ELEMENT 008 / NONMETAL
8OATOMIC NUMBER · SYMBOL

Oxygen

Experimental chemistry • properties • laboratory science

O2 is a powerful oxidant; O3 is a more reactive allotrope; oxide formation controls many materials.

Atomic no. 8NonmetalGas at room conditions
Explore profile
IMAGE PLACEHOLDEROReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number8
Symbol / typeO · Nonmetal • Gas at room temperature • atomic mass: 15.999 (rounded)
Elemental formGas | selected oxidation states -2,-1
Chemical identityO2 is a powerful oxidant; O3 is a more reactive allotrope; oxide formation controls many materials.
Occurrence and productionAir separation; electrolysis; medical/industrial gas purification.
Useful applicationsSteelmaking, oxy-fuel processes, medical oxygen and semiconductor oxidation.
Analytical characterizationParamagnetic or electrochemical oxygen analysis; XPS for surface oxides.
Research / quality noteOxygen partial pressure and contamination determine oxidation; LOX is a different hazard regime.
Oxidation and chemical formsSelected: -2 / -1. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmGas
Elemental-bulk melting / freezing (near 1 atm)54.3705 K (-218.7795 °C)
Elemental-bulk boiling / gas formation (near 1 atm)90.2 K (-182.9500 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitionsα-O₂ → β-O₂: 23.89485 K; β-O₂ → γ-O₂: 43.7991 K
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
Dioxygen O2Gas54.3705 K(solid O₂ → liquid)≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Normal two-atom molecule; triplet ground state. LAB: Conventional oxygen gas; cryogenic solid O2 has α, β and γ modifications.
Approximate solid / liquid / gas ranges
This named form changes structure before or around fusion; no single general solid/liquid/gas range. See form-specific transitions and conditions.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
Pressure and thermal history required; phase at 20 °C does not imply the named polymorph is stable
Evidence level
Curated form-specific transition (NIST TN 2312 / literature; check stated conditions)
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Ozone O3Gas — O₃80.7 K(O₃, measured)161.3 K(O₃, normal boiling)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Distinct triatomic molecular allotrope, strongly oxidizing and unstable relative to O2. LAB: Verify by UV/optical methods in enclosed approved systems; O3 is not a solid O2 crystal phase.
Approximate solid / liquid / gas ranges
Named-form specific published reference at ~1 atm: solid below ~80.7 K; liquid between ~80.7 and ~161.3 K; gas above ~161.3 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
O₃ pure allotrope; near normal pressure; decomposes/reacts under many conditions
Evidence level
NIST evaluated allotrope-specific data
Phase data source
https://webbook.nist.gov/cgi/cbook.cgi?ID=C10028156&Mask=4
Photographs

No photograph added yet.

Solid O2 α, β, γ phasesGas (elemental baseline; named form stability can differ)α→β: 23.89485 K; β→γ: 43.7991 K; melting: 54.3705 K≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
α monoclinic below about 23.9 K; β rhombohedral; γ cubic at higher cryogenic temperatures. LAB: Magnetic/orientational ordering differs; NIST transition β→γ about 43.8 K. [AL2,AL3]
Approximate solid / liquid / gas ranges
This named form changes structure before or around fusion; no single general solid/liquid/gas range. See form-specific transitions and conditions.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
Curated form-specific transition (NIST TN 2312 / literature; check stated conditions)
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
Named forms noted in chapterO2 is a powerful oxidant; O3 is a more reactive allotrope; oxide formation controls many materials.
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 23.895 K; β → γ = 43.799 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
O-15122 sGas (expected elemental chemical form, not isotope-specific observation)≈54.3705 K(-218.7795 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta+
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~54.3705 K; liquid between ~54.3705 and ~90.2 K; gas above ~90.2 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Hypothetical/macroscopic sample not feasible for this nuclide. Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

O-16Stable; no observed radioactive decayGas (expected elemental chemical form, not isotope-specific observation)≈54.3705 K(-218.7795 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Stable nuclide; verify current NNDC evaluation
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~54.3705 K; liquid between ~54.3705 and ~90.2 K; gas above ~90.2 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

O-17Stable; no observed radioactive decayGas (expected elemental chemical form, not isotope-specific observation)≈54.3705 K(-218.7795 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Stable nuclide; verify current NNDC evaluation
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~54.3705 K; liquid between ~54.3705 and ~90.2 K; gas above ~90.2 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

O-18Stable; no observed radioactive decayGas (expected elemental chemical form, not isotope-specific observation)≈54.3705 K(-218.7795 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈90.2 K(-182.9500 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Stable nuclide; verify current NNDC evaluation
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~54.3705 K; liquid between ~54.3705 and ~90.2 K; gas above ~90.2 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: O-15. The BLUE entries refer ONLY to stable nuclides, not to O-15.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 17 recorded: 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateVery lowGas not ordinarily skin toxic; liquid oxygen frostbite.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedVery lowNo ordinary chronic skin toxicity of oxygen gas; contact with liquid oxygen can injure tissue and ignite contaminants.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateModerateOxygen enrichment increases fire hazards; breathing pressurized/high-partial-pressure oxygen can cause acute oxygen toxicity.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedHighProlonged high oxygen partial pressures can injure lungs; normal ambient oxygen is necessary for life.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighO2 is an oxidizer; it is present in air and accelerates combustion of compatible fuels rather than burning itself.Interpret together with storage, ignition and process conditions.
Water contactVery lowNo chemical reaction with pure water at ordinary conditions; oxygen dissolves and supports aquatic life.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionLowOrdinary gas exposure is inhalation rather than ingestion; swallowing compressed/liquefied gas or cold liquid may cause physical injury.Use appropriate gas/cryogenic controls; ingestion of gas is not a routine exposure pathway. CONDITION: No nutritional or therapeutic claim.
Eye exposureModerateNormal O2 gas is not corrosive to the eye; oxygen-enriched combustion or splashes of liquid oxygen can injure.Manage oxidizer and cryogenic conditions; normal air/O2 exposure is not ocular poisoning. CONDITION: Indirect physical hazard.
Skin absorptionLowRoom-temperature gas has no ordinary cutaneous uptake causing systemic toxicity; pressurized/liquefied forms can injure by impact or cold.Prevent gas jets and cold-liquid splashes. CONDITION: Not an inhalation safety statement.
Fire and explosionCriticalOxygen is not fuel, but oxygen enrichment markedly increases combustibility and fire severity.Oxygen-clean equipment, prevent oil/grease contamination and enrichment. CONDITION: Oxidizer—not flammable by itself.
Heating and fumesModerateWarming liquefied or pressurized gas can generate rapid expansion/overpressure; oxygen or hydrogen has additional chemical hazards.Pressure relief and cylinder/cryogenic engineering; avoid heating sealed containers. CONDITION: Only if confined/cold/pressurized.
Chemical incompatibilityHighOxygen-rich conditions are incompatible with oils, grease and some organic/combustible materials under pressure or ignition.Use oxygen-clean hardware and exclude oil/grease. CONDITION: O2 is an oxidizer, not fuel.
Storage and pressureHighCompressed or liquefied gas vessels may rupture, leak, displace oxygen or generate rapid cold expansion; reactive gases add toxicity/fire.Use compliant rated cylinders, restraint, compatible regulators, relief devices, ventilation and leak planning. CONDITION: A small unpressurized room-temperature amount is different.
BioaccumulationVery lowThese ordinary gases do not normally bioaccumulate as persistent chemical toxicants; oxygen deprivation/oxidation hazards are separate.Evaluate atmosphere and pressure, not a tissue accumulation model. CONDITION: Radioactive gas isotopes (e.g., Kr-85) are different.
Reproductive/developmental effectsLowNo established reproductive toxicity from normal ambient exposure to the pure gas; severe oxygen depletion or excessive oxygen are separate acute hazards.Control occupational atmosphere and pressure rather than assume a developmental toxicant. CONDITION: Not permission to breathe concentrated gases.
Environmental effectsLowPure common gas has low direct persistence as a toxic aquatic solute, but large releases can alter oxygen availability or fire conditions.Ventilate controlled spaces; environmental release permitting when required. CONDITION: Not equivalent to no occupational danger.
Cryogenic effectsCriticalLiquid oxygen causes cold injury and intense oxygen-enriched fire risk; some materials become dangerously flammable.Oxygen-clean cryogenic equipment, ventilation and correct cryo PPE. CONDITION: Cryogenic LOX, not normal breathing air.
Mechanical and pressure hazardsHighHigh-pressure gas jets/cylinder failure can injure or propel fragments; liquid gases add cold-burn risk.Secure cylinders, approved regulators, guards and release controls. CONDITION: Physical pressure hazard is independent of gas toxicity.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierSupervised apparatus / trained handling — Gas-cylinder, oxygen-deficiency, pressure and/or fume risks require engineered controls.
Research objectiveMeasure oxygen content and distinguish O2 from oxygen dissolved in samples
Expected observation / outputOxygen analyzer response and calibration. Predetermine units, calibration basis and appropriate control.
Available physical formCertified gas in engineered system or factory-sealed optical reference cell, not a loose solid.
Sample preparation & apparatusApproved gas manifold, pressure regulator, gas purity sensor and leak checks; check oxygen-deficiency risk.
Atmosphere and compatibilityKnown gas composition, temperature, regulator condition and chamber pressure; monitor oxygen displacement where relevant.
Production / refining contextOccurrence/production context: Air separation; electrolysis; medical/industrial gas purification. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionO2 is a powerful oxidant; O3 is a more reactive allotrope; oxide formation controls many materials. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseUse regulated pressure/temperature ranges supplied by certified equipment; record flow and gas composition.
Electrical / magnetic / optical measurementParamagnetic or electrochemical oxygen analysis; XPS for surface oxides. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationOxygen partial pressure and contamination determine oxidation; LOX is a different hazard regime. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallElevated oxygen increases combustion risk; concentration matters.
Teaching / research levelsSchool: sealed demonstration/recorded spectra only. University: managed gas analysis. Research: validated gas-phase and surface studies.
Preservation & data archiveApproved cylinder or sealed reference cell, correct segregation, securement and leak checks; no improvised storage.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT2 • closed certified gas/optical system and trained operator
Practical experiment questionMeasure oxygen content and distinguish O2 from oxygen dissolved in samples.
Measurable evidenceOxygen analyzer response and calibration. Gas purity, partial pressure or emission lines.
Measurement pathway (candidate)Calibrated gas analysis or certified sealed optical emission reference.
Specimen & interpretation boundaryElevated oxygen increases combustion risk; concentration matters.
Known failure/false conclusionLeaks, carrier gas purity, pressure, adsorption and detector background; O2 deficiency where relevant.
Evidence required BEFORE useCertified gas/reference lamp certificates + traceable calibration [R11].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteFluorine
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: