Laboratory access tier | Professional controlled setting — Avoid amateur generation of vapors/fumes/dust; see institutional risk assessment. |
|---|---|
| Research objective | Assess mercury content in approved reference materials |
| Expected observation / output | Cold-vapor atomic spectroscopy and recovery. Predetermine units, calibration basis and appropriate control. |
| Available physical form | Certified sealed specimen or approved reference material; vapor containment is critical. |
| Sample preparation & apparatus | Enclosed instrument or preprepared certified reference; exposure and waste control are prerequisites. |
| Atmosphere and compatibility | Specify air/humidity or controlled atmosphere explicitly; record oxygen, moisture and exposure time if surface changes matter. |
| Production / refining context | Context: Mainly cinnabar processing historically; now recovery/recycling emphasized. For teaching, use certified prepared materials; industrial extraction is not a bench recipe. |
| Reaction, oxidation & corrosion | Only common liquid elemental metal near room temperature; readily forms amalgams and volatile vapor. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control. |
| Temperature, pressure & phase | Maintain documented temperature and vapor containment; melting/evaporation tests require specialist review. |
| Electrical / magnetic / optical measurement | Cold-vapor atomic absorption/fluorescence for Hg; vapor monitoring. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds. |
| Quantification & verification | Metallic Hg vapor, soluble mercury salts and methylmercury are distinct exposure forms. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition. |
| Important experimental pitfall | Metal vapor and compounds require different exposure assessment. |
| Teaching / research levels | School: safe surrogate/sample image only. University: certified standards and enclosed instrumentation. Research: approved element-specific protocol. |
| Preservation & data archive | Approved tight container with secondary containment, vapor control and material compatibility verification. |
Element video
A general YouTube video for this element can be added in the administration dashboard.
Measurement & verification
Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.
| Experimental access / responsibility | T3 • specialized controlled professional facility; no open handling |
|---|---|
| Practical experiment question | Assess mercury content in approved reference materials. |
| Measurable evidence | Cold-vapor atomic spectroscopy and recovery. Total mercury in validated matrix; ambient Hg vapor as separate measurand. |
| Measurement pathway (candidate) | Professionally controlled cold-vapor atomic absorption/fluorescence. |
| Specimen & interpretation boundary | Metal vapor and compounds require different exposure assessment. |
| Known failure/false conclusion | Vapor loss, adsorption, amalgamation, reagent blanks and species distinctions. |
| Evidence required BEFORE use | Matrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10]. |
| Important limitation | A suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work. |
| Note | Thallium |
Sources & editorial status
Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.
Review: · Last checked: