ELEMENT 038 / ALKALINE EARTH METAL
38SrATOMIC NUMBER · SYMBOL

Strontium

Experimental chemistry • properties • laboratory science

Sr(II), calcium-like chemistry; compounds produce characteristic red emission.

Atomic no. 38Alkaline earth metalSolid at room conditions
Explore profile
IMAGE PLACEHOLDERSrReal element images to be added later

Click a photograph for a larger view. Images are managed in the editor.

01
The essentials

Overview & practical chemistry

Identity, occurrence, applications and measurement context from the working reference manuscript.

Atomic number38
Symbol / typeSr · Alkaline-earth metal • Solid at room temperature • atomic mass: 87.620 (rounded)
Elemental formSolid | selected oxidation states +2
Chemical identitySr(II), calcium-like chemistry; compounds produce characteristic red emission.
Occurrence and productionCelestite and strontianite; metal by reduction.
Useful applicationsCeramic magnets (ferrites), optical glass and red pyrotechnics.
Analytical characterizationICP-MS for Sr; isotope-ratio MS for source tracing; XRD for ferrites.
Research / quality noteSr-90 is radioactive; ordinary stable strontium and Sr-90 must be separated in reporting.
Bench propertiesApprox. melting 777 °C; density 2.64 g/cm³ near room temperature. Check phase/purity before design.
Oxidation and chemical formsSelected: +2. Values depend on compound and chemical environment.

Phase transitions & temperature reference

Elemental bulk · approximately 1 atm

At approximately 1 atm, bulk values depend on specimen, isotope mixture and phase. When specific measurements or published theoretical estimates exist, they are labeled. A value borrowed from a normal element is only a reference proxy. Plasma is an ionized state, without a single universal onset temperature.

Phase at 20 °C, ~1 atmSolid
Elemental-bulk melting / freezing (near 1 atm)1041 K (767.85 °C)
Elemental-bulk boiling / gas formation (near 1 atm)1650 K (1376.85 °C)
Sublimation (solid → gas) near 1 atmNot the stable direct phase boundary at 1 atm (melting then boiling)
Additional solid–solid transitionsα-Sr → β-Sr: 820 K
Plasma onset temperatureNot a single phase boundary; ionization is density/pressure/energy dependent
Measurement conditionsca. 1 atm; evaluated elemental-bulk reference only
Data qualificationNIST evaluated elemental-bulk solid–liquid transition; verify sample form and pressure. Boiling value comes from a secondary table and remains provisional until primary-source review.

Solid-phase reference: NIST Technical Note 2312 (2025). Boiling data: PubChem (NIH) where checked, otherwise secondary tabulation (provisional). Additional tabulated elemental values were cross-checked with the Royal Society of Chemistry. Where one exists, the named-form reference is not a universally applicable transition. Values can be form-dependent, metastable, estimated or pressure-dependent; verify against original reports for laboratory use.

02
Structure matters

Allotropes & elemental forms

Values are distinguished as form-specific measurements, theoretical predictions, or ELEMENTAL REFERENCE proxies. A numerical proxy describes the natural-element reference, not a measured melting/boiling point of that named form. ? remains where no defensible value or proxy exists.

Form / phaseState at 20 °CMelting / transitionBoiling / sublimation
α-Sr (fcc)Solid (elemental baseline; named form stability can differ)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
Ordinary-pressure room-temperature structure. LAB: Diffraction reference.
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1041 K; generic gas reference ~1650 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

β-Sr (bcc)Solid (elemental baseline; named form stability can differ)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Structure, conditions & interpretation
High-temperature; α→β about 820 K at 1 atm. LAB: Also multiple compressed phases under high pressure. [AL3,AL5]
Approximate solid / liquid / gas ranges
Bulk/form-comparator melting ~1041 K; generic gas reference ~1650 K. NOT a phase range for this named form; it can transform or exist only under special pressure.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Phase conditions
~1 atm elemental baseline. This particular structural form can transform, sublime or decompose before the listed bulk transition.
Evidence level
ELEMENTAL/OTHER-FORM REFERENCE only — NOT this form’s measurement
Phase data source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Identification and structural context
OverviewAllotropy describes structurally different forms made of the same element. Distinguish genuine allotropes from melting/freezing, impurities, compounds, isotopes, size-dependent surface effects and magnetic transitions. “Normal” below means approximately 1 atm unless another pressure is stated.
Transition noteSelected evaluated transitions at ~1 atm (NIST TN 2312): α → β = 820 K. These are phase boundaries, not safe heating instructions.
Laboratory identificationLaboratory identification: compare diffraction or phase-sensitive spectroscopy to reliable standards under recorded pressure, temperature and specimen composition. The described forms do not authorize hazardous synthesis or high-pressure experiments.
Evidence & scopeEvidence & scope: [AL1, AL2, AL3, AL5]. Lists cover established principal named forms and notable experimentally reported polymorphs; an absolutely exhaustive list of all high-pressure, ultrathin, transient, metastable or newly discovered structures is not scientifically fixed. If data are unavailable, this is recorded rather than invented.
03
Nuclear science

Selected isotopes & radioactivity

This is a selected isotope list, not all known nuclides. Exact isotope-specific results are used where documented; elsewhere numerical elemental references are shown only as proxies, never as measurements or calculated isotope-specific estimates. Very short-lived isotopes cannot practically be collected in bulk. Plasma has no universal onset temperature.

NuclideHalf-lifeState at 20 °CMelting / transitionBoiling / sublimation
Sr-84Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1041 K; liquid between ~1041 and ~1650 K; gas above ~1650 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Sr-86Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1041 K; liquid between ~1041 and ~1650 K; gas above ~1650 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Sr-87Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1041 K; liquid between ~1041 and ~1650 K; gas above ~1650 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Sr-88Half-life/status not independently verified hereSolid (expected elemental chemical form, not isotope-specific observation)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
Consult NNDC NuDat / IUPAC IPTEI before citing
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1041 K; liquid between ~1041 and ~1650 K; gas above ~1650 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Sr-9028.8 ySolid (expected elemental chemical form, not isotope-specific observation)≈1041 K(767.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)≈1650 K(1376.85 °C) (elemental-reference proxy, NOT specific to this isotope/form)
Full record, evidence, conditions & photographs
Decay or evidence note
beta-
Approximate solid / liquid / gas ranges
Elemental-reference ranges ONLY, not proven for this isotope at ~1 atm: solid below ~1041 K; liquid between ~1041 and ~1650 K; gas above ~1650 K. Not a plasma threshold.
Plasma onset
Not a fixed temperature — ionization depends on density, pressure and energy input
Pressure / sample conditions
Pure isotope values can differ from natural-element mixture; ~1 atm reference; the elemental form and isotopic enrichment must be specified.
Evidence level
ELEMENTAL/FORM REFERENCE only — NOT an isotope measurement
Isotope phase source
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2312.pdf
Photographs

No photograph added yet.

Radiological exposure & interpretation
Isotope basisCommon elemental specimens include stable isotopes; example *radioactive* isotope: Sr-90. The BLUE entries refer ONLY to stable nuclides, not to Sr-90.
External radiation — near-termStable nuclides emit no nuclear decay radiation; no direct radiological injury from brief contact with the stable-only material. Radioisotope-labelled material is a different case. Specific example: Sr-90 and daughter Y-90 are beta emitters; severe local injury is possible from high-activity skin contamination.
External radiation — longer-termStable-only material causes no cumulative ionizing dose from its own nuclei. For a radioactive isotope, long-term effects depend on measured dose; cancer risk can increase.
Internal exposure — near-termStable-only particles/gases give no internal radionuclide dose. Chemical or asphyxiation risks still apply. A radioactive isotope taken into the body can deliver organ dose. Internal Sr-90 behaves partly like calcium and can be retained in bone, irradiating marrow and bone surfaces.
Internal exposure — longer-termStable-only material has no radiation-driven long-term effect. Inhaled radioisotopes may be retained and increase delayed cancer risk; isotope and chemical form govern the outcome.

Isotope mass-number inventory (reference registry; not complete ENSDF): 33 recorded: 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105. • The nuclide examples are selected reference entries from Volume 1, not an evaluated inventory of every isotope. Original half-life/status data require current nuclear-database checks. Distance alone cannot establish a safe dose.

04
Separate exposure routes

Human effects & chemical reactions

The colored chips are inherited qualitative editorial screening labels, not GHS classifications, measured dose thresholds or permissions to touch or breathe any substance.

Skin contact & inhalation

Route & durationScreeningPossible effectsConditions
Skin contact — immediateHighBulk irritant; reactive fresh surfaces.Route-specific interpretation only; form, concentration and duration still matter.
Skin contact — repeatedHighMetal powder/contact may irritate or chemically burn moist skin; radiostrontium contamination adds a separate hazard.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — immediateHighFresh metal dust can irritate; inhaled Sr-90 can deliver internal radiation without immediate symptoms.Route-specific interpretation only; form, concentration and duration still matter.
Inhalation — repeatedHighChronic risks include respiratory irritation or radionuclide bone dose; stable strontium compounds differ from Sr-90.Route-specific interpretation only; form, concentration and duration still matter.

Air & water

ExposureScreeningReaction & effectInterpretation
Air, oxygen and humidityHighStrontium metal oxidizes in air and reacts with atmospheric moisture; fresh or divided metal is more reactive.Interpret together with storage, ignition and process conditions.
Water contactCriticalReacts with cold water to give Sr(OH)2 and H2; speed depends on surface conditions.Interpret together with storage, ignition and process conditions.
05
Beyond direct exposure

Twelve additional hazard pathways

Ingestion, ocular contact, pressure, fire, heat, incompatibilities, bioaccumulation and other relevant laboratory pathways.

HazardScreeningPossible effectPractical context
IngestionModerateIngestion of elemental particles is not a validated safe exposure; toxicity depends on solubility, amount, particle size and transformations in stomach acid.Prevent hand-to-mouth exposure; use elemental-form SDS for any incident. CONDITION: Screening level only.
Eye exposureModerateSolid fragments, dust or filings can abrade or irritate eyes; no evidence of an ordinary corrosive effect from intact clean bulk metal.Keep material enclosed; use splash/impact-rated eyewear when processing. CONDITION: Physical injury is not the same as systemic toxicity.
Skin absorptionLowNo established substantial systemic absorption through intact skin for clean bulk elemental sample; contamination or damaged skin can change exposure.Basic gloves/hygiene and no intentional skin contact. CONDITION: Low skin uptake does not prove overall harmlessness.
Fire and explosionModerateFreshly divided reactive metal can burn and forms flammable hydrogen with water; bulk samples may react more slowly.Dry, compatible handling; prevent water contact and fire spread. CONDITION: Metal form and moisture govern outcome.
Heating and fumesModerateHeating any element can cause thermal burns; hot particulates, evolved vapor or reaction products may alter toxicity.Determine melting/boiling points and fume chemistry; use local exhaust and thermal PPE. CONDITION: No claim that cold metal produces these fumes.
Chemical incompatibilityHighReactive alkaline-earth metal reacts with water/acids and oxidizers, producing heat and flammable hydrogen.Dry storage and compatibility review; avoid moisture. CONDITION: Finely divided form more active.
Storage and pressureModerateStorage moisture can react with fresh metal and generate flammable hydrogen/alkaline residues.Dry suitable storage and segregation from acids/water. CONDITION: Metal rather than metal salts.
BioaccumulationModerateSome related absorbed ions can distribute with mineral metabolism; sustained accumulation is species- and physiology-dependent.Avoid ingesting reactive metal/soluble compounds; use specific biokinetic data. CONDITION: Do not infer from calcium nutrition.
Reproductive/developmental effectsUncertainInsufficient elemental-form evidence to classify reproductive/developmental toxicity for ordinary laboratory handling.Consult verified CLP/GHS classification and specific SDS; do not substitute metal-compound studies. CONDITION: Unknown is grey, not green.
Environmental effectsModerateEnvironmental hazard depends on weathering, particle size, soluble products and ecosystem exposure; elemental identity alone is insufficient.Collect metal residues and avoid uncontrolled discharge; consult local waste classification. CONDITION: Conservative screening.
Cryogenic effectsLowElement does not ordinarily require cryogenic containment; any object chilled sufficiently can cause frostbite and sealed vessels can fail thermally.Use cryogenic PPE and compatible temperature-rated apparatus only if process actually uses low temperature. CONDITION: No intrinsic hazard at room temperature.
Mechanical and pressure hazardsLowSmall intact pieces present ordinary pinch, cut and glass-breakage risks; cutting, grinding or molten handling increases injury potential.Secure specimen and use physical guards and appropriate PPE. CONDITION: Risk depends more on specimen and task than atom number.
06
From questions to evidence

Experimental program

Candidate investigation plans requiring qualified supervision and method-specific review before laboratory use.

Laboratory access tierTrained controlled atmosphere — Avoid unreviewed demonstrations involving elemental reactive metal.
Research objectiveDetermine strontium content and phase in a standard material
Expected observation / outputICP assay and XRD phase. Predetermine units, calibration basis and appropriate control.
Available physical formSpecified metal versus oxide/salt; verify surface oxide and moisture history.
Sample preparation & apparatusCompatible sealed sample holders with reviewed inert/dry conditions and oxygen/moisture monitoring as applicable.
Atmosphere and compatibilityDry inert atmosphere may be essential for bulk elemental specimens; validate oxygen/water levels; no open-air metal handling.
Production / refining contextOccurrence/production context: Celestite and strontianite; metal by reduction. Compare supply grade, supplier CoA and measured composition before choosing a refining route.
Reaction, oxidation & corrosionSr(II), calcium-like chemistry; compounds produce characteristic red emission. For a reaction or corrosion claim, state the exact phase, reagent, concentration, surface finish and time; compare blank/control.
Temperature, pressure & phaseScreening context: approx. melt 777 °C and density 2.64 g/cm³ (from Volume 2; condition-dependent). Verify by DSC/density method only if justified.
Electrical / magnetic / optical measurementICP-MS for Sr; isotope-ratio MS for source tracing; XRD for ferrites. Confirm the method measures the actual specified elemental form; several listed techniques characterize derivatives or compounds.
Quantification & verificationSr-90 is radioactive; ordinary stable strontium and Sr-90 must be separated in reporting. Record lot/CoA, preparation, blanks, calibration, replicate results, uncertainty and waste disposition.
Important experimental pitfallSr compounds and radioactive Sr-90 require different controls.
Teaching / research levelsSchool: teacher-approved observation or safe comparison. University: quantitative method with controls. Research: advanced instrument and uncertainty study.
Preservation & data archiveUse labeled chemically compatible sealed storage; document surface condition, humidity, atmosphere and any change since measurement.
07
See the science

Element video

Video coming soon

A general YouTube video for this element can be added in the administration dashboard.

08
Reproducible work

Measurement & verification

Choose a method appropriate to the specimen and measurand, then document calibration, controls, uncertainty and interpretation limits.

Experimental access / responsibilityT3 • controlled atmosphere and trained staff for elemental specimen
Practical experiment questionDetermine strontium content and phase in a standard material.
Measurable evidenceICP assay and XRD phase. Specified total element concentration, crystal phase or surface chemistry.
Measurement pathway (candidate)XRF/ICP-OES/ICP-MS for composition; XRD or surface assay only if needed.
Specimen & interpretation boundarySr compounds and radioactive Sr-90 require different controls.
Known failure/false conclusionOxide/moisture growth on elemental surface; seals, contamination and oxidation during transfer.
Evidence required BEFORE useMatrix-matched SRM/CRM + method scope + validation or local verification [R02,R05,R07–R10].
Important limitationA suggested technique is not a validated SOP. Verify exact specimen, measurand, method scope, calibration, blanks, control materials, uncertainty, operator competence and applicable institutional approvals before work.
NoteYttrium
09
Evidence and revision

Sources & editorial status

Scientific review pending

Imported from the prepublication chemistry manuscript. Claim-level scientific review and direct source mapping are not complete. Do not rely on the screening assessments for laboratory safety decisions.

Review: · Last checked: